Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
page 22<br />
fig. 71<br />
protective cap reset button (red)<br />
Stove ON 13:45<br />
NO PeLLetS<br />
O u t p u t < | | | | | | - - - ><br />
Cleaning ash pan (figure 70)<br />
CAUTION! Ash pan can be hot!!<br />
• Remove the base cover front (H1).<br />
• Pull out the ash pan (in a forward direction).<br />
• Empty ash pan and clean ash drawer space.<br />
Vacuum-cleaning ash drawer space<br />
Allow the appliance to cool down completely and use vacuumcleaner only in<br />
combination with an » Ash Box « – Fire hazard!<br />
28. Resetting safety temperature limiter (only with central heating appliances)<br />
fig. 72<br />
27. Error messages / Remedy of defects<br />
NO PeLLetS<br />
NOt igNiteD<br />
If the maximum permissible boiler temperature of 95 °C is exceeded, the safety<br />
temperature limiter, in short STB, is activated and the display shows the error<br />
message StB activateD. After having cooled down, the STB must be reset<br />
<strong>manual</strong>ly (figure 71)<br />
• Remove the base panel of the pellet module.<br />
• Screw off black protective cap and press the red reset button.<br />
• Reset the error message by pressing the button OK .<br />
In the event of an error message the display begins to flash.<br />
Remedy the defect with the aid of the following list of defects and subsequently<br />
confirm the error message. To do so, press and hold the OK button (for approx.<br />
2 seconds) in the top level of the menu.<br />
Display Fault Possible cause Solution<br />
No pellets have been transported/<br />
pellets storage container empty<br />
No ignition /no ignition after<br />
power failure<br />
Container empty Add fuel<br />
Grate dirty Empty ash pan (in operating position StOve OFF)<br />
Conveyor drive Clean auger or contact your service centre<br />
Air regulator open Close air regulator<br />
Insufficient supply of fresh air Ensure permanent supply of fresh air<br />
Ash pan full Empty ash pan (in operating position StOve OFF)<br />
Heating door open Close heating door<br />
Heating damper open Close heating damper<br />
Ash pan full Empty ash pan (in operating position StOve OFF)<br />
Flue opening clogged Clean appliance<br />
Air regulator open Close air regulator<br />
Insufficient supply of fresh air Ensure permanent supply of fresh air<br />
Container empty Add fuel