For the correct value please refer to the electric motor supplier’s catalogue (classes CEI 2–3/IEC34-1). The start<br />
up torque must not exceed the gearboxes maximum torque. The number of start-up per hour and the hours of<br />
operation per day must be carefully considered. If the output velocity is constantly less than 1 rpm, there may be<br />
problems with the lubrication of the output stage, which could reduce the calculated theoretical life. In this case it<br />
is advised that you contact the <strong>Jahns</strong> personnel for a proper selection.<br />
class<br />
<strong>Jahns</strong> waives all responsability of improper use of the selection criteria mentioned above, in particular for all<br />
applications subject to special rules and regulations (for example when personal safety is involved) and places this<br />
responsability on the application constructor. It is recommended that the constructor contact <strong>Jahns</strong> technical<br />
department for all such technical support.<br />
2.2 Verifi cations<br />
Gearbox output support:<br />
For each gearbox the dynamic radial loads according to ISO 281 for a duration of L10 corresponding to n2 h =<br />
100.000 are shown in the diagrams.<br />
For different durations, applicable radial loads can be obtained by multiplying the values in the diagrams by the<br />
correction factor kf.<br />
With regards to eventual axial loads, one must ensure that they do not exceed the maximum allowed values.<br />
www.jahns-<strong>hydraulik</strong>.de<br />
duration with<br />
Teq