DTMF (optional)<br />
<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />
If this is a DTMF type code, enter the DTMF digits for this function here. Acceptable DTMF digits<br />
are: 0-9, A, B, C, D, *, #. Note: The DTMF selection is only applicable on systems that use DTMF<br />
signaling.<br />
Duotone (optional)<br />
If this is a tone type code, enter the A Tone and B Tone frequencies for this function here. The<br />
acceptable frequency range is 280-3000 Hz. Note: The duotone selection is only applicable on<br />
systems that use duotone signaling.<br />
EAS Event (optional)<br />
For units using EAS/SAME decoding, allows an EAS Event (EEE) code to be associated with this<br />
activation function. For EAS activation, the following two conditions must be valid:<br />
1. The location code of the transmitted EAS message matches one of the three<br />
programmed location codes (see Config RTU).<br />
2. The EVENT code of the transmitted EAS message matches an event code assigned to<br />
an activation code.<br />
Note: EAS and Duotone activation is mutually exclusive. For EAS activation to be functional, the<br />
Duotone Timing parameters (A-Time, B-Time, S-Time) must be set to zero.<br />
Function<br />
Two list boxes handle setting up the function sequence. The Function Select box contains a list<br />
of available functions. To add a function highlight the desired function and click the Add->><br />
button. The new function will be inserted after the selected (highlighted) item in the Function box.<br />
Functions will be executed in sequence and in the order they appear in the list. To remove a<br />
function highlight the desired function and click the Remove button. Click Remove All to remove<br />
all functions.<br />
Arm and Function timers<br />
All sounding functions and relays outputs will automatically turn off when the RTU becomes<br />
disarmed. Upon reception of the ARM function the RTU will remain armed for 255 seconds. The<br />
disarm timer is halted during sounding functions and resumes during the DELAY function or at<br />
the end of the function sequence. It is good practice to start each function sequence with an<br />
ARM and end with a DISARM.<br />
Each individual function is limited to 255 seconds duration.<br />
The following functions consume two slots:<br />
140<br />
RTU