14.05.2013 Views

Steam Atomising Burner DDZ - Saacke.com

Steam Atomising Burner DDZ - Saacke.com

Steam Atomising Burner DDZ - Saacke.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Steam</strong> <strong>Atomising</strong> <strong>Burner</strong><br />

<strong>DDZ</strong><br />

Capacity 9.5 - 55 MW<br />

Fuel oil Heavy Fuel Oil up to 700 cSt/50 °C<br />

Marine Diesel Oil<br />

Marine Gas Oil<br />

Fuel gas Natural gas standard and all others on<br />

demand, e.g. natural gas from well<br />

Turn down ratio 1:8 for burners up to 12 MW<br />

1:10 for burners from 12 - 23 MW<br />

1:15 for burners > 23 MW<br />

Design Features The SAACKE steam atomising burner is designed for firing medium and<br />

large sized water tube boilers such as auxiliary and main boilers for<br />

tankers and FPSOs.<br />

The unique SAACKE-design features staged <strong>com</strong>bustion air supply and<br />

distribution. This allows a high turn down ratio and ensures <strong>com</strong>plete<br />

<strong>com</strong>bustion, resulting in low 0 2 values even when operating on low load.<br />

At the same time, a very stable flame over the whole load range is given.<br />

On account of its highly versatile flame geometry, the <strong>DDZ</strong> burner is<br />

equally suitable for side fired and top fired boilers.<br />

The fuel-air ratio is controlled by an electronic <strong>com</strong>pound regulator in<br />

<strong>com</strong>bination with a PLC <strong>com</strong>bustion controller. A mechanical <strong>com</strong>pound<br />

regulator can be supplied on demand.<br />

For FPSOs and LNG carrier applications this burner is available as a<br />

<strong>com</strong>bined oil and gas burner, of type <strong>DDZ</strong>G.


© SAACKE GmbH · February 2011 (R/5) · Content subject to alteration.<br />

<strong>Steam</strong><br />

DN 12<br />

Fuel oil<br />

DN 15<br />

MS<br />

<strong>Burner</strong> type max.<br />

capacity*<br />

MW<br />

<strong>DDZ</strong> 10-325 9.5<br />

<strong>DDZ</strong> 10-345 11.3<br />

<strong>DDZ</strong> 10-365 13<br />

<strong>DDZ</strong> 10-400 16<br />

<strong>DDZ</strong> 10-425 18.5<br />

<strong>DDZ</strong> 10-450 21.5<br />

<strong>DDZ</strong> 12-475 23<br />

<strong>DDZ</strong> 12-500 26<br />

<strong>DDZ</strong> 12-530 30<br />

<strong>DDZ</strong> 12-560 34<br />

<strong>DDZ</strong> 14-600 36<br />

<strong>DDZ</strong> 14-630 41<br />

<strong>DDZ</strong> 14-670 47.5<br />

<strong>DDZ</strong> 14-710 55<br />

* for application at D-type boilers<br />

** minimal length<br />

*** depends on actual burner design<br />

**** without <strong>com</strong>bustion air fan<br />

F<br />

(free mounting space)<br />

Lm**<br />

mm<br />

E<br />

A<br />

mm<br />

Lm2<br />

B<br />

mm<br />

SAACKE GmbH · Südweststrasse 13 · 28237 Bremen · Germany · Phone: +49 - 421 - 64 95 0 · eMail: marine@saacke.de<br />

www.saacke-marine-systems.<strong>com</strong><br />

C<br />

mm<br />

E<br />

mm<br />

F<br />

mm<br />

MS***<br />

mm<br />

<strong>Burner</strong><br />

weight****<br />

kg<br />

250 1180 800 1250 700 776 2000 800<br />

300 1450 1000 1300 900 1016<br />

3000<br />

350 1900 1400 1750 1100 1170 3750 1600<br />

Air inlet<br />

flange<br />

A<br />

<strong>DDZ</strong><br />

1100<br />

B<br />

C