Multitec BioControl - Combined stationary measuring ... - Sewerin
Multitec BioControl - Combined stationary measuring ... - Sewerin
Multitec BioControl - Combined stationary measuring ... - Sewerin
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
® <strong>Combined</strong> <strong>stationary</strong> <strong>measuring</strong> device<br />
<strong>Multitec</strong> <strong>BioControl</strong> with mobile gas meter
®<br />
<strong>Multitec</strong> <strong>BioControl</strong><br />
Determines the composition and<br />
volume of biogas, sewer gas and<br />
landfill gas<br />
All plant operators producing electricity from biogas, sewer gas<br />
or landfill gas aim to optimise processes and thus ensure greater<br />
efficiency – in other words, obtain as much methane as possible.<br />
At the same time, however, harmful components in the gas need<br />
to be kept to a minimum.<br />
Only constant monitoring of the gas composition in a plant can<br />
indicate changes before it is too late and thereby prevent<br />
prolonged outages. For example, if there is a warning of too<br />
much sulphur at the measurement location before the motor, the<br />
operator can act immediately to stop the motor from being<br />
destroyed.<br />
If the power generation is subsidised, the plant operator must<br />
regularly document the gas composition and volume.<br />
®<br />
The <strong>Multitec</strong> <strong>BioControl</strong> can reliably and sustainably handle<br />
all these tasks, though dirt, deposits, moisture, corrosion and<br />
fluctuating gas compositions still pose a major challenge. The<br />
intelligent compensation of pressure, temperature, moisture and<br />
gas composition means that the components can be analysed<br />
®<br />
with precision. The <strong>Multitec</strong> <strong>BioControl</strong> can also determine<br />
the temperature and flow rate.<br />
System drawing<br />
One of up to eight<br />
measurement locations:<br />
· Fermenter<br />
· Secondary fermenter<br />
· In front of motor<br />
· In front of/after<br />
desulphuriser<br />
· etc.<br />
Gas pipe<br />
®<br />
<strong>Multitec</strong> <strong>BioControl</strong><br />
Flow rate<br />
Flow rate and<br />
temperature <strong>measuring</strong> device<br />
Power supply<br />
24 V DC<br />
Communication output<br />
e.g.<br />
· Profibus<br />
· Lan<br />
· Internet via wired<br />
network or UMTS
®<br />
<strong>Multitec</strong> <strong>BioControl</strong><br />
One system for <strong>stationary</strong> and mobile measurements<br />
® ®<br />
The <strong>Multitec</strong> <strong>BioControl</strong> is a combined <strong>measuring</strong> device consisting of the <strong>Multitec</strong> <strong>BioControl</strong> fixed installation and a mobile<br />
®<br />
gas <strong>measuring</strong> device, namely the <strong>Multitec</strong> 540.<br />
®<br />
Depending on the version of <strong>Multitec</strong> <strong>BioControl</strong> , the gas composition and volume can be automatically measured and monitored<br />
®<br />
at up to eight measurement locations. The <strong>Multitec</strong> 540 measures the values at the individual measurement locations sequentially.<br />
®<br />
The values are transferred to the <strong>Multitec</strong> <strong>BioControl</strong> via an interface.<br />
®<br />
The mobile gas <strong>measuring</strong> device must be regularly maintained to guarantee accurate <strong>measuring</strong> results. The <strong>Multitec</strong> <strong>BioControl</strong><br />
allows easy maintenance for the versions with four and eight measurement locations as standard, with automatic calibration and<br />
adjustment with test gas.<br />
®<br />
The <strong>Multitec</strong> <strong>BioControl</strong> fixed installation is non-wearing and low maintenance. All that is required is a regular check for dirt on the<br />
flow rate and temperature sensor and cleaning if necessary. This can be done in a few minutes whilst <strong>measuring</strong>. The mobile<br />
® <strong>Multitec</strong> 540 gas <strong>measuring</strong> device can be easily sent in for servicing. A spare device prevents disruption to operation.<br />
Mobile measurements<br />
Individual <strong>measuring</strong> locations can also be set<br />
up for mobile, i.e. manual measurement if<br />
®<br />
preferred. The <strong>Multitec</strong> 540 is simply taken<br />
