page 22<br />

fig. 71<br />

protective cap reset button (red)<br />

Stove ON 13:45<br />

NO PeLLetS<br />

O u t p u t < | | | | | | - - - ><br />

Cleaning ash pan (figure 70)<br />

CAUTION! Ash pan can be hot!!<br />

• Remove the base cover front (H1).<br />

• Pull out the ash pan (in a forward direction).<br />

• Empty ash pan and clean ash drawer space.<br />

Vacuum-cleaning ash drawer space<br />

Allow the appliance to cool down completely and use vacuumcleaner only in<br />

combination with an » Ash Box « – Fire hazard!<br />

28. Resetting safety temperature limiter (only with central heating appliances)<br />

fig. 72<br />

27. Error messages / Remedy of defects<br />

NO PeLLetS<br />

NOt igNiteD<br />

If the maximum permissible boiler temperature of 95 °C is exceeded, the safety<br />

temperature limiter, in short STB, is activated and the display shows the error<br />

message StB activateD. After having cooled down, the STB must be reset<br />

<strong>manual</strong>ly (figure 71)<br />

• Remove the base panel of the pellet module.<br />

• Screw off black protective cap and press the red reset button.<br />

• Reset the error message by pressing the button OK .<br />

In the event of an error message the display begins to flash.<br />

Remedy the defect with the aid of the following list of defects and subsequently<br />

confirm the error message. To do so, press and hold the OK button (for approx.<br />

2 seconds) in the top level of the menu.<br />

Display Fault Possible cause Solution<br />

No pellets have been transported/<br />

pellets storage container empty<br />

No ignition /no ignition after<br />

power failure<br />

Container empty Add fuel<br />

Grate dirty Empty ash pan (in operating position StOve OFF)<br />

Conveyor drive Clean auger or contact your service centre<br />

Air regulator open Close air regulator<br />

Insufficient supply of fresh air Ensure permanent supply of fresh air<br />

Ash pan full Empty ash pan (in operating position StOve OFF)<br />

Heating door open Close heating door<br />

Heating damper open Close heating damper<br />

Ash pan full Empty ash pan (in operating position StOve OFF)<br />

Flue opening clogged Clean appliance<br />

Air regulator open Close air regulator<br />

Insufficient supply of fresh air Ensure permanent supply of fresh air<br />

Container empty Add fuel