<strong>CONTACTRON</strong><br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> <strong>and</strong><br />

<strong>motor</strong> management


<strong>CONTACTRON</strong> –<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> <strong>and</strong><br />

<strong>motor</strong> management<br />

Maximum availability <strong>and</strong> optimal productivity<br />

are preconditions for the competitiveness of<br />

an industrial system. The short cycle times<br />

required for this <strong>and</strong> optimal maintenance<br />

cycles can often no longer be realized by<br />

conventional <strong>motor</strong> control systems with<br />

mechanical <strong>contactors</strong>.<br />

<strong>CONTACTRON</strong> solid-<strong>state</strong> <strong>contactors</strong> from<br />

<strong>Phoenix</strong> <strong>Contact</strong> are the durable <strong>and</strong> costsaving<br />

alternative to contactor technology.<br />

<strong>CONTACTRON</strong> power electronics are used<br />

everywhere where frequent, reliable <strong>and</strong><br />

wear-free switching is dem<strong>and</strong>ed.<br />

<strong>CONTACTRON</strong> –<br />

Added value for your system<br />

1. <strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> switch quickly <strong>and</strong><br />

wear-free – that lowers maintenance costs<br />

<strong>and</strong> increases productivity.<br />

2. The <strong>motor</strong> manager has overload <strong>and</strong><br />

underload detection in one device. That not<br />

only protects the <strong>motor</strong>, but also the system<br />

– without complex sensor systems.<br />

3. Motor managers <strong>and</strong> solid-<strong>state</strong> <strong>contactors</strong><br />

can be ideally combined to form fast, costsaving<br />

<strong>and</strong> durable <strong>motor</strong> controls – if<br />

necessary, also with a fieldbus connection.<br />

2 PHOENIX CONTACT


Fast <strong>and</strong> wear-free<br />

switching<br />

The advantages of the <strong>CONTACTRON</strong><br />

ELR 1 <strong>and</strong> ELR 3 solid-<strong>state</strong> contactor<br />

series are ruggedness, long-term<br />

stable switching times <strong>and</strong> a practically<br />

unlimited service life, otherwise not<br />

achieved by mechanical <strong>contactors</strong>.<br />

This makes it ideal for applications with<br />

high switching frequencies, such as heating<br />

controls, lighting systems <strong>and</strong> controlling of<br />

1- <strong>and</strong> 3-phase <strong>motor</strong>s up to 18.5 kW.<br />

Lighting control system<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> provide the high switching<br />

frequencies <strong>and</strong> highly precise switching times<br />

required for professional lighting systems.<br />

4 PHOENIX CONTACT<br />

Plastic injection molding systems<br />

High production quality for plastic injection<br />

molding requires a constant temperature in the<br />

heating zones <strong>and</strong> exact regulation by means<br />

of frequent switching on <strong>and</strong> off. <strong>Solid</strong>-<strong>state</strong><br />

<strong>contactors</strong> can fulfill this switching task reliably<br />

<strong>and</strong> long-term.


<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> offer many<br />

advantages<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> switch wear-free –<br />

that lowers maintenance costs.<br />

Productivity increased by short <strong>and</strong> stable switching<br />

times.<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> are suitable<br />

for use in harsh environments.<br />

Long service life <strong>and</strong> built-in<br />

protective circuit prevent<br />

downtime.<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> can be<br />

directly controlled by the PLC.<br />

Machine tools<br />

The space-saving “4 in 1” solid-<strong>state</strong> reversing<br />

<strong>contactors</strong> are excellently suited for <strong>motor</strong>s<br />

in auxiliary drives, e.g. coolant pumps or chip<br />

conveyors. They are fast, durable <strong>and</strong> offer<br />

<strong>motor</strong> protection with an added safety function.<br />

Switching, reversing<br />

<strong>and</strong> protecting <strong>motor</strong>s<br />

<strong>CONTACTRON</strong> solid-<strong>state</strong> reversing<br />

<strong>contactors</strong> ELR W are a superior alternative<br />

to mechanical <strong>contactors</strong> due to their<br />

speed, durability <strong>and</strong> cost efficiency.<br />

The devices switch <strong>and</strong> reverse <strong>motor</strong>s up<br />

to 18.5 kW. The space-saving solid-<strong>state</strong><br />

“4 in 1” reversing contactor for <strong>motor</strong>s up<br />

to 4 kW provides added <strong>motor</strong> protection<br />

<strong>and</strong> an emergency stop function.<br />

All ELR Ws can be excellently combined<br />

with the EMM <strong>motor</strong> manager, which also<br />

protects the valuable system, in addition<br />

to the <strong>motor</strong>.<br />

Fan<br />

Motors in industrial air-conditioning <strong>and</strong> ventilation<br />

systems can be switched very well using solid<strong>state</strong><br />

<strong>contactors</strong>. An additional <strong>motor</strong> manager<br />

protects the <strong>motor</strong> <strong>and</strong> system, e.g. in the event<br />

of blockages or a drive belt breakage.


Monitoring <strong>and</strong><br />

protecting systems<br />

<strong>and</strong> <strong>motor</strong>s<br />

Electric <strong>motor</strong>s often serve as a drive for<br />

valuable system parts, e.g. for actuating<br />

drives or pumps. The <strong>CONTACTRON</strong><br />

<strong>motor</strong> manager EMM uses the drive <strong>motor</strong><br />

as a sensor. It constantly monitors its<br />

effective power <strong>and</strong> all important operating<br />

data. This way, it detects overloads <strong>and</strong><br />

underloads, wear or contamination<br />

<strong>and</strong> reacts by immediately switching off the<br />

<strong>motor</strong> in the event of malfunctions. Thus, it<br />

ensures indispensable <strong>motor</strong> protection,<br />

optimizes maintenance intervals <strong>and</strong> also<br />

protects the system without complex<br />

sensor systems.<br />

Actuating drives<br />

The <strong>motor</strong> manager reliably protects actuating<br />

<strong>and</strong> regulating drives from reset failures, <strong>and</strong><br />

therefore from mechanical damage.<br />

The adjustable switching <strong>and</strong> signaling thresholds<br />

optimize the protective function.<br />

Pumps<br />

Dangerous dry running or blockage due to foreign<br />

objects: The <strong>motor</strong> manager switches the <strong>motor</strong><br />

off immediately, reliably protecting the pump<br />

<strong>and</strong> <strong>motor</strong> from the consequences of such<br />

malfunctions.<br />

Motor management –<br />

Added value for every system<br />

Motor management not only protects the <strong>motor</strong>,<br />

but also the system – without complex sensor systems.<br />

The <strong>motor</strong> manager has overload <strong>and</strong> underload<br />

detection in one device – if required, also with a<br />

fieldbus connection.<br />

Wear <strong>and</strong> contamination are detected quickly –<br />

this optimizes the maintenance intervals.<br />

Energy consumption, operating hours <strong>and</strong> many other<br />

parameters are detected „along<br />

the way“ <strong>and</strong> are immediately<br />

available.<br />

The <strong>motor</strong> manager supports<br />

the system documentation <strong>and</strong><br />

commissioning by storing data.


Automobile production<br />

System protection <strong>and</strong> avoidance of downtime<br />

have the highest priority inautomobile production<br />

<strong>and</strong> make <strong>motor</strong> management with fieldbus<br />

connections indispensable. St<strong>and</strong>ardized FDT/<br />

DTM software makes the <strong>motor</strong> manager easy to<br />

configure <strong>and</strong> use.<br />

Manage <strong>motor</strong>s with<br />

fieldbus connection<br />

In fieldbus environments, too, the<br />

<strong>CONTACTRON</strong> <strong>motor</strong> manager EMM<br />

makes intelligent <strong>motor</strong> management<br />

possible in combination with the PROFIBUS<br />

gateway EM-PB. The configuration,<br />

diagnostics <strong>and</strong> operating data acquisition<br />

of all connected <strong>motor</strong> managers are done<br />

via the user-friendly FDT/DTM software.<br />

Every gateway compactly couples up to<br />

32 <strong>motor</strong> managers to the fieldbus,<br />

providing a cost-efficient <strong>and</strong> easy-toinstall<br />

solution, especially when there is<br />

more than one monitored <strong>motor</strong>.<br />

Conveyors<br />

Fast, reliable logistics require the high availability<br />

of all system parts. The <strong>motor</strong> manager with<br />

PROFIBUS connection not only detects<br />

dangerous blockages, but also wear <strong>and</strong><br />

contamination, <strong>and</strong> therefore ensures optimum<br />

maintenance intervals.<br />

PHOENIX CONTACT 7


Functions<br />

The <strong>CONTACTRON</strong> range<br />

Motor manager – protection for <strong>motor</strong> <strong>and</strong> system<br />

new<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> – wear-free switching<br />

