SFCD: Federal Commander Digital System - Federal Signal
SFCD: Federal Commander Digital System - Federal Signal
SFCD: Federal Commander Digital System - Federal Signal
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />
Each selection in this window will cause the CCU to initiate one or more messages to the<br />
currently selected RTU. In each case, the CCU will wait for an acknowledgment from the RTU, for<br />
the number of seconds programmed for Retry Delay on the Status of Base Unit window. If the<br />
RTU does not respond within the Retry Delay time period, and if the retries field on the Status of<br />
Base Unit window is greater than one, the CCU will resend the message again to the same RTU.<br />
The CCU will continue to attempt to send the requested message until either the RTU<br />
acknowledges the message or until the maximum number of retries has been reached.<br />
Clear Counters<br />
This selection clears the activation and cancel counters for this RTU.<br />
RTU General Parameters<br />
This selection sends the following items from the RTU General Parameters screen:<br />
Program<br />
Alarms - Enabled/Disabled.<br />
Power Fail Detect - Enabled/Disabled.<br />
Trunking Mode - Enabled/Disabled.<br />
Front Porch - Dead carrier time before data transmission.<br />
<strong>SFCD</strong>WARE revision information.<br />
This selection sends the RTU it's personality data including the following information:<br />
Configuration data from the Configure RTU window of Configure RTU Parameters.<br />
Program data from the Program RTU window of Configure RTU Parameters.<br />
Zone configuration information from the Zone window of Base Status.<br />
Electronic siren tone data table.<br />
152<br />
RTU