Chapter 4: Remote Distribution Concepts and Setup<br />

172<br />

2 Change the <strong>Implementer</strong> Communications User (IMCMNUSR) data area to blanks by<br />

issuing the following command:<br />

CHGDTAARA DTAARA(<strong>MKS</strong>IM/IMCMNUSR) VALUE(' ')<br />

where VALUE is defined by a blank character enclosed in single quotes. This allows using<br />

the communications entry defined next.<br />

3 Create a mode description on the host system that corresponds to the mode description<br />

on the remote. This allows you to specify the amount of activity needed for<br />

<strong>Implementer</strong>-related activities. Issue the following command:<br />

CRTMODD MODD(IMPMODD) TEXT('<strong>Implementer</strong> Mode')<br />

4 Associate the mode description with the communications subsystem. The default user<br />

profile on the communications entry is the profile that all <strong>Implementer</strong> APPC jobs run<br />

under. You can specify any user profile—a common entry is QUSER.<br />

a) To display the device description and determine the current modes used by the<br />

device, issue the following command:<br />

DSPDEVD DEVD(APPC-device)<br />

b) Change the APPC device description by issuing the following command:<br />

CHGDEVAPPC DEVD(APPC-device)<br />

MODE(existing-modes IMPMODD)<br />

For example, the command for APPC device RMTDEV using mode BLANK is:<br />

CHGDEVAPPC DEVD(RMTDEV) MODE(BLANK IMPMODD)<br />

Remote System Setup<br />

Before starting this task, you must have the name of the communications subsystem on the<br />

remote system. This is normally subsystem QCMN and is referred to as qcmn in the following<br />

instructions. In addition, you must have the name of the APPC device that connects the<br />

remote system to the host. This is referred to as APPC-device in the following instructions.<br />

To perform setup on the remote system<br />

1 Add a communications entry by issuing the following command:<br />

ADDCMNE SBSD(qcmn)<br />

DEV(*APPC)<br />

JOBD(IMPRCV/IMPJOBD)<br />

DFTUSR(MWIPROD)<br />

MODE(IMPMODD)<br />

2 Create a mode description on the remote system that corresponds to the mode<br />

description on the host system. This allows you to specify the amount of activity needed<br />

for <strong>Implementer</strong>-related activities. Issue the following command:<br />

CRTMODD MODD(IMPMODD) TEXT('<strong>Implementer</strong> Mode')