Left rotation Right rotation Motor<br />

protection<br />

Motor manager <strong>and</strong> PROFIBUS gateway<br />

The <strong>motor</strong> manager monitors the <strong>motor</strong> <strong>and</strong> system<br />

for overloads/underloads. A PROFIBUS gateway<br />

(available as an additional device) provides a fieldbus<br />

connection for up to 32 <strong>motor</strong> managers.<br />

An ordering overview can be found on pages 12-15<br />

“4 in 1” solid-<strong>state</strong> reversing contactor<br />

The three-phase “4 in 1” reversing contactor unifies four<br />

functions in one device for <strong>motor</strong> powers up to 4 kW.<br />

Right contactor, left contactor, <strong>motor</strong> protection relay<br />

<strong>and</strong> emergency stop up to category 3.<br />

An ordering overview can be found on pages 18-19<br />

Three-phase solid-<strong>state</strong> reversing <strong>contactors</strong><br />

The three-phase solid-<strong>state</strong> reversing <strong>contactors</strong> are<br />

suitable for the fully electronic, wear-free switching of<br />

<strong>motor</strong>s with powers up to 18.5 kW. They also have a<br />

reversing function to change the direction of rotation.<br />

An ordering overview can be found on pages 22-25<br />

1- <strong>and</strong> 3-phase solid-<strong>state</strong> <strong>contactors</strong><br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> are used in 1- <strong>and</strong> 3-phase<br />

alternating current networks which involve the quick,<br />

wear-free switching of Ohmic <strong>and</strong> inductive loads<br />

up to 18.5 kW.<br />

An ordering overview can be found on pages 26-27<br />

Emergency stop<br />

contactor<br />

Monitoring Bus<br />

connection<br />

PHOENIX CONTACT 3


The <strong>CONTACTRON</strong> <strong>motor</strong> manager –<br />

System protection needs power<br />

measurement<br />

The most important electric parameter for<br />

your system is the effective <strong>motor</strong> power.<br />

The <strong>CONTACTRON</strong> <strong>motor</strong> manager<br />

constantly monitors it <strong>and</strong> immediately<br />

detecs overload <strong>and</strong> underload <strong>state</strong>s of<br />

the <strong>motor</strong> <strong>and</strong> the system mechanics.<br />

It gives you an early warning of failures,<br />

reports maintenance requirement <strong>and</strong> thus<br />

protecting your system.<br />

How does the the <strong>CONTACTRON</strong><br />

<strong>motor</strong> manager protect your system?<br />

A cos guard monitors only the underload<br />

statuses. A <strong>motor</strong> protection relay monitors<br />

only overload statuses. With the <strong>motor</strong><br />

manager you detect all critical load statuses<br />

by measuring the effective <strong>motor</strong> power.<br />

If necessary it turns off the drive <strong>and</strong> thus<br />

protects the <strong>motor</strong> <strong>and</strong> your valuable system.<br />

cos<br />

8 PHOENIX CONTACT<br />

P mot<br />

I<br />

load<br />

Monitoring<br />

Use the <strong>motor</strong> as a sensor for<br />

the monitoring of wear <strong>and</strong><br />

malfunctions. The <strong>motor</strong> manager<br />

software thereby serves as your<br />

convenient tool for configuration,<br />

diagnose <strong>and</strong> operating data<br />

acquisition.<br />

Motor protection<br />

Thermistor evaluation, electronic<br />

<strong>motor</strong> protection relay, adjustable<br />

triggering curves:The <strong>motor</strong><br />

manager offers you full <strong>motor</strong><br />

protection in one device.


PROFIBUS Interface<br />

Save space <strong>and</strong> costs with the additionally available<br />

PROFIBUS-gateway. It connects up to 32 <strong>motor</strong><br />

managers to the fieldbus by T-Connector.<br />

The advantages:<br />

Integrated full <strong>motor</strong> protection<br />

Protection of valuable system parts<br />

Complex sensor systems not required<br />

Simple configuration <strong>and</strong> diagnostics<br />

High system availability<br />

PHOENIX CONTACT 9


The <strong>CONTACTRON</strong> <strong>motor</strong> manager –<br />

Uses the <strong>motor</strong> as a sensor <strong>and</strong> protects<br />

the system<br />

Electric <strong>motor</strong>s often serve as a drive for<br />

valuable system parts, e.g. for pumps or<br />

actuating drives. In addition to the classical<br />

<strong>motor</strong> protection, there is therefore usually<br />

a considerable amount of effort put into<br />

protecting the system, e.g. with sensors for<br />

the flow rate, torque, etc.<br />

The <strong>CONTACTRON</strong> <strong>motor</strong> manager is<br />

the efficient alternative to the complex,<br />

separate <strong>motor</strong> <strong>and</strong> system protection.<br />

It uses the drive <strong>motor</strong> as a sensor by<br />

constantly monitoring the effective power,<br />

thereby providing <strong>motor</strong> protection, system<br />

protection <strong>and</strong> operating data acquisition<br />

in one device.<br />

10 PHOENIX CONTACT<br />

Pumps<br />

Pumps can be reliably protected from dangerous dry running<br />

(<strong>motor</strong> underload) or blockages due to foreign objects<br />

(<strong>motor</strong> overload) by monitoring the effective power of the<br />

driven <strong>motor</strong>. The undesirable switch-off of the drive due to<br />

temporary malfunctions (e.g. air bubbles) can be prevented,<br />

however, via adjustable delay times. It is also possible to hide<br />

the <strong>motor</strong> start-up phase with the high inrush current from<br />

the monitor. Fans can also be monitored, e.g. for drive belt<br />

breakage, in the same manner.<br />

Effective power (P)<br />

Temporary<br />

dry run<br />

Inrush<br />

suppression<br />

Continuous dry run<br />

with forced switch-off<br />

Top performance<br />

threshold<br />

Signaling threshold for<br />

filter contamination<br />

Performance<br />

Bottom performance<br />

threshold<br />

Performance<br />

Time (t)<br />

Delay time<br />

Bottom performance<br />

threshold<br />

Time (t)


The characteristic curves of the<br />

classical <strong>motor</strong> protection <strong>and</strong> of<br />

a cos-phi monitor are not linear,<br />

especially in the important overload/<br />

underload areas, <strong>and</strong> are hard to use<br />

for system protection due to the<br />

frequent practical overdimensioning<br />

of <strong>motor</strong>s.<br />

cos phi<br />

Intelligent <strong>motor</strong> management with effective power measurement<br />

Typical<br />

load range<br />

cos phi measurement<br />

(underload detection)<br />

Actuating drives<br />

The danger of reset failures, which exists for actuating<br />

<strong>and</strong> regulating drives, can be reliably avoided by the quick<br />

detection of overloads by the <strong>motor</strong> manager. When the<br />

overload threshold is exceeded, it ensures an emergency<br />

shutdown of the drive, <strong>and</strong> can also trigger a reversing pulse,<br />

depending on the settings, which reduces the kinetic energy<br />

of the <strong>motor</strong> (coasting). This protects the <strong>motor</strong> <strong>and</strong><br />

control valves from serious consequential damage.<br />

Effective power (P)<br />

I<br />

Typical<br />

load range<br />

load load<br />

Current measurement<br />

(overload detection)<br />

Inrush suppression<br />

Drive<br />

start-up Performance<br />

Switching threshold,<br />

reset failure<br />

The <strong>motor</strong> manager, on the other<br />

h<strong>and</strong>, uses the <strong>motor</strong> as a sensor. The<br />

constantly measured effective power<br />

allows inferences to be made about its<br />

torque <strong>and</strong> therefore the mechanical<br />

loading of the drive. This way, overloads<br />

<strong>and</strong> underloads are quickly detected <strong>and</strong><br />

the <strong>motor</strong> <strong>and</strong> system can be protected<br />

by switching them off in time. Wear <strong>and</strong><br />

contamination also change the effective<br />

power, however. These processes can be<br />

monitored by means of freely definable<br />

switching <strong>and</strong> signaling thresholds <strong>and</strong><br />

maintenance requirements can be<br />

signalized in time.<br />

In addition to maintenance optimization,<br />

the <strong>motor</strong> manager also allows for<br />

extensive operating data acquisition,<br />

Switch-off by<br />

torque switch<br />

Spring element<br />

compression Reset operation<br />

Time<br />

(t)<br />

such as energy consumption,<br />

operating hours <strong>and</strong> operating cycle<br />

counting <strong>and</strong> saving complete “curves”<br />

for system documentation.<br />

P mot<br />

Machine tools<br />

The <strong>motor</strong> manager can also protect the <strong>motor</strong> <strong>and</strong><br />

