<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />
Displays the function running at the time of the last poll. If no function is running, STANDBY is<br />
displayed.<br />
Last Function RTU<br />
Displays the last function sounded by this RTU. The status of latched sensors (current, rotation,<br />
pressure, failed to sound) reflects the conditions of the siren as a result of the Last Function. If<br />
not function has sounded since a Master Reset, Standby will be displayed.<br />
Last Function Base<br />
Displays the last function activated by the base.<br />
Note: If the Last Function base is not „Standby‟, a Failed to Sound alarm will be asserted if one of<br />
the following conditions is met:<br />
1. Last Function Base and Last Function RTU do not agree<br />
2. The times disagree by more than 90 minutes<br />
RTU Time<br />
During each poll, the RTU‟s time clock is synchronized with the base computer or SS2000D. The<br />
current setting of the RTU‟s embedded clock is reported back to the base before this update<br />
occurs. This allows the system administrator to monitor the system time clock synchronization.<br />
The RTU Time should normally be within a few minutes of the base station's time during the last<br />
poll. If not, a possible synchronization problem exists. It is important to maintain system time<br />
clock synchronization. RTU‟s that are out of the time sync window (90 minutes) will not sound.<br />
Anytime the time synchronization becomes more than 45 minutes out of agreement, a Sync Fail<br />
alarm will be logged.<br />
MCP Type Status Detail<br />
If the selected RTU is a MCP or UltraVoice type siren, the following Status Detail screen will be<br />
displayed<br />
157<br />
RTU