®<br />
out of the <strong>Multitec</strong> <strong>BioControl</strong> docking<br />
station for the measurement. When it is<br />
replaced in the docking station following a<br />
mobile measurement, the stored logs are<br />
®<br />
transferred to the <strong>Multitec</strong> <strong>BioControl</strong> and<br />
displayed.<br />
Mobile measurements allow you to integrate<br />
even remote outdoor <strong>measuring</strong> points reliably<br />
and cost-effectively in the system. ATEXcertified<br />
flow rate and temperature transmitters,<br />
which can be permanently installed outdoors,<br />
are available as optional accessories.<br />
Measurement ranges / resolutions<br />
Flow rate<br />
Temperature<br />
Measuring range<br />
0 – 30 Nm/s<br />
18.8 – 1000 mm<br />
Features<br />
· Large colour touch screen<br />
· Custom configuration according to<br />
requirements specification<br />
· All settings password-protected<br />
· Continuous self-testing throughout<br />
operation<br />
· All relevant components resistant to<br />
aggressive gases<br />
· Autonomous and regular saving of all<br />
measurement values and settings<br />
on USB stick<br />
· Remote maintenance and diagnostics<br />
available via Internet<br />
0 – 70 °C, equivalent to 0.5 – 30.8 % vol.<br />
Resolution / comment<br />
Compensated <strong>measuring</strong> range<br />
Adjustable diameter<br />
Product variants<br />
Compensated <strong>measuring</strong> range<br />
®<br />
· <strong>Multitec</strong> <strong>BioControl</strong>.1<br />
®<br />
· <strong>Multitec</strong> <strong>BioControl</strong>.4<br />
®<br />
· <strong>Multitec</strong> <strong>BioControl</strong>.8<br />
The number at the end of the<br />
product name indicates the<br />
maximum number of<br />
measurement locations that can<br />
be connected as part of the<br />
installation.
®<br />
<strong>Multitec</strong> 540 as a mobile gas <strong>measuring</strong> device<br />
®<br />
The <strong>Multitec</strong> 540 is a gas <strong>measuring</strong> device for monitoring<br />
gas mixtures that are formed in biological processes. It can<br />
measure the concentration of up to five gases in the gas mixture<br />
simultaneously. The device is fitted with infrared sensors for<br />
<strong>measuring</strong> methane and carbon dioxide as standard. It can also<br />
be fitted with electrochemical sensors.<br />
The use of infrared <strong>measuring</strong> technology for methane and<br />
carbon dioxide eliminates erroneous results caused by<br />
®<br />
interaction with other gases. The <strong>Multitec</strong> 540 is, therefore,<br />
ideal for use in biogas plants as well as waste disposal sites and<br />
sewage plants. A large screen allows all parameters to be<br />
displayed simultaneously and quickly read off at a glance.<br />
Features<br />
· Intuitive, menu-driven user interface with jog dial and<br />
function keys<br />
· Large transflective, i.e. semi-transparent display, excellent<br />
readability, even in direct sunlight<br />
· Selective infrared sensors for hydrocarbons and<br />
carbon dioxide<br />
· Highly durable electrochemical sensors for oxygen and<br />
toxic gases<br />
· Power supplied by four replaceable AA-size rechargeable<br />
batteries or disposable batteries<br />
· Minimum seven hour battery life in operation,<br />
rapid charging in four hours<br />
· Explosion protection: II2G Ex d e ib IIB T4 Gb /<br />
II2G Ex d e Ib IIC T4 Gb with TG8 carrying bag<br />
· EC type-examination certificate: TÜV 07 ATEX 553353 X<br />
Measuring range and sensors<br />
Gas type<br />
Methane<br />
Carbon dioxide<br />
Oxygen<br />
Hydrogen sulphide<br />
Carbon monoxide<br />
106944 – 08/12<br />
Subject to technical changes.<br />
Measuring range<br />
0.0 – 100 % vol.<br />
0 – 100% vol.<br />
0.0 – 25 % vol.<br />
0 – 2000 ppm<br />
0 – 500 ppm<br />
Sensor type<br />
Infrared sensor<br />
Infrared sensor<br />
Electrochemical sensor<br />
Electrochemical sensor<br />
Electrochemical sensor<br />
Please contact us for a comprehensive quotation, including additional<br />
technical specifications and information on accessories.<br />
Hermann <strong>Sewerin</strong> GmbH | Robert-Bosch-Straße 3 | D-33334 Gütersloh<br />
Phone +49 5241 934-0 | Fax +49 5241 934-444 | www.sewerin.com | info@sewerin.com<br />
RLWA-BI 010532011 GB