expensive system parts of machine tools. By means of<br />

correspondingly parameterized power thresholds, a feed<br />

which has been set too high, for example, can be detected<br />

<strong>and</strong> the drive switched off before the tool breaks.<br />

Signaling thresholds ensure a timely warning when tool wear<br />

increases. The <strong>motor</strong> manager equally protects auxiliary<br />

drives (e.g. chip conveyors or coolant pumps) <strong>and</strong> their<br />

<strong>motor</strong>s.<br />

Effective power (P)<br />

cos<br />

Motor startup<br />

Tool positioning<br />

Inrush suppression Delay time<br />

Excess performance<br />

due to possible tool<br />

breakage<br />

Increase in performance<br />

due to tool wear<br />

Milling process<br />

I<br />

Drive switch-off<br />

load<br />

Performance threshold<br />

due to tool breakage<br />

Signaling threshold,<br />

tool wear<br />

No-load power<br />

Time<br />

(t)<br />

PHOENIX CONTACT 11


INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

Electronic <strong>motor</strong> management<br />

The <strong>motor</strong> management EMM<br />

(with/without current transformers) for all<br />

performance classes monitors <strong>and</strong> protects<br />

3-phase loads such as electrical drives.<br />

Freely parameterizable message <strong>and</strong><br />

switching thresholds can be constantly<br />

monitored for overload <strong>and</strong> underload by<br />

means of active power measurement.<br />

Digital outputs enable the controlling of<br />

external switching elements. Optional link<br />

to INTERFACE system <strong>and</strong> PROFIBUS-<br />

GATEWAY-IFS via T-BUS.<br />

solid str<strong>and</strong>ed I U<br />

[mm 2 ] AWG [A] [V]<br />

Screw connection 0.14-2.5 0.14-2.5 26-12<br />

D<br />

H W<br />

U S<br />

IN1<br />

IN2<br />

IN3<br />

IN4<br />

O1<br />

O2<br />

O3<br />

O4<br />

U S O<br />

O<br />

24 VDC<br />

Digital<br />

IN<br />

Digital<br />

OUT<br />

24 VDC<br />

Logic<br />

µP<br />

T-BUS<br />

DAT<br />

ERR<br />

L<br />

R<br />

P<br />

Thermistor<br />

Description Type Order No.<br />

IFS-<br />

Port<br />

Reset<br />

1/L1<br />

3/L2<br />

5/L3<br />

2/T1<br />

4/T2<br />

6/T3<br />

Th1<br />

Th2<br />

Pcs. /<br />

Pkt.<br />

U S<br />

IN1<br />

IN2<br />

IN3<br />

IN4<br />

O1<br />

O2<br />

O3<br />

O4<br />

U S O<br />

O<br />

Digital<br />

IN<br />

Digital<br />

OUT<br />

IFS-<br />

Port<br />

Logic<br />

µP<br />

T-BUS<br />

Reset<br />

DAT<br />

ERR<br />

P<br />

Thermistor<br />

Type Order No.<br />

Electronic <strong>motor</strong> management<br />

EMM 3- 24DC/500AC-IFS 2297497 1 EMM 3- 24DC/500AC-16-IFS 2297523 1<br />

EMM 3-230AC/500AC-IFS 2297507 1 EMM 3-230AC/500AC-16-IFS 2297536 1<br />

Programming adapter with USB interface, for programming with<br />

the IFS-CONF software<br />

IFS-USB-PROG-ADAPTER 2811271 1 IFS-USB-PROG-ADAPTER 2811271 1<br />

DIN rail connector T-BUS<br />

ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2707437 50 ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2707437 50<br />

Mini COMBICON connectors<br />

- Female contact IMC 1,5/ 5-G-3,81 1862603 50 IMC 1,5/ 5-G-3,81 1862603 50<br />

- Male contact<br />

Technical data<br />

IMC 1,5/ 5-ST-3,81 1857919 50 IMC 1,5/ 5-ST-3,81 1857919<br />

Input data EMM 3- 24DC/500AC-IFS EMM 3-230AC/500AC-IFS EMM 3- 24DC/500AC-16-IFS EMM 3-230AC/500AC-16-IFS<br />

Rated control supply voltage US 24 V DC 230 V AC 24 V DC 230 V AC<br />

Rated control supply voltage range with reference to US 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />

Rated control supply current I S at U S 25 mA 10 mA 25 mA 10 mA<br />

Operating voltage / status / error indicator LED green / LED yellow right rotation (R), LED yellow left rotation<br />

(L), LED green data communication / LED red<br />

L<br />

R<br />

V1<br />

V2<br />

V3<br />

I11<br />

I21<br />

I31<br />

I12<br />

I22<br />

I32<br />

Th1<br />

Th2<br />

Pcs. /<br />

Pkt.<br />

LED green / LED yellow right rotation (R), LED yellow left rotation<br />

(L), LED green data communication / LED red<br />

Thermistor input 1 - 6 thermistors in series 1 - 6 thermistors in series<br />

Input data of digital inputs EMM 3- 24DC/500AC-IFS EMM 3-230AC/500AC-IFS EMM 3- 24DC/500AC-16-IFS EMM 3-230AC/500AC-16-IFS<br />

Number of inputs 4 (IN1 - IN4) 4 (IN1 - IN4) 4 (IN1 - IN4) 4 (IN1 - IN4)<br />

Rated actuating voltage U C 24 V DC 230 V AC 24 V DC 230 V AC<br />

Rated actuating current I C 3.3 mA 3.5 mA 3.3 mA 3.5 mA<br />

Power measurement<br />

Voltage measuring input 42 V AC ... 575 V AC 42 V AC ... 575 V AC 42 V AC ... 575 V AC 42 V AC ... 575 V AC<br />

Nominal current, voltage measuring input < 0.5 mA < 0.5 mA - -<br />

Current measuring input 5 A Secondary external converter 5 A Secondary external converter Max. 16 A Max. 16 A<br />

Output power of the converter > 1.25 VA > 1.25 VA - -<br />

Internal resistance EMM 0.02 Ω 0.02 Ω - -<br />

Output data for confirmation contacts<br />

O1 - O4 in the case of 1 signal 24 V DC (Short-circuit-proof<br />

semiconductor output) / 500 mA<br />

EMM 3-.../500AC<br />

Electronic <strong>motor</strong> management<br />

for use of external current transformers<br />

230 V AC (Relay output; Ag<br />

alloy, hard gold-plated) / 500 mA<br />

D<br />

H W<br />

EMM 3-.../500AC-16<br />

Electronic <strong>motor</strong> management,<br />

with integrated current transformers<br />

24 V DC (Short-circuit-proof<br />

semiconductor output) / 500 mA<br />

General data<br />

Rated insulation voltage 500 V 500 V<br />

Rated surge voltage 8 kV 8 kV 8 kV 8 kV<br />

Ambient temperature range -25 °C ... 70 °C -25 °C ... 70 °C<br />

St<strong>and</strong>ards/regulations EN 60947 / EN 60947-4-2 EN 60947 / EN 60947-4-2<br />

Power station requirements DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />

EMC regulations EN 61000-6-2 / EN 61000-6-3 / EN 61000-6-4 EN 61000-6-2 / EN 61000-6-3 / EN 61000-6-4<br />

Degree of protection in acc. with IEC 60529/ EN 60529 IP20 IP20<br />

Mounting position Panel mounting on horizontal DIN rail Panel mounting on horizontal DIN rail<br />

