DTMF (optional) Federal Commander Digital System If this is a DTMF type code, enter the DTMF digits for this function here. Acceptable DTMF digits are: 0-9, A, B, C, D, *, #. Note: The DTMF selection is only applicable on systems that use DTMF signaling. Duotone (optional) If this is a tone type code, enter the A Tone and B Tone frequencies for this function here. The acceptable frequency range is 280-3000 Hz. Note: The duotone selection is only applicable on systems that use duotone signaling. EAS Event (optional) For units using EAS/SAME decoding, allows an EAS Event (EEE) code to be associated with this activation function. For EAS activation, the following two conditions must be valid: 1. The location code of the transmitted EAS message matches one of the three programmed location codes (see Config RTU). 2. The EVENT code of the transmitted EAS message matches an event code assigned to an activation code. Note: EAS and Duotone activation is mutually exclusive. For EAS activation to be functional, the Duotone Timing parameters (A-Time, B-Time, S-Time) must be set to zero. Function Two list boxes handle setting up the function sequence. The Function Select box contains a list of available functions. To add a function highlight the desired function and click the Add->> button. The new function will be inserted after the selected (highlighted) item in the Function box. Functions will be executed in sequence and in the order they appear in the list. To remove a function highlight the desired function and click the Remove button. Click Remove All to remove all functions. Arm and Function timers All sounding functions and relays outputs will automatically turn off when the RTU becomes disarmed. Upon reception of the ARM function the RTU will remain armed for 255 seconds. The disarm timer is halted during sounding functions and resumes during the DELAY function or at the end of the function sequence. It is good practice to start each function sequence with an ARM and end with a DISARM. Each individual function is limited to 255 seconds duration. The following functions consume two slots: 140 RTU

DELAY REPEAT START POWER DIGITAL VOICE-n (only if n > 16) The following function consumes three slots: Federal Commander Digital System AMP/AUDIO ZONE All other functions consume one of the 20 available slots. Available Functions Utility Functions: ARM Arms the siren. The siren must be armed or activation functions will not operate. Once armed, the siren will remain armed for approximately 4 ½ minutes. The ARM function will also perform the following: 1. Set Phasing to off (PHASE OFF). 2. Set power output to maximum (HIGH POWER MODE) 3. Set amp zoning to all amps enabled. DISARM Disarms the siren REPORT Send unit status to base. MASTER RESET Terminates active function and clears latched status. PLUS PHASE All functions between “PLUS PHASE” and “MINUS PHASE” will repeat for the duration of time encoded in the EAS activation frame (EAS activations only). MINUS PHASE All functions between “PLUS PHASE” and “MINUS PHASE” will repeat for the duration of time encoded in the EAS activation frame (EAS activations only). PHASE OFF Turn off minus and plus phase and return siren to omni directional mode. LOW POWER MODE Reduce unit power to approximately one watt. 141 RTU

DELAY<br />

REPEAT START<br />

POWER<br />

DIGITAL VOICE-n (only if n > 16)<br />

The following function consumes three slots:<br />

<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />

AMP/AUDIO ZONE<br />

All other functions consume one of the 20 available slots.<br />

Available Functions<br />

Utility Functions:<br />

ARM<br />

Arms the siren. The siren must be armed or activation functions will not operate. Once armed,<br />

the siren will remain armed for approximately 4 ½ minutes. The ARM function will also perform<br />

the following:<br />

1. Set Phasing to off (PHASE OFF).<br />

2. Set power output to maximum (HIGH POWER MODE)<br />

3. Set amp zoning to all amps enabled.<br />

DISARM<br />

Disarms the siren<br />

REPORT<br />

Send unit status to base.<br />

MASTER RESET<br />

Terminates active function and clears latched status.<br />

PLUS PHASE<br />

All functions between “PLUS PHASE” and “MINUS PHASE” will repeat for the duration of time<br />

encoded in the EAS activation frame (EAS activations only).<br />

MINUS PHASE<br />

All functions between “PLUS PHASE” and “MINUS PHASE” will repeat for the duration of time<br />

encoded in the EAS activation frame (EAS activations only).<br />

PHASE OFF<br />

Turn off minus and plus phase and return siren to omni directional mode.<br />

LOW POWER MODE<br />

Reduce unit power to approximately one watt.<br />