<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />
Until Reset: This option will display the message until a Master Reset command is sent or<br />
the Reset button is pressed<br />
Timed: Display message for a fixed time duration<br />
Display time & date when expired<br />
Check this option if it is desired to display the time & date during standby. If this option is not<br />
selected the display will be blank during standby.<br />
Font Selection<br />
Message<br />
Normal: Standard height and width<br />
Full Height: For multiple line displays the height is adjusted to the full height of the display<br />
Wide: Characters displayed slightly wider than the standard font<br />
Double Wide: Characters displayed double the standard width<br />
Type the message to display in the Message box .For maximum attention getting keep messages<br />
short and to the point.<br />
Manual Activation<br />
After selecting Manual Activate from the Activation Hotkeys window, the following screen is<br />
displayed. This selection is used to manually activate, send a SmartMsg, or send a DTMF or<br />
Duotone encode.<br />
Send Status<br />
This list box displays the actual commands as they are sent out to the siren sites. It will also<br />
show if the command was acknowledged by the RTU (individual sites only). Note:<br />
Acknowledgment is proof that a remote RTU received the activation command, but not that the<br />
siren is actually running and working correctly. The site must be polled to obtain a report of<br />
actual site conditions.<br />
90<br />
Activate