Assembly In rows with zero spacing In rows with zero spacing<br />

Dimensions W / H / D 22.5 mm / 114.5 mm / 99 mm 22.5 mm / 114.5 mm / 99 mm<br />

12 PHOENIX CONTACT<br />

230 V AC (Relay output; Ag<br />

alloy, hard gold-plated) / 500 mA


Electronic <strong>motor</strong> management<br />

Module<br />

power supply<br />

US IN1 IN2 IN3 IN4<br />

IN1 IN2 IN3 IN4<br />

EMM 3-.../500AC-16-IFS<br />

L1<br />

L2<br />

L3<br />

EMM 3-.../500AC-IFS<br />

O UO O1 O2 O3 O4 O UO O1 O2 O3 O4<br />

Th1<br />

S<br />

Power supply<br />

Digital<br />

outputs<br />

Digital<br />

inputs<br />

Digital<br />

outputs<br />

Th1<br />

Th2<br />

Thermistor<br />

input<br />

1/L1<br />

2/T1<br />

3/L2<br />

4/T2<br />

5/L3<br />

Current measurement<br />

Current measurement<br />

The electronic <strong>motor</strong> management<br />

modules offer all the advantages of modern<br />

effective power monitoring. Every 6.6 ms,<br />

the effective power of a drive system or of<br />

any other 3-phase consumer is calculated<br />

from three currents, voltages <strong>and</strong> the phase<br />

angle. Currents of up to 16 A can be directly<br />

acquired <strong>and</strong> currents >16 A are supplied<br />

via external converters. Digital outputs can<br />

be used to control separate mechanical or<br />

electronic switching elements that adopt<br />

the actual switching of the load. In this<br />

configuration, the EMM reliably protects<br />

connected loads – irrespective of their<br />

power consumption – against overload <strong>and</strong><br />

underload, <strong>and</strong> provides permanent status<br />

monitoring.<br />

Up to 8 freely parameterizable switching,<br />

message thresholds <strong>and</strong> up to four freely<br />

configurable inputs <strong>and</strong> outputs enable the<br />

protection of electrical drives <strong>and</strong> the<br />

system.<br />

6/T3<br />

U S<br />

S<br />

Reverse running<br />

1/L1 3/L2 5/L3<br />

Reverse running<br />

1/L1 3/L2 5/L3<br />

Separate switching module<br />

Separate switching module<br />

Forward running<br />

GND<br />

2/T1 4/T2 6/T3<br />

Forward running<br />

GND<br />

2/T1 4/T2 6/T3<br />

M<br />

Module<br />

power supply<br />

Power supply<br />

Digital<br />

outputs<br />

Digital<br />

inputs<br />

Digital<br />

outputs<br />

The EMM modules can record the<br />

following data:<br />

– Apparent, effective <strong>and</strong> reactive power,<br />

– Currents <strong>and</strong> voltages,<br />

– Phase angle,<br />

– Switching-cycle <strong>and</strong> operating-hours,<br />

–Power meter.<br />

Additional Functions:<br />

– Adjustable bimetal function class 5-30<br />

– Thermistor monitor<br />

– Recording measured values<br />

– Profibus connection via TBUS<br />

– Pre-configured <strong>motor</strong> exits such as<br />

reversing starters, star delta starters, etc.<br />

The EMM modules can be used to record<br />

complete "curves" that can be used for<br />

system documentation.<br />

The operating modes right <strong>and</strong> left<br />

rotation, reverse <strong>and</strong> limit switch operation<br />

(with integrated restart inhibit) switch<br />

actuating <strong>and</strong> regulating drives, pumps etc.<br />

<strong>and</strong> also check for wear.<br />

V1<br />

V2<br />

V3<br />

Voltage<br />

measurement<br />

Th2<br />

Thermistor<br />

input<br />

INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

I11<br />

I12<br />

I21<br />

I22<br />

M<br />

I31<br />

Current<br />

measurement<br />

Current<br />

measurement<br />

I32<br />

S1/k<br />

S2/l<br />

P1<br />

P2<br />

S1/k<br />

S2/l<br />

P1<br />

P2<br />

S1/k<br />

Current transformer<br />

The external converters should be<br />

selected with a secondary nominal current<br />

of 5 A. The primary current is determined<br />

by the current consumption of the<br />

consumer (refer to connection diagram).<br />

For suitable current transformers, see<br />

catalog INTERFACE.<br />

DIN rail connector T-BUS<br />

The T-BUS (Order No. 2707437 ) can be<br />

used to supply several EMMs with 24 V DC<br />

or to connect up to 32 EMMs to the<br />

PROFIBUS-gateway.<br />

Switching element<br />

Depending on the particular requirement<br />

of the application, either an electromechanical<br />

contactor or reversing<br />

contactor combination, or a solid-<strong>state</strong><br />

contactor or a solid-<strong>state</strong> reversing<br />

contactor is to be used for the actual task of<br />

switching the load. These switching<br />

elements are controlled via the digital<br />

outputs of the EMM modules.<br />

S2/l<br />

P1<br />

P2<br />

PHOENIX CONTACT 13


INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

PROFIBUS gateway for the electronic<br />

<strong>motor</strong> management modules<br />

The EM-PB-GATEWAY-IFS is a module<br />

that enables a connection of the EMM...IFS<br />

modules to the PROFIBUS-DP.<br />

The module is certified in acc. with the<br />

DPV 1 specification (EN 50170).<br />

The EM-PB-GATEWAY-IFS can<br />

communicate with up to 32 EMM...IFS<br />

modules via the T-BUS. 8 digital inputs <strong>and</strong><br />

4 outputs can be freely parameterized.<br />

Moreover, the EM-PB-GATEWAY-IFS<br />

supports Fail Safe: The switching behavior in<br />

the event of PROFIBUS errors can be<br />

influenced by the parameterization. Digital<br />

switching outputs enable direct connection<br />

of the EMM...IFS (forward running/reverse<br />

running).<br />

The GSD file (with the communication<br />

characteristics of a PROFIBUS-DP device)<br />

can be found on the Internet under<br />

www.phoenixcontact.net/download.<br />

14 PHOENIX CONTACT<br />

Connection data solid str<strong>and</strong>ed<br />

[mm 2 ] AWG<br />

0.2-2.5 0.2-2.5 24-12<br />

B-Line 3<br />

RTS 4<br />

GND PB 5<br />

5V PB 6<br />

A-Line 8<br />

US GND<br />

24V IFS-<br />

DC Port<br />

PB<br />

Reset<br />

µController<br />

EPROM<br />

IN<br />

TO<br />

USO OUT<br />

Description Type Order No.<br />

PROFIBUS Master gateway for the INTERFACE system<br />

With screw connection<br />

Programming adapter with USB interface, for programming with<br />

the IFS-CONF software<br />

EM-PB-GATEWAY-IFS 2297620 1<br />

DIN rail connector T-BUS<br />

IFS-USB-PROG-ADAPTER 2811271 1<br />

Mini COMBICON connectors<br />

ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2707437 50<br />

- Female contact IMC 1,5/ 5-G-3,81 1862603 50<br />

- Male contact<br />

Technical data<br />

Input data<br />

IMC 1,5/ 5-ST-3,81 1857919 50<br />

Operating voltage UB 24 V DC -20 % ... +25 %<br />

Nominal input current at UIN 85 mA<br />

Input circuit<br />

Digital inputs<br />

Polarity protection, surge protection<br />

Input voltage 24 V DC ±20 %<br />

Nominal input current at UIN 3 mA<br />

Input circuit<br />

Digital outputs<br />

Polarity protection, surge protection<br />

Maximum switching voltage 23 V DC (UB - Uresid. of the output)<br />

Max. switching current 500 mA<br />

Residual voltage 1 V<br />

Output protection<br />

IFS interface<br />

Parallel protection against polarity reversal, pay attention to the fuse<br />

Type of connection<br />

PROFIBUS interface<br />

T-BUS<br />

Data rate 12 MBit/s<br />

Type of connection<br />

General data<br />

D-SUB-9<br />

Test voltage data interface/power supply 1.5 kV<br />

Ambient temperature (operation) -35 °C ... 50 °C<br />

Rated operating mode 100% operating factor<br />

St<strong>and</strong>ards/regulations EN 50178<br />

Degree of protection IP20<br />

Assembly position/mounting Any / -<br />

Dimensions W / H / D 22.5 mm / 114.5 mm / 99 mm<br />

D<br />

H W<br />

Width 22.5 mm<br />

EM-PB-GATEWAY-IFS<br />

PROFIBUS gateway<br />

Status<br />

IFS<br />

IN1<br />

IN2<br />

IN3<br />

IN4<br />

IN5<br />

IN6<br />

IN7<br />

IN8<br />

O1<br />

O2<br />

O3<br />

O4<br />

TBUS<br />

Pcs. /<br />

Pkt.


