<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />

new time to use as the Start Time, then point & click the Save radio button to save the new Callout<br />

Start Time.<br />

The <strong>SFCD</strong>WARE <strong>System</strong> uses this time value (along with End Time) to determine when to<br />

activate and deactivate the Call-out function. When the current time is equal to or greater than<br />

Start Time, and Call-out is enabled, Call-out will be made active.<br />

Alarm Call-out End Time (End Time)<br />

The format of this data entry field is HH:MM, and any valid military time between 00:01 and 23:59.<br />

Leading zeros are required. To change the End Time, highlight the current end time, type in the<br />

new time to use as the End Time, then point & click the Save radio button to save the new Callout<br />

End Time.<br />

The <strong>SFCD</strong>WARE <strong>System</strong> uses this time value (along with Start Time) to determine when to<br />

activate and deactivate the Call-out function. When the current time is equal to or greater than<br />

End Time, Call-out is made inactive.<br />

Alarm Call-out Time Delay (Time Delay Before Callout)<br />

This selection applies for both weekday and weekend.<br />

The format of this data entry field is any number between 0 and 999. To change the Time Delay,<br />

highlight the current delay time, type in the new number of minutes to use as the delay, then point<br />

& click on the Save radio button to save the new number.<br />

This Call-out setup option determines how many minutes an alarm must be present without<br />

clearing before the <strong>SFCD</strong>WARE <strong>System</strong> will originate a Call-out operation.<br />

Alarm Setup<br />

Alarm Setup is used for configuration of Alarms. Alarms are automatic activations scheduled to<br />

occur on a daily, weekly or monthly basis. Holiday mode allows the normally scheduled alarm<br />

time and function to be overridden on selected holidays. Up to 60 alarms may be configured.<br />

Note: This dialog should only be used by specially trained administrative personal. Incorrect<br />

settings in this section could cause sirens to inadvertently sound when not desired.<br />

116<br />

<strong>System</strong> Setup