Table L9: 281 RSA-KwaZulu Development Project infrastructure options for the upgrading of existing areas, and for the establishment of new black (urban) residential sites and towns in NatailKwaZulu, 1990. Development Water supplies Sanitation Bus routes Streets ElectricitY Refuse option 1 Vending through VIP or VIDP Gravel roadway, Tracks, surveyed None (can be Central skip water kiosks or latrine as open drains, road reserves, no provided later if system metered standpipe necessary levelled walkways formal drains, required - 1,5 vending points. (only if practical) crossflow, kVA connection Spacing as per site waterbars. On plus 12 street requirements land steeper than lights km-', (approximately one a gradient of source every 250 1 : 2,5 pedestrian m) access only - road within 250 m of house 2 Vending through VIP or VIDP Gravel roadway, Gravel roadway, None (can be Central skip water kiosks or latrine as open drains, levelled provided later if system metered standpipe necessary levelled walkways walkways, required - 1,5 vending points. (only if practical) combination of kVA connection Spacing as per site open drains in plus 12 street requirements areas of excessive lights km-') (approximately one stormwater source per 10 accumulation residential sites) (lined or unlined), and no drains (crossfall) in others
Table L9: 282 RSA-KwaZulu Development Project infrastructure options for the upgrading of existing ereas, and for the establishment of new black (urbanl residential sites and towns in Natal/KwaZulu, 1990 (continued). Development Water supplies Sanitation Bus routes Streets Electricity Refuse option 3 Vending through VIP or VIDP Gravel roadway, Gravel roadway, None (can be Central skip water kiosks or latrine as open drains, levelled provided later if system or door metered standpipe necessary levelled walkways walkways, required· 1,6 to door vending points. (only if practical) combination of kVA connection collection Spacing as per site open drains in plus 12 street requirements areas of excessive lights km-') (approximately one stormwater source per 10 accumulation residential sites) (lined or unlined), and no drains (crossflow) in others 4 Metered standpipe VIP or VIOP Paved roadway, Gravel roadway, 1,5 kVA Central skip on site. Owner to latrine or suitable levelled walkways levelled connection plus system or door pay for connection alternative (paved if walkways, 12 street lights to door from property on site, wet required), combination of km-' collection boundary to disposal sanitation kerb/channel or grassed and lined standpipe system as lined open drains open drains, no (including meter necessary crossflow assembly and standpipe), and to provide a soakpit as required
- Page 236 and 237: 232 • Vegter, J.R., 1995. Groundw
- Page 238 and 239: 234 • Meyer, R. and Godfrey, l.,
- Page 240 and 241: Springs 236 • Africa Co-operative
- Page 242 and 243: NOTES: 238
- Page 244 and 245: 239 CHAPTER 12: WATER SUPPLY PLANNI
- Page 246 and 247: 12.1 Introduction 241 111'1&111111
- Page 248 and 249: 243 rilliltl.'ll water consumption
- Page 250 and 251: Table L2: Cattle 245 study of reduc
- Page 252 and 253: Note: (j) (ii) (iii) 247 Animal wat
- Page 254: 249 111111:llllltJI Source: After A
- Page 257 and 258: 1111111118.1 252 Table L4: Some per
- Page 259 and 260: lillll.'.II' 254 high income. Iow d
- Page 261 and 262: * 256 to obtain. Difficulties inclu
- Page 263 and 264: 1111...11 (iii) 258 Home Glasson Pa
- Page 265 and 266: 260 Table L6: Some typical domestic
- Page 267 and 268: * ** 262 are in agreement with cons
- Page 270 and 271: Table L7: Some South African indust
- Page 272 and 273: Table L7: 267 Some South African In
- Page 274 and 275: Table L7: 269 Some South African in
- Page 276 and 277: Table L7: 271 Some South African In
- Page 278 and 279: Note: (i) (ii) (iii) (iv) (v) (vi)
- Page 281 and 282: 276 concentrate on the provision of
- Page 283: 278 Table L8: RSA-KwaZulu Developme
- Page 288 and 289: Table L9: 283 RSA-KwaZulu Developme
- Page 291 and 292: 286 the Green book, namely, Anonymo
- Page 293 and 294: IIIRlmlllillS 12.4.2 Durban Metro W
- Page 296: 291 design phase of projects. Any a
- Page 299 and 300: 294 Table L12: Some extant water wh
- Page 301: 11111111111911 296 • Energy Resea
- Page 304 and 305: 299 11111111111111 Table l13: Speci
- Page 306: 301 Table L13: Specific training ag
- Page 309 and 310: 304 Road and Umlazi (Durban); Pinet
- Page 312: 307 Table L14: A spatial typology o
- Page 315 and 316: 310 Table L15: A typology of social
- Page 317: 1111111..11 312 Table L15: A typolo
- Page 320 and 321: 315 114,[llll1\'1 Table L16: Some s
- Page 322 and 323: 317 Table L18: Mean household size
- Page 324 and 325: 319 Illil;JJtllllll Table L19: Exis
- Page 326 and 327: 321 Table L19: Existing housing del
- Page 328 and 329: 323 1IIIi!:lil.'11 a month, and a s
- Page 330 and 331: NOTES: 325
Table L9:<br />
281<br />
RSA-KwaZulu Development Project infrastructure options for the upgrading <strong>of</strong> existing areas, and for the establishment<br />
<strong>of</strong> new black (urban) residential sites and towns in NatailKwaZulu, 1990.<br />
Development Water supplies Sanitation Bus routes Streets ElectricitY Refuse<br />
option<br />
1 Vending through VIP or VIDP Gravel roadway, Tracks, surveyed None (can be Central skip<br />
water kiosks or latrine as open drains, road reserves, no provided later if system<br />
metered standpipe necessary levelled walkways formal drains, required - 1,5<br />
vending points. (only if practical) crossflow, kVA connection<br />
Spacing as per site waterbars. On plus 12 street<br />
requirements land steeper than lights km-',<br />
(approximately one a gradient <strong>of</strong><br />
source every 250 1 : 2,5 pedestrian<br />
m) access only - road<br />
within 250 m <strong>of</strong><br />
house<br />
2 Vending through VIP or VIDP Gravel roadway, Gravel roadway, None (can be Central skip<br />
water kiosks or latrine as open drains, levelled provided later if system<br />
metered standpipe necessary levelled walkways walkways, required - 1,5<br />
vending points. (only if practical) combination <strong>of</strong> kVA connection<br />
Spacing as per site open drains in plus 12 street<br />
requirements areas <strong>of</strong> excessive lights km-')<br />
(approximately one stormwater<br />
source per 10 accumulation<br />
residential sites) (lined or unlined),<br />
and no drains<br />
(crossfall) in<br />
others