PROFIBUS gateway for the electronic<br />

<strong>motor</strong> management modules<br />

EM-PB gateway<br />

+ EMM ... IFS<br />

Startup<br />

(DPM2)<br />

Device Type Manager (DTM) for<br />

<strong>motor</strong> management modules<br />

EMM...IFS<br />

– <strong>CONTACTRON</strong>-DTM-IFS, programming<br />

adapter, manual <strong>and</strong> Quick Start Guide<br />

for the EMM..IFS system as configuration<br />

package available<br />

– Also available as USB programming<br />

adapter even individually<br />

– <strong>CONTACTRON</strong>-DTM-IFS available even<br />

for free download as an individual unit<br />

under www.phoenixcontact.com<br />

Diagnostics/maintenance<br />

(DPM2)<br />

....<br />

EM-PB gateway + EMM ... IFS 1<br />

up to EMM ... IFS 31, EMM ... IFS 32<br />

Control (PLC)<br />

(DPM1)<br />

INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

MM-CONF-SET<br />

Description Type Order No.<br />

Configuration packet for the EMM...IFS, consisting of<br />

<strong>CONTACTRON</strong>-DTM-IFS, USB programming adapter, manual<br />

<strong>and</strong> Quick Start Guide<br />

Programming adapter with USB interface, for programming with<br />

the IFS-CONF software<br />

Pcs. /<br />

Pkt.<br />

MM-CONF-SET 2297992 1<br />

IFS-USB-PROG-ADAPTER 2811271 1<br />

PHOENIX CONTACT 15


The “4 in 1” reversing contactor –<br />

No wider than your thumb!<br />

A traditional reversing circuit comprises a<br />

reversing contactor combination <strong>and</strong> a <strong>motor</strong><br />

protection relay. An additional emergency<br />

stop contactor arrangement is also often<br />

necessary to meet mechanical engineering<br />

safety requirements.<br />

All of these functions have been integrated<br />

for <strong>motor</strong>s with an engine power of up<br />

to 4 kW in the new “4 in 1” 22.5 mm<br />

solid-<strong>state</strong> reversing contactor from the<br />

<strong>CONTACTRON</strong> product range. Installation<br />

is simplified considerably <strong>and</strong> a significant<br />

amount of space is saved on the DIN rail.<br />

System availability is maximized by the nearly<br />

wear-free switching ability of the <strong>contactors</strong>.<br />

22.5 mm<br />

16 PHOENIX CONTACT<br />

No wider than your<br />

thumb! Try it!<br />

1. Left rotation<br />

Easy control via a 24 V DC or a<br />

230 V AC signal. Locking circuit<br />

<strong>and</strong> load wiring included.<br />

3. Motor protection<br />

Easy protection using the<br />

electronic <strong>motor</strong> protection<br />

relay with an automatic <strong>and</strong><br />

remote reset function.


The advantages:<br />

75% less space required<br />

75% less wiring time<br />

Service life ten times longer<br />

Integrated safety function<br />

2. Right rotation<br />

Easy control via a 24 V DC or a<br />

230 V AC signal. Locking circuit<br />

<strong>and</strong> load wiring included.<br />

SIL 3<br />

IEC 61508<br />

PL e<br />

ISO 13849-1<br />

Kat.3<br />

EN 954-1<br />

4. Emergency stop<br />

Integrated safety function for<br />

use in safety applications.<br />

PHOENIX CONTACT 17


INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

Three-phase "4 in 1" solid-<strong>state</strong><br />

reversing <strong>contactors</strong><br />

The 22.5 mm wide three-phase "4 in 1"<br />

solid-<strong>state</strong> reversing <strong>contactors</strong> with<br />

current monitoring combine four functions<br />

into one: Right contactor, left contactor,<br />

<strong>motor</strong> protection relay <strong>and</strong> EMERGENCY<br />

STOP up to category 3.<br />

The devices have the following<br />

advantages:<br />

– They save wiring<br />

– Bi-metal function settable up to 9 A<br />

– Long service life<br />

Safety level as per<br />

– IEC 61508-1 :SIL3<br />

– ISO 13849:PL e<br />

– EN 954-1:Category 3<br />

Notes:<br />

Type of housing:<br />

Polyamide PA non-reinforced, color: green.<br />

solid str<strong>and</strong>ed I U<br />

[mm 2 ] AWG [A] [V]<br />

Screw connection 0.14-2.5 0.14-2.5 26-12<br />

D<br />

H W<br />

MAN<br />

RES<br />

AUTO<br />

Us Us GND<br />

GNDE<br />

R<br />

L<br />

ELR W 3-.../500AC-2I<br />

"4 in 1" <strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />

for reversing 3~ AC <strong>motor</strong>s up to 550 V AC/3 x 2 A<br />

RES<br />

U j x v<br />

Ex: X p // Applied for: UL-EX LIS / CUL-EX LIS / GL / NV<br />

Logik<br />

µP<br />

& Error<br />

97 96 95<br />

Description Type Order No.<br />

1/L1<br />

3/L2<br />

5/L3<br />

2/T1<br />

4/T2<br />

6/T3<br />

Pcs. /<br />

Pkt.<br />

D<br />

H W<br />

MAN<br />

RES<br />

AUTO<br />

Us Us GND<br />

GNDE<br />

R<br />

L<br />

ELR W 3-.../500AC-9I<br />

"4 in 1" <strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />

for reversing 3~ AC <strong>motor</strong>s up to 550 V AC/3 x 9 A<br />

RES<br />

Logik<br />

µP<br />

& Error<br />

97 96 95<br />

Type Order No.<br />

"4 in 1" <strong>Solid</strong>-<strong>state</strong> reversing contactor<br />

ELR W3- 24DC/500AC- 2I 2297031 1 ELR W3- 24DC/500AC- 9I 2297057 1<br />

ELR W3-230AC/500AC- 2I 2297044 1 ELR W3-230AC/500AC- 9I 2297060 1<br />

Technical data<br />

Input data ELR W3- 24DC/500AC- 2I ELR W3-230AC/500AC- 2I ELR W3- 24DC/500AC- 9I ELR W3-230AC/500AC- 9I<br />

Rated control supply voltage US 24 V DC 230 V AC 24 V DC 230 V AC<br />

Rated control supply voltage range with reference to US 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />

Rated control supply current I S at U S 35 mA 3.5 mA 35 mA 3.5 mA<br />

Rated actuation voltage U C R/L 24 V DC 230 V AC 24 V DC 230 V AC<br />

Rated actuating voltage range with reference to U C 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />

U j x v<br />

Ex: X p // Applied for: UL-EX LIS / CUL-EX LIS / GL / NV<br />

Rated actuating current IC at UC 3 mA 7 mA 3 mA 7 mA<br />

Input circuit Polarity protection ,<br />

Surge protection Polarity protection ,<br />

Surge protection<br />

Surge protection<br />

Surge protection<br />

Operating voltage / status / error indicator<br />

Output data load side<br />

LED green / Yellow LED / LED red LED green / Yellow LED / LED red<br />

Output voltage range 48 V AC ... 550 V AC 48 V AC ... 550 V AC 48 V AC ... 550 V AC 48 V AC ... 550 V AC<br />

Load current Max. 2.4 A (see derating curve) Max. 2.4 A (see derating curve) Max. 9 A (see derating curve) Max. 9 A (see derating curve)<br />

Surge current 100 A (t = 10 ms) 100 A (t = 10 ms) 100 A (t = 10 ms) 100 A (t = 10 ms)<br />

Min. load current 180 mA 180 mA 1.2 A 1.2 A<br />

Residual voltage < 0.3 V < 0.3 V < 0.5 V < 0.5 V<br />

Leakage current 0 mA 0 mA 0 mA 0 mA<br />

Output protection<br />

General data<br />

Surge protection Surge protection<br />

Rated insulation voltage 500 V 500 V<br />

Rated surge voltage 6 kV 4 kV 6 kV 4 kV<br />

Reversing frequency Max. 2 Hz Max. 2 Hz Max. 2 Hz Max. 2 Hz<br />

Ambient temperature range -25 °C ... 70 °C -25 °C ... 70 °C<br />

Electrical service life 3 x 107 cycles 3 x 107 cycles<br />

St<strong>and</strong>ards/regulations DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947<br />

Power station requirements DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />

Degree of protection in acc. with IEC 60529/ EN 60529 IP20 IP20<br />

Mounting position optional (Observe derating) optional (Observe derating)<br />

Assembly Can be aligned with spacing = 20 mm Can be aligned with spacing = 20 mm<br />

Dimensions W / H / D 22.5 mm / 114.5 mm / 99 mm 22.5 mm / 114.5 mm / 99 mm<br />

Safety data<br />

EU type-examination certificate in acc. with ATEX X II (2) GD<br />

X II (2) GD<br />

X II (2) GD<br />

X II (2) GD<br />

PTB 07 ATEX 3145<br />

PTB 07 ATEX 3145<br />

PTB 07 ATEX 3145<br />

PTB 07 ATEX 3145<br />

Category in acc. with EN 954-1 3 3 3 3<br />

18 PHOENIX CONTACT<br />

1/L1<br />

3/L2<br />

5/L3<br />

2/T1<br />

4/T2<br />

6/T3<br />

Pcs. /<br />

Pkt.


