SFCD: Federal Commander Digital System - Federal Signal
SFCD: Federal Commander Digital System - Federal Signal SFCD: Federal Commander Digital System - Federal Signal
following execution of the ARM function. AMP Zone Control (AZ): Federal Commander Digital System Click on the check box to disable or enable the desired amp. A check indicates that this amp will be enabled. Note: All amplifiers default to enabled following execution of the ARM function. For zoning purposes the audio outputs of the auxiliary audio/relay board are combined with Amp14-Amp16. REPEAT START –n Enter the desired number of times to repeat and click on OK. All functions between REPEAT START and REPEAT END will repeat n times. The repeat function requires RTU uvh v7.2 or greater. Warning: Do not attempt to use the repeat functions on legacy RTUs! REPEAT END Repeat all functions between REPEAT START and REPEAT END n times. 146 RTU
Federal Commander Digital System The repeat function requires RTU uvh v7.2 or greater. Warning: Do not attempt to use the repeat functions on legacy RTUs! Add button and spin control The Spin Control (arrow buttons) selects the next or previous program entry. Add adds a new program entry. Note: Changes made to the programming are saved by clicking on the Save menu item. If the dialog is closed without saving, changes will not be saved. Upload from RTU Clicking on this radio button will cause SFCDWARE to transmit a request for the RTU to upload it's programming information. When this information is received, the information displayed in the Program dialog will reflect that of the RTU. This is a useful tool for verifying the programming at the RTU is correct. Click on Save if it is desired to update the SFCDWARE database. Clicking on Exit will close the dialog without updating database. Delete This selection will delete the currently displayed program. Delete All This selection will delete all programs currently in the database. A warning message will appear. Click OK to continue and delete all programs or Cancel to abort the deletion process. Save This selection will close the Program dialog and save the programs currently displayed. Note: It is necessary to send the Program block command to the RTU before changes will take effect at the respective RTU. Exit This selection will close the Program dialog box without updating database. A warning box will appear. Click continue to terminate the program dialog (all edits will be lost). Click Cancel to abort the exit process. Note: Changes made to the programming are saved by clicking on the Save menu item. If the dialog is closed without saving, changes will not be saved. For FC type RTUs: 147 RTU
- Page 95 and 96: Federal Commander Digital System Th
- Page 97 and 98: Mode Federal Commander Digital Syst
- Page 99 and 100: System Setup Federal Commander Digi
- Page 101 and 102: Federal Commander Digital System To
- Page 103 and 104: Federal Commander Digital System Th
- Page 105 and 106: Federal Commander Digital System in
- Page 107 and 108: Federal Commander Digital System ad
- Page 109 and 110: Federal Commander Digital System ot
- Page 111 and 112: Federal Commander Digital System Th
- Page 113 and 114: Federal Commander Digital System ac
- Page 115 and 116: Voice Modem Comm Port Federal Comma
- Page 117 and 118: Save Federal Commander Digital Syst
- Page 119 and 120: Federal Commander Digital System
- Page 121 and 122: Federal Commander Digital System Th
- Page 123 and 124: Introduction Federal Commander Digi
- Page 125 and 126: Federal Commander Digital System Nu
- Page 127 and 128: IO Board Federal Commander Digital
- Page 129 and 130: RTU Federal Commander Digital Syste
- Page 131 and 132: Quit Federal Commander Digital Syst
- Page 133 and 134: Front Porch Federal Commander Digit
- Page 135 and 136: Federal Commander Digital System re
- Page 137 and 138: Federal Commander Digital System Al
- Page 139 and 140: Correct the problem and Save again.
- Page 141 and 142: DELAY REPEAT START POWER DIGITAL VO
- Page 143 and 144: Activation Functions: PA OUTPUT Fed
- Page 145: RELAY #4 OFF Federal Commander Digi
- Page 149 and 150: Federal Commander Digital System Fo
- Page 151 and 152: Delete Message: Delete All RTU butt
- Page 153 and 154: Poll This RTU Federal Commander Dig
- Page 155 and 156: Federal Commander Digital System Th
- Page 157 and 158: Federal Commander Digital System Di
- Page 159 and 160: Voltage Federal Commander Digital S
- Page 161 and 162: Notepad Federal Commander Digital S
- Page 163 and 164: displayed. Last Function RTU Federa
- Page 165 and 166: Name Column Federal Commander Digit
- Page 167 and 168: Record Checkbox Federal Commander D
- Page 169 and 170: Federal Commander Digital System Co
- Page 171 and 172: Federal Commander Digital System Th
- Page 173 and 174: Federal Commander Digital System 17
- Page 175 and 176: Federal Commander Digital System 17
- Page 177 and 178: Federal Commander Digital System 3.
- Page 179 and 180: Federal Commander Digital System 11
- Page 181: Federal Commander Digital System 3.
<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />
The repeat function requires RTU uvh v7.2 or greater. Warning: Do not attempt to use the repeat<br />
functions on legacy RTUs!<br />
Add button and spin control<br />
The Spin Control (arrow buttons) selects the next or previous program entry. Add adds a new<br />
program entry.<br />
Note: Changes made to the programming are saved by clicking on the Save menu item. If the<br />
dialog is closed without saving, changes will not be saved.<br />
Upload from RTU<br />
Clicking on this radio button will cause <strong>SFCD</strong>WARE to transmit a request for the RTU to upload<br />
it's programming information. When this information is received, the information displayed in the<br />
Program dialog will reflect that of the RTU. This is a useful tool for verifying the programming at<br />
the RTU is correct. Click on Save if it is desired to update the <strong>SFCD</strong>WARE database. Clicking on<br />
Exit will close the dialog without updating database.<br />
Delete<br />
This selection will delete the currently displayed program.<br />
Delete All<br />
This selection will delete all programs currently in the database. A warning message will appear.<br />
Click OK to continue and delete all programs or Cancel to abort the deletion process.<br />
Save<br />
This selection will close the Program dialog and save the programs currently displayed. Note: It<br />
is necessary to send the Program block command to the RTU before changes will take effect at<br />
the respective RTU.<br />
Exit<br />
This selection will close the Program dialog box without updating database. A warning box will<br />
appear. Click continue to terminate the program dialog (all edits will be lost). Click Cancel to<br />
abort the exit process.<br />
Note: Changes made to the programming are saved by clicking on the Save menu item. If the<br />
dialog is closed without saving, changes will not be saved.<br />
For FC type RTUs:<br />
147<br />
RTU