Alarm Setup Federal Commander Digital System Displays a dialog for configuration of Alarms. Alarms are activation commands scheduled to occur on a daily, weekly or monthly basis. Sound Setup This selection displays a dialog for configuration of system sounds. System sounds are attention getting signals sounded in response to alarms and other events. Email Setup Displays the Email Setup dialog. SmartMsg Setup This selection displays a dialog for configuration of the SmartMsg connection parameters and System Log filter. System Fail Displays the System Fail setup dialog. Save Select this menu item to save any changes and close the Status of Base window. Quit Select this radio button to quit the Status of Base window without saving changes. AVAILABLE DATA ENTRY FIELDS: Communication: Channel SFCDWARE supports up to four communication channels. Each channel is assigned a Mode and Com Port number (if applicable). Utilizing multiple channels allows SFCDWARE to support multiple communication modes. It is important to remember the following limitations when using multiple channels: Mode Codespear mode is limited to channel #1 The Com Port setting must be unique for all channels (do not share com ports) Data is received and sent to all channels simultaneously. Selects the type of communication interface SFCDWARE uses to communicate with the sirens. The available selections are: 1. SS2000 2. Modem 3. Codespear (Codespear) 4. Tetra 5. SkyWave 100 System Setup

Federal Commander Digital System To change the current selection, point & click on the radio button; each time the radio button is pushed, the display will scroll through the possible options, one at a time. The following features are dependant on the Mode selection: PA (VOIP): Only available when Mode = Codespear or Modem DTMF and Duotone Encode: Only available when Mode = Modem Communication Port The Communication Port selection is available only for “SS2000” and “Modem” modes. This setup option determines which serial port on the SFCDWARE computer will be used to interface with the SS2000D or modem that is used to communicate with the RTUs. The possible options are COM1, COM2, COM3, and COM4. To change the current selection, point & click on the radio button; each time the radio button is pushed, the display will scroll through the possible options, one at a time. Front Porch Time The Front Porch Time selection is available only for “Modem” mode. Front Porch is the dead time between transceiver PTT (Push To Talk) and the start of data transmission (0 – 9999 ms). Number of Communication Retries This setup option determines how many times the CCU will try to contact an RTU before considering the communication attempt to be a Comm Fail. The CCU will wait between tries the number of seconds indicated by Retry Delay. Retires may be set to a minimum of 1 and a maximum of 3. To change the number of retries, point & click on the radio button. Each time the radio button is pushed, the display will rotate to the next higher number, up to a max. of 3, at which point the numbers will restart at 1. Retry Delay This setup option determines how many seconds to wait between attempts to contact an RTU. For Program commands 10 seconds will automatically be added to the retry delay. This will prevent the lengthy program command from causing a Com Fail. The format of this data entry field is from 1 to 99 seconds. To change the Retry Delay, highlight the current retry delay number and enter a new number. The setting of this parameter is dependent on the radio system infrastructure, however 10 is an optimum setting for most systems. CCU Address This setup option assigns the CCU site address. The valid address range is 900-909. Primary CCU sites are 900-904 and secondary CCU sites are 905-909. 101 System Setup

Alarm Setup<br />

<strong>Federal</strong> <strong>Commander</strong> <strong>Digital</strong> <strong>System</strong><br />

Displays a dialog for configuration of Alarms. Alarms are activation commands scheduled to<br />

occur on a daily, weekly or monthly basis.<br />

Sound Setup<br />

This selection displays a dialog for configuration of system sounds. <strong>System</strong> sounds are attention<br />

getting signals sounded in response to alarms and other events.<br />

Email Setup<br />

Displays the Email Setup dialog.<br />

SmartMsg Setup<br />

This selection displays a dialog for configuration of the SmartMsg connection parameters and<br />

<strong>System</strong> Log filter.<br />

<strong>System</strong> Fail<br />

Displays the <strong>System</strong> Fail setup dialog.<br />

Save<br />

Select this menu item to save any changes and close the Status of Base window.<br />

Quit<br />

Select this radio button to quit the Status of Base window without saving changes.<br />

AVAILABLE DATA ENTRY FIELDS:<br />

Communication:<br />

Channel<br />

<strong>SFCD</strong>WARE supports up to four communication channels. Each channel is assigned a Mode and<br />

Com Port number (if applicable). Utilizing multiple channels allows <strong>SFCD</strong>WARE to support<br />

multiple communication modes. It is important to remember the following limitations when using<br />

multiple channels:<br />

Mode<br />

Codespear mode is limited to channel #1<br />

The Com Port setting must be unique for all channels (do not share com ports)<br />

Data is received and sent to all channels simultaneously.<br />

Selects the type of communication interface <strong>SFCD</strong>WARE uses to communicate with the sirens.<br />

The available selections are:<br />

1. SS2000<br />

2. Modem<br />

3. Codespear (Codespear)<br />

4. Tetra<br />

5. SkyWave<br />

100<br />

<strong>System</strong> Setup