<strong>Implementer</strong> Conversion<br />

Control Properties<br />

Description<br />

Generating and Configuring the Conversion Properties File<br />

mks.implementer.dr.issue_type Defines the <strong>MKS</strong> Integrity issue type to use for DRs, for example,<br />

Defects.<br />

mks.implementer.sr.issue_type Defines the <strong>MKS</strong> Integrity issue type to use for SRs, for example,<br />

Features.<br />

Design Request and Service Request Field Conversion<br />

Properties and Definitions<br />

Referring to the table on page 448, the field definitions for the design request and service<br />

request conversion properties are as follows:<br />

mks.implementer.dr and mks.implementer.sr indicate whether this field is part of<br />

a design request or service request.<br />

intmgrfield is the <strong>MKS</strong> Integrity field to contain the converted DesignTracker data for<br />

a specific DesignTracker field.<br />

In the following example, the <strong>MKS</strong> Integrity field Priority contains the converted<br />

requester priority for a DR<br />

mks.implementer.dr.intmgrfield.requester_priority=Priority<br />

value is the value to assign in <strong>MKS</strong> Integrity that replaces the value in DesignTracker<br />

In the following example, the <strong>MKS</strong> Integrity field Priority uses the new values of High<br />

for A, Medium for B, and Low for C:<br />

mks.implementer.dr.value.requester_priority.A=High<br />

mks.implementer.dr.value.requester_priority.B=Medium<br />

mks.implementer.dr.value.requester_priority.C=Low<br />

NOTE<br />

The initial <strong>MKS</strong> Integrity field values specified in the conversion properties file<br />

come from the description of the value in DesignTracker. Alternately, you can<br />

edit the description in DesignTracker and recreate the conversion properties file.<br />

For more information, see the table on page 438.<br />

Any spaces in DesignTracker values automatically translate to an underscore “_”<br />

in the value entry. Because this file is built from master files, if any values used in<br />

the DesignTracker database are not listed in the master file, you need to add<br />

those values. If the values contain blanks, you must substitute an underscore for<br />

the blanks. Underscore values are not required when specifying the new<br />

<strong>MKS</strong> Integrity value.<br />