Environmental Ergonomics XII<br />

Igor B. Mekjavic, Stelios N. Kounalakis & Nigel A.S. Taylor (Eds.), © BIOMED, Ljubljana <strong>2007</strong><br />

corresponds to the increased heat loss due to the cooling, and was therefore used to define the<br />

heat loss in the conditions investigated. However, for the analysis only the maximum P value<br />

was used since in the future the PCG will be equipped with continuous water supply.<br />

Measurement for each condition investigated was repeated three times. The measurements<br />

were performed in a climatic chamber where the environmental temperature and relative<br />

humidity were kept at 20 ±1°C and 50 ±3%, respectively. The mean wind speed was 0.74<br />

±0.02 m/s (MiniAir2, Schiltknecht, Gossau, Switzerland).<br />

With the use of the heating cylinder, we investigated the heat loss (i) when the thinner or the<br />

thicker membrane contacted the air, (ii) when the fit of PCG on the surface of the manikin<br />

changed, and (iii) when different fabrics were placed over the PCG. To investigate the effect<br />

of placing different fabrics over the PCG one synthetic (80% polyester and 20%<br />

polyurethane) and two cotton fabrics distinctive by their thickness were used. Furthermore,<br />

with the use of the anatomically formed manikin, we investigated the heat loss of a pants and<br />

a shirt (Figure 2A), manufactured from PCG and tailored to fit the manikin. Heat loss was<br />

investigated while the manikin was standing still and wore pants and shirt made of PCG.<br />

Furthermore, when the manikin was either standing still or was walking (2.5 km/h) with<br />

clothing typically for female (Figure 2B) or male (Figure 2C) were placed over the PCG. All<br />

clothing was 100% cotton and there was no additional layer between the manikin and the<br />

PCG and the PCG and the clothing.<br />

A B C<br />

Figure 2 The clothing ensemble manufactured from the PCG (A), and the female (B) and<br />

male (C) clothing as used on the manikin.<br />

Statistics: According to the data, the statistical analysis was performed with either a Student ttest<br />

or ANOVA, where a Tukey test for post hoc comparisons was used if a significant<br />

difference was found (p < 0.05).<br />

RESULTS<br />

With placing the thicker membrane in contact with the air, the heat loss significantly<br />

(p