07.05.2013 Views

1b 1a 8a 3 6 7a 5 2a 7b 2b 8b 4

1b 1a 8a 3 6 7a 5 2a 7b 2b 8b 4

1b 1a 8a 3 6 7a 5 2a 7b 2b 8b 4

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>1a</strong><br />

<strong>1b</strong><br />

3 4<br />

5<br />

6<br />

Remove old gasket<br />

Only if mounted with 0,9 (net). Disassemble,<br />

clean and reassemble with new net.<br />

<strong>7a</strong><br />

If no GFC/GFB<br />

Annual Maintenance of Pres-Vac Valves Maintenancekit A for vacuum side of valve.<br />

Only if mounted with 0,9 (net)<br />

Place new O-ring<br />

DO NOT<br />

dissasemble<br />

Vac-seat/housing<br />

and weight.<br />

Do not clean in<br />

ultrasonic bath.<br />

<strong>7b</strong><br />

Only if mounted with<br />

GFC/GFB<br />

Only if mounted with 0,65 (filter)<br />

Place new O-ring<br />

Remove old O-ring<br />

Inspect and clean<br />

<strong>2a</strong><br />

If no GFC/GFB<br />

<strong>8a</strong><br />

Only if mounted with 0,9 (net)<br />

Remove old O-ring<br />

<strong>2b</strong><br />

Remove old O-ring<br />

<strong>8b</strong><br />

Only if mounted with 0,65 (filter)<br />

Only if mounted<br />

with GFC/GFB<br />

Place new gasket<br />

Place new O-ring<br />

Warning: Do not clean in ultrasonic bath


Annual Maintenance of Pres-Vac Valves Maintenancekit A for pressure side of valve.<br />

1<br />

Before work lift top and<br />

protect the seat with a<br />

cloth.<br />

The cloth must remain<br />

on top of the seat,<br />

throughout the<br />

dissembly, cleaning and<br />

assembly.<br />

Remove the cloth before<br />

adjusting procedure.<br />

5<br />

9<br />

13<br />

Remove old O-rings<br />

Mount lockwasher, adjust<br />

screw, nut and split.<br />

2<br />

6<br />

10<br />

14<br />

Remove old O-ring<br />

Unscrew and remove inner<br />

magnet part.<br />

Cap is mounted for adjustment.<br />

Mount new O-rings<br />

After adjustment, remove<br />

cap and lock the<br />

lockwasher.<br />

Remount cap.<br />

3<br />

7<br />

11<br />

Unscrew inspection<br />

plug<br />

and remove old<br />

gasket<br />

Mount new O-ring<br />

Adjusting the opening pressure:<br />

After overhaul, adjustment of the relief pressure is needed.<br />

The relief pressure adjusting mechanisms are adjustable within<br />

the span given<br />

for the approved Configuration.<br />

For this operation, a PRES-VAC Test Rig is recommended.<br />

For further instructions, look in the manual.<br />

Lift and remove top unit<br />

from housing.<br />

Inspect and clean top<br />

unit and housing.<br />

Screw and remount inner<br />

magnet part.<br />

4<br />

8 Oiler<br />

Replace O-Ring<br />

12<br />

Replace oiler<br />

Grease lifter<br />

Adjustment is done as described below:<br />

• Unlock the lock washer, and unscrew the nut<br />

• To increase the opening pressure setting, turn the adjusting<br />

screw clock-wise<br />

• To decrease the opening pressure setting, turn the adjusting<br />

screw<br />

counter-clock-wise<br />

• Remount the lock washer, mount the nut and lock the lock<br />

washer again.<br />

Warning: Do not clean in ultrasonic bath