Measurement methods<br />

humidity. The only exception is a vapour-barrier ensemble, which has clothing adjustments<br />

that depend on the level of humidity. In this case, a protective value in the range is suitable.<br />

Table 3 provides CAFs for the ensembles in the current study plus two others from related<br />

work.<br />

Table 3. Clothing Adjustment Factors (CAF) for Five Clothing Ensembles over Base<br />

Clothing (tee shirt/sports bra, shorts with briefs, socks and shoes)<br />

Ensemble Work Cotton Tyvek NexGen Tychem QC<br />

Clothes Coveralls Coveralls Coverall Coveralls<br />

CAF [°C-WBGT] 0 0 0.7 2.5 10.0<br />

In conclusion, Equations 1 and 2 represent a starting point for using WBGT with adjustments<br />

for clothing and metabolic rate. The protective nature of the limit needs to be further<br />

explored for other metabolic rates.<br />

ACKNOWLEDGMENTS<br />

This research was supported by a grant from the US National Institute for Occupational<br />

Safety and Health (1R01 OH03983); and its contents are solely the responsibility of the<br />

authors and do not necessarily represent the official views of NIOSH or the CDC.<br />

493