↓ To select the type of filter to be<br />
used by the Convolver<br />
Filter<br />
Type<br />
Number<br />
Filter<br />
Lengths in<br />
Taps<br />
Latency in<br />
Milliseconds<br />
THE ENGINEERING TOOLS<br />
Each filter type provides a method of accessing and utilising the<br />
DSP resources of the <strong>Huron</strong> system. Filters play off latency,<br />
length and the number of buffers available within the Convolver<br />
tool with the DSP resources in the system.<br />
1. Click the located to the right of the Filter Type Box.<br />
2. Select the appropriate filter from the drop down menu.<br />
Latency in<br />
Samples<br />
Number of DSP<br />
resources used<br />
per channel<br />
Number of<br />
Buffers available<br />
0 2058 0.02ms 1 1 3<br />
1 34728 0.06ms 3 2 3<br />
2 139010 0.10ms 5 3 3<br />
3 278244 0.10ms 5 3 1<br />
4 4319 1.00ms 46 1 3<br />
5 69422 1.00ms 48 2 3<br />
6 8638 2.00ms 92 1 2<br />
7 138924 2.00ms 94 2 2<br />
8 277988 4.00ms 187 2 1<br />
9 16384 20.00ms 968 1 15<br />
10 32768 41.00ms 1967 1 15<br />
11 65536 82.00ms 3937 1 7<br />
12 131072 166.00ms 7948 1 3<br />
13 262144 336.00ms 16110 1 1<br />
Tip: A single Convolver can only use<br />
one type of filter. To have a system<br />
using different types of filters, simply<br />
invoke more instances of the<br />
Convolver from the VRack.<br />
Creating Programs<br />
↓ To create a program<br />
Table 1 — Filters available to the Convolver<br />
The list contains the number assigned by Lake to the filter type,<br />
the length of the filter in samples, its latency in samples (ie.<br />
how many samples delay there is between data arriving at the<br />
filter and leaving the filter), its latency expressed in<br />
milliseconds (assuming a 48kHz sample rate), the number of<br />
DSP processors this filter uses when running and the number of<br />
buffers, or concurrent programs which can be held in memory<br />
to allow fast switching.<br />
The Convolver calls a collection of filter structures a Program.<br />
Up to 512 of these Programs can exist within the Convolver,<br />
however only one will be active at a time.<br />
1. Click on Add in the Program List.<br />