Conventional structure<br />

Control current path for reversing contactor as per category 3<br />

+24V DC F5<br />

GND<br />

F 4<br />

T 1<br />

T 2<br />

K 3<br />

K 4<br />

K 4<br />

K 3<br />

K 5<br />

S 2<br />

K1 + K2 = EMERGENCY STOP contactor<br />

K3 = Left contactor<br />

K4 = Right contactor<br />

K5 = PSR SCP-24DC.../safety relay<br />

T1 = Left, T2 = Right, T3 = Reset<br />

S2 = EMERGENCY STOP<br />

F4 = Motor protection relay<br />

T 3<br />

K 5<br />

K 5<br />

K 1<br />

K 2<br />

K 5<br />

K 5<br />

K 5<br />

K 5<br />

K 5<br />

K 1<br />

K 5<br />

K 2<br />

Output current [O]<br />

Conventional structure<br />

Main current path for reversing contactor as per category 3<br />

L1<br />

L2<br />

L3<br />

F1<br />

F2<br />

F3<br />

K 1<br />

K 2<br />

K 3<br />

F 4<br />

M<br />

3~<br />

M1 K 4<br />

PE<br />

K1 + K2 = EMERGENCY STOP contactor<br />

K3 = Left contactor<br />

K4 = Right contactor<br />

F4 = Motor protection relay<br />

4<br />

3,5<br />

3<br />

2,5<br />

2<br />

1,5<br />

1<br />

0,5<br />

0,18<br />

0<br />

10 20 30 40 50 60 70<br />

Ambient temperature [°C]<br />

Derating curve ELR W 3-24DC/500AC-2I<br />

Operating time 100%<br />

Output current [O]<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0,18<br />

0<br />

2<br />

2<br />

1<br />

10 20 30 40 50 60 70<br />

Ambient temperature [°C]<br />

Derating curve ELR W 3-24DC/500AC-9I<br />

Operating time 100%<br />

1 aligned with > 20 mm spacing<br />

2 aligned without spacing<br />

1<br />

Structure with <strong>CONTACTRON</strong><br />

Main <strong>and</strong> control current path for "4 in 1" reversing contactor as<br />

per category 3<br />

F1<br />

L1<br />

F2<br />

L2<br />

F3<br />

L3<br />

+24V DC<br />

GND<br />

4<br />

3,5<br />

3<br />

2,5<br />

2<br />

1,5<br />

1<br />

0,5<br />

0,18<br />

0<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0,18<br />

0<br />

L1 L2 L3<br />

K1 T1 T2 T3<br />

T1 T2<br />

M<br />

3~<br />

M1 K1 +US R L<br />

K5 E<br />

PE<br />

K 5<br />

K1 = "4 in 1" solid-<strong>state</strong> reversing contactor<br />

K5 = PSR SCP-24DC.../safety relay<br />

T1 = Left, T2 = Right, T3 = Reset<br />

S2 = EMERGENCY STOP<br />

Output current [O]<br />

Output current [O]<br />

INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

2<br />

S 2<br />

T 3<br />

K 5<br />

K 5<br />

1<br />

K 5<br />

K 5<br />

10 20 30 40 50 60 70<br />

Ambient temperature [°C]<br />

Derating curve ELR W 3-230AC/500AC-2I<br />

Operating time 100%<br />

2<br />

1<br />

10 20 30 40 50 60 70<br />

Ambient temperature [°C]<br />

Derating curve ELR W 3-230AC/500AC-9I<br />

Operating time 100%<br />

K 5<br />

K 5<br />

PHOENIX CONTACT 19


<strong>CONTACTRON</strong> –<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> <strong>and</strong><br />

reversing <strong>contactors</strong><br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> are greatly superior<br />

to mechanical <strong>contactors</strong> with regard<br />

to switching speed, service life <strong>and</strong><br />

ruggedness. Even in dusty or chemically<br />

aggressive atmospheres, they work reliably<br />

with stable switching times. They switch<br />

Ohmic <strong>and</strong> inductive loads, e.g. in conveying<br />

equipment, lighting systems, temperature<br />

control systems or production machines,<br />

noiselessly <strong>and</strong> wear-free.<br />

The solid-<strong>state</strong> <strong>contactors</strong> from the<br />

<strong>CONTACTRON</strong> series are available for<br />

1- <strong>and</strong> 3-phase networks <strong>and</strong> also offer a<br />

reversing function, depending on the type.<br />

ELR 1…<br />

Fully electronic, wearfree<br />

switching of currents<br />

up to 50 A for 1-phase<br />

loads.<br />

20 PHOENIX CONTACT<br />

Left rotation<br />

Easy control via a 24 V DC or a<br />

230 V AC signal. Locking circuit<br />

<strong>and</strong> load wiring included.<br />

<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> offer real advantages:<br />

1. Fast:<br />

High switching frequencies make short cycle<br />

times, <strong>and</strong> therefore high productivity, possible.<br />

2. Durable:<br />

Wear-free <strong>and</strong> reliable switching with no contact<br />

bounce prevents system failures.<br />

3. Robust:<br />

Immunity to shocks, vibrations <strong>and</strong> aggressive<br />

ambient conditions allows them to be used in<br />

harsh environments.


ELR 3/ELR W 3...<br />

Fully electronic, wear-free<br />

switching for 3-phase loads<br />

up to 18.5 kW with reversing<br />

function, depending on the type.<br />

The advantages:<br />

Fast<br />

Durable<br />

Robust<br />

Right rotation<br />

Easy control via a 24 V DC or a<br />

230 V AC signal. Locking circuit<br />

<strong>and</strong> load wiring included.<br />

PHOENIX CONTACT 21


INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

Single-phase solid-<strong>state</strong> <strong>contactors</strong><br />

Single-phase solid-<strong>state</strong> <strong>contactors</strong> are<br />

used in AC voltage networks wherever<br />

silent switching, high switching frequencies<br />

<strong>and</strong> a practically unlimited service life are<br />

required.<br />

The sturdy power semi-conductors<br />

switch in zero voltage crossing <strong>and</strong> thus<br />

produce no additional high frequency<br />

interferences. The modules are insensitive<br />

to shock loads <strong>and</strong> vibrations – even use in<br />

aggressive, polluted environments is<br />

unproblematic.<br />

They offer the following advantages:<br />

– High switching frequency<br />

– wear-free <strong>and</strong> output-free,<br />

– Input voltage versions 24 V DC <strong>and</strong><br />

230 V AC.<br />

Common areas of application are:<br />

–Production machines,<br />

– Temperature controllers,<br />

– Conveyor equipment <strong>and</strong><br />

– Lighting systems.<br />

Output current[A]<br />

50<br />

40<br />

30<br />

20<br />

10 11<br />

28,5<br />

16<br />

10<br />

20<br />

Ambient temperature [°C]<br />

Load current as a function of the ambient temperature<br />

Operating time: 100% operating factor<br />

40<br />

22 PHOENIX CONTACT<br />

60<br />

Notes:<br />

Type of housing:<br />

Polycarbonate PC, color: green.<br />

For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />

H W<br />

ELR 1-.../600AC-20<br />

Single-phase solid-<strong>state</strong> contactor<br />

Description Type Order No.<br />

Single-phase solid-<strong>state</strong> contactor<br />

ELR 1- 24DC/600AC-20 2297138 1<br />

ELR 1-230AC/600AC-20 2297141 1<br />

Technical data<br />

Input data ELR 1- 24DC/600AC-20 ELR 1-230AC/600AC-20<br />

Input voltage range 4 V DC ... 32 V DC 24 V AC ... 275 V AC<br />

Typ. input current at UN Approx. 12 mA Approx. 17 mA<br />

Switching level 1 signal ("H") ≥ 4 V DC ≥ 22 V AC<br />

0 signal ("L") ≤ 1 V DC ≤ 6 V AC<br />

Transmission frequency flimit 25 Hz 6 Hz<br />

Operating voltage / status / error indicator<br />

Output data load side<br />

LED green / - / -<br />

Output voltage range 42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz)<br />

