IO Board<br />
<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />
The IO Board setup screen allows digital inputs and relay outputs to be associated with hotkeys<br />
for interfacing to third party equipment. Note: The IO Board requires additional steps to be taken<br />
during installation to be functional. It is important that IO Board functionality be tested after<br />
installation to verify correct operation.<br />
Use IO Board<br />
Select this option only when the computer is equipped with an IO Board and the special<br />
installation steps have been performed.<br />
IO Board disabled or not present<br />
Select this option if it is desired to disable the IO Board or the <strong>Commander</strong> computer is not<br />
equipped with the IO Board option.<br />
Inputs<br />
Each of the eight inputs may be associated with a hotkey or disabled. When associated with a<br />
hotkey an active input will cause the respective hotkey to activate as if the hotkey were clicked.<br />
An active input is defined as voltage detected on the input (5 – 28V) for a period of 500 ms.<br />
Outputs<br />
Similar to inputs relay outputs may be associated with a hotkey or disabled. When associated<br />
with a hotkey the relay will close for the duration specified (in seconds) when the respective<br />
hotkey is clicked. All relays will clear if another hotkey activation occurs that is not programmed<br />
to close the relay even if the duration has not yet expired.<br />
127<br />
<strong>System</strong> Setup