Installing New Hardware Components<br />

Note: Always observe anti-static<br />

precautions when handling electronic<br />

equipment.<br />

↓ Installing new DSP or I/O cards<br />

↓ Installing new I/O modules<br />

INTRODUCTION TO THE HURON<br />

New <strong>Huron</strong> cards and modules can be purchased to expand the<br />

capability of <strong>Huron</strong>. Qualified service personnel should<br />

perform the installation of these cards or modules.<br />

These guidelines should be followed when installing new cards:<br />

Addition and removal of all cards should only be attempted<br />

when the power to the <strong>Huron</strong> system is off. When installing a<br />

<strong>Huron</strong> ADAT I/O card, this should be installed in slot 0 (the<br />

leftmost slot when viewing the <strong>Huron</strong> from the front). When<br />

installing a new DSP or I/O carrier card, install it in the slot<br />

directly next to the last <strong>Huron</strong> DSP or I/O card. There should<br />

be no vacant slots between <strong>Huron</strong> DSP and I/O cards.<br />

Addition and removal of all modules should only be attempted<br />

when the power to the <strong>Huron</strong> system is off. When installing<br />

new I/O modules onto a <strong>Huron</strong> I/O carrier card, the position and<br />

orientation of the modules is very important. Input modules are<br />

always populated in module 8 first, followed by module 7, and<br />

so on. Output modules are always populated in module 1 first,<br />

followed by module 2, and so on. When inserting a new input<br />

module insert it in the highest available slot number. When<br />

inserting a new output module, insert it in the lowest available<br />

slot number. Always be careful to ensure the correct orientation<br />

of any modules. The orientation shown in Figure 4 must be<br />

adhered to for all modules. Special attention must also be paid<br />

to ensuring the module connector pins mate perfectly with the<br />

I/O base card connectors. Incorrect insertion of the modules<br />

could result in damage to the module and/or the workstation.<br />

HURON TECHNICAL MANUAL PAGE 30