Periodic peak reverse voltage 1200 V 1200 V<br />

Load current 20 A (see derating curve) 20 A (see derating curve)<br />

Surge current 250 A (t = 10 ms) 250 A (t = 10 ms)<br />

Min. load current 350 mA 350 mA<br />

Residual voltage < 1.6 V < 1.6 V<br />

Leakage current < 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>)<br />

Phase angle (cos ϕ) 0.5 0.5<br />

Max. load value I 2 x t (t = 10 ms) 525 A 2 s 525 A 2 s<br />

Output protection RCV circuit<br />

General data<br />

Test voltage input/output 4 kV rms<br />

Ambient temperature range -30 °C ... 70 °C<br />

St<strong>and</strong>ards/regulations EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN<br />

61000-4-6 / EN 55011<br />

Mounting position Vertical (horizontal DIN rail)<br />

Assembly Can be aligned with ≥ 22.5 mm spacing<br />

Dimensions W / H / D 22.5 mm / 103 mm / 103 mm<br />

A1<br />

+<br />

A2<br />

-<br />

D<br />

Zero voltage<br />

switch<br />

u<br />

1/L1<br />

2/T1<br />

Pcs. /<br />

Pkt.


A1<br />

+<br />

A2<br />

-<br />

D<br />

H W<br />

ELR 1-.../600AC-30<br />

Single-phase solid-<strong>state</strong> contactor<br />

Zero voltage<br />

switch<br />

Type Order No.<br />

1/L1<br />

2/T1<br />

Pcs. /<br />

Pkt.<br />

D<br />

H W<br />

A1<br />

+<br />

A2<br />

-<br />

ELR 1-.../600AC-50<br />

Single-phase solid-<strong>state</strong> contactor<br />

u u<br />

Type Order No.<br />

ELR 1- 24DC/600AC-30 2297154 1 ELR 1- 24DC/600AC-50 2297170 1<br />

ELR 1-230AC/600AC-30 2297167 1 ELR 1-230AC/600AC-50 2297183 1<br />

ELR 1- 24DC/600AC-30 ELR 1-230AC/600AC-30 ELR 1- 24DC/600AC-50 ELR 1-230AC/600AC-50<br />

4 V DC ... 32 V DC 24 V AC ... 275 V AC 4 V DC ... 32 V DC 24 V AC ... 275 V AC<br />

Approx. 12 mA Approx. 17 mA Approx. 12 mA Approx. 17 mA<br />

≥ 4 V DC ≥ 22 V AC ≥ 4 V DC ≥ 22 V AC<br />

≤ 1 V DC ≤ 6 V AC ≤ 1 V DC ≤ 6 V AC<br />

25 Hz 6 Hz 25 Hz 6 Hz<br />

LED green / - / - LED green / - / -<br />

42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz)<br />

1200 V 1200 V 1200 V 1200 V<br />

30 A (see derating curve) 30 A (see derating curve) 50 A (see derating curve) 50 A (see derating curve)<br />

400 A (t = 10 ms) 400 A (t = 10 ms) 1900 A (t = 10 ms) 1900 A (t = 10 ms)<br />

150 mA 150 mA 150 mA 150 mA<br />

< 1.6 V < 1.6 V < 1.6 V < 1.6 V<br />

< 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>)<br />

0.5 0.5 0.5 0.5<br />

1800 A 2 s 1800 A 2 s 18000 A 2 s 18000 A 2 s<br />

RCV circuit RCV circuit<br />

4 kVrms 4 kVrms -30 °C ... 70 °C -30 °C ... 70 °C<br />

EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN<br />

61000-4-6 / EN 55011<br />

61000-4-6 / EN 55011<br />

Vertical (horizontal DIN rail) Vertical (horizontal DIN rail)<br />

Can be aligned with ≥ 22.5 mm spacing Can be aligned with ≥ 22.5 mm spacing<br />

22.5 mm / 103 mm / 103 mm 45 mm / 103 mm / 103 mm<br />

Zero voltage<br />

switch<br />

1/L1<br />

2/T1<br />

Pcs. /<br />

Pkt.<br />

INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

PHOENIX CONTACT 23


INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

Three-phase solid-<strong>state</strong> contactor<br />

Motors of mixers, machine tools,<br />

conveying systems, pumps <strong>and</strong> fans up to<br />

575 V AC/3x37 A (equivalent to 1 kW to<br />

18.5 kW) can be controlled using the<br />

<strong>CONTACTRON</strong> three-phase solid-<strong>state</strong><br />

<strong>contactors</strong>.<br />

Advantages of three-phase solid-<strong>state</strong><br />

<strong>contactors</strong>:<br />

– Noise-free <strong>and</strong> wear-free switching<br />

– Integrated protective circuit<br />

– Stable <strong>and</strong> short switching times<br />

– Long service life<br />

– High switching frequency<br />

– Thermal fuse optional (on request)<br />

Output current[A]<br />

Output current[A]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

10<br />

10<br />

ELR ...-9<br />

ELR ...-2<br />

20<br />

ELR ...-37<br />

ELR ...-16<br />

20<br />

40<br />

40<br />

60<br />

Ambient temperature [°C]<br />

Load current as a function of the ambient temperature<br />

Operating time: 100% operating factor<br />

60<br />

Ambient temperature [°C]<br />

Load current as a function of the ambient temperature<br />

Operating time: 100% operating factor<br />

24 PHOENIX CONTACT<br />

Notes:<br />

Type of insulation housing:<br />

ELR 3...2, ELR 3...9<br />

Polyamide PA non-reinforced, color:Green<br />

ELR 3...16, ELR 3...37<br />

Polyester PBT non-reinforced, color:Green<br />

For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />

solid str<strong>and</strong>ed I U<br />

[mm 2 ] AWG [A] [V]<br />

Screw connection 0.14-2.5 0.14-2.5 26-12<br />

D<br />

H W<br />

ON<br />

T<br />

ELR 3-.../500AC-2<br />

Three-phase solid-<strong>state</strong> contactor,<br />

for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 2 A<br />

Applied for:<br />

UL / CUL / UL-EX LIS / CUL-EX LIS<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Description Type Order No.<br />

Three-phase semiconductor contactor<br />

ELR 3- 24DC/500AC- 2 2297196 1<br />

ELR 3-230AC/500AC- 2 2297206 1<br />

Technical data<br />

Input data ELR 3- 24DC/500AC- 2 ELR 3-230AC/500AC- 2<br />

Rated actuation voltage UC ON 24 V DC 230 V AC<br />

Rated actuating voltage range with reference to UC 0.8 ... 1.25 0.4 ... 1.1<br />

Rated actuating current IC at UC 8.3 mA 12.5 mA<br />

Input circuit Polarity protection ,<br />

Surge protection<br />

Surge protection<br />

Operating voltage / status / error indicator<br />

Output data load side<br />

- / Yellow LED / LED red<br />

Output voltage range 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />

Periodic peak reverse voltage 1200 V 1200 V<br />

Load current Max. 2 A (see derating curve) Max. 2 A (see derating curve)<br />

Surge current 200 A (t = 10 ms) 200 A (t = 10 ms)<br />

Min. load current 100 mA 100 mA<br />

Residual voltage < 1.5 V < 1.5 V<br />

Leakage current 6 mA 6 mA<br />

Max. load value I 2 x t (t = 10 ms) 250 A 2s 250 A 2s<br />

Output protection RCV circuit<br />

General data<br />

Rated insulation voltage 500 V<br />

Rated surge voltage 6 kV 6 kV<br />

Switching frequency Max. 10 Hz Max. 1 Hz<br />

Ambient temperature range -25 °C ... 70 °C<br />

St<strong>and</strong>ards/regulations DIN EN 50178 / EN 60947<br />

Power station requirements DWR 1300 / ZXX01/DD/7080.8d<br />

Degree of protection in acc. with IEC 60529/ EN 60529 IP20<br />

Mounting position Horizontal (observe derating)<br />

Assembly Can be aligned with spacing = 20 mm<br />

Dimensions W / H / D 40 mm / 114.5 mm / 99 mm<br />

Pcs. /<br />

Pkt.


D<br />

H W<br />

ON<br />

T<br />

ELR 3-.../500AC-9<br />

Three-phase solid-<strong>state</strong> contactor,<br />

for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3x9 A<br />

Applied for:<br />

UL / CUL / UL-EX LIS / CUL-EX LIS<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Type Order No.<br />

Pcs. /<br />

Pkt.<br />

D<br />

H W<br />

ON<br />

T<br />

ELR 3-.../500AC-16<br />

Three-phase solid-<strong>state</strong> contactor,<br />

for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 16 A<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Type Order No.<br />

Pcs. /<br />

Pkt.<br />

INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

D<br />

H W<br />

ON<br />

T<br />

ELR 2+1-.../500AC-37<br />

Three-phase solid-<strong>state</strong> contactor,<br />

for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 37 A<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Type Order No.<br />

ELR 3- 24DC/500AC- 9 2297219 1 ELR 3- 24DC/500AC-16 2297235 1 ELR 2+1- 24DC/500AC-37 2297277 1<br />

ELR 3-230AC/500AC- 9 2297222 1 ELR 3-230AC/500AC-16 2297248 1 ELR 2+1-230AC/500AC-37 2297280 1<br />

ELR 3- 24DC/500AC- 9 ELR 3-230AC/500AC- 9 ELR 3- 24DC/500AC-16 ELR 3-230AC/500AC-16 ELR 2+1- 24DC/500AC-37 ELR 2+1-230AC/500AC-37<br />

24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC<br />

0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />

8.3 mA 12.5 mA 8.3 mA 12.5 mA 8.3 mA 12.5 mA<br />

Polarity protection ,<br />

Surge protection Polarity protection ,<br />

Surge protection Polarity protection ,<br />

Surge protection<br />

Surge protection<br />

Surge protection<br />

Surge protection<br />

- / Yellow LED / LED red - / Yellow LED / LED red - / Yellow LED / LED red<br />

48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />

1200 V 1200 V 1200 V 1200 V 1200 V 1200 V<br />

Max. 9 A (see derating curve) Max. 9 A (see derating curve) Max. 16 A (see derating curve) Max. 16 A (see derating curve) Max. 37 A (see derating curve) Max. 37 A (see derating curve)<br />

300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 1300 A (t = 10 ms) 1300 A (t = 10 ms)<br />

100 mA 100 mA 100 mA 100 mA 200 mA 200 mA<br />

< 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V<br />

6 mA 6 mA 6 mA 6 mA 6 mA 6 mA<br />

580 A 2s 580 A 2s 580 A 2s 580 A 2s 9000 A 2s 9000 A 2s<br />

RCV circuit RCV circuit RCV circuit<br />

500 V 500 V 500 V<br />

6 kV 6 kV 6 kV 6 kV 6 kV 6 kV<br />

Max. 10 Hz Max. 1 Hz Max. 10 Hz Max. 1 Hz Max. 10 Hz Max. 1 Hz<br />

-25 °C ... 70 °C -25 °C ... 70 °C -25 °C ... 70 °C<br />

DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947<br />

DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />

IP20 IP20 IP20<br />

Horizontal (observe derating) Horizontal (observe derating) Horizontal (observe derating)<br />

Can be aligned with spacing = 20 mm Can be aligned with spacing = 40 mm Can be aligned with spacing = 40 mm<br />

67.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm<br />

Pcs. /<br />

Pkt.<br />

PHOENIX CONTACT 25


INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

Three-phase solid-<strong>state</strong> reversing<br />

<strong>contactors</strong><br />

The three-phase solid-<strong>state</strong> reversing<br />

<strong>contactors</strong> with an integrated locking circuit<br />

<strong>and</strong> load wiring are intended for applications<br />

such as control valves, slides, separating<br />

filters, ship steering gears, etc. The scope of<br />

performance ranges from 575 V AC/3 x 2 A<br />

to 575 V AC/3 x 37 A.<br />

Advantages of three-phase solid-<strong>state</strong><br />

reversing <strong>contactors</strong>:<br />

– Noise-free <strong>and</strong> wear-free switching<br />

– Integrated protective circuit<br />

– Stable <strong>and</strong> short switching times<br />

– Long service life<br />

– High switching frequency<br />

– Integrated locking <strong>and</strong> load wiring<br />

– Thermal fuse optional (on request)<br />

Output current[A]<br />

Output current[A]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

10<br />

10<br />

ELR ...-9<br />

ELR ...-2<br />

20<br />

ELR ...-37<br />

ELR ...-16<br />

20<br />

40<br />

40<br />

60<br />

Ambient temperature [°C]<br />

Load current as a function of the ambient temperature<br />

Operating time: 100% operating factor<br />

60<br />

Ambient temperature [°C]<br />

Load current as a function of the ambient temperature<br />

Operating time: 100% operating factor<br />

26 PHOENIX CONTACT<br />

Notes:<br />

Type of insulation housing:<br />

ELR W 3...2, ELR W 3...9<br />

Polyamide PA non-reinforced, color:Green<br />

ELR W 3...16, ELR W 3...37<br />

Polyester PBT non-reinforced, color:Green<br />

For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />

solid str<strong>and</strong>ed I U<br />

[mm 2 ] AWG [A] [V]<br />

Screw connection 0.14-2.5 0.14-2.5 26-12<br />

D<br />

H W<br />

R<br />

T<br />

L<br />

T<br />

ELR W 3-.../500AC-2<br />

<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />

for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 2 A<br />

Applied for:<br />

UL / CUL / UL-EX LIS / CUL-EX LIS<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Description Type Order No.<br />

<strong>Solid</strong>-<strong>state</strong> reversing contactor<br />

ELR W3- 24DC/500AC- 2 2297293 1<br />

ELR W3-230AC/500AC- 2 2297303 1<br />

Technical data<br />

Input data ELR W3- 24DC/500AC- 2 ELR W3-230AC/500AC- 2<br />

Rated actuation voltage UC R/L 24 V DC 230 V AC<br />

Rated actuating voltage range with reference to UC 0.8 ... 1.25 0.4 ... 1.1<br />

Rated actuating current IC at UC 12.7 mA 11.2 mA<br />

Input circuit Polarity protection ,<br />

Surge protection<br />

Surge protection<br />

Operating voltage / status / error indicator<br />

Output data load side<br />

- / Yellow LED / LED red<br />

Output voltage range 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />

Periodic peak reverse voltage 1200 V 1200 V<br />

Load current Max. 2 A (see derating curve) Max. 2 A (see derating curve)<br />

Surge current 200 A (t = 10 ms) 200 A (t = 10 ms)<br />

Min. load current 100 mA 100 mA<br />

Residual voltage < 1.5 V < 1.5 V<br />

Leakage current 6 mA 6 mA<br />

Max. load value I 2 x t (t = 10 ms) 250 A 2s 250 A 2s<br />

Output protection RCV circuit<br />

General data<br />

Rated insulation voltage 500 V<br />

Rated surge voltage 6 kV 6 kV<br />

Reversing frequency Max. 10 Hz Max. 2 Hz<br />

Switching frequency Max. 5 Hz Max. 1 Hz<br />

Ambient temperature range -25 °C ... 70 °C<br />

St<strong>and</strong>ards/regulations DIN EN 50178 / EN 60947<br />

Power station requirements DWR 1300 / ZXX01/DD/7080.8d<br />

Degree of protection in acc. with IEC 60529/ EN 60529 IP20<br />

Mounting position Horizontal (observe derating)<br />

Assembly Can be aligned with spacing = 20 mm<br />

Dimensions W / H / D 40 mm / 114.5 mm / 99 mm<br />

Pcs. /<br />

Pkt.


D<br />

H W<br />

R<br />

T<br />

L<br />

T<br />

ELR W 3-.../500AC-9<br />

<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />

for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3x9 A<br />

Applied for:<br />

UL / CUL / UL-EX LIS / CUL-EX LIS<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Type Order No.<br />

Pcs. /<br />

Pkt.<br />

D<br />

H W<br />

R<br />

T<br />

L<br />

T<br />

ELR W 3-.../500AC-16<br />

<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />

for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 16 A<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Type Order No.<br />

Pcs. /<br />

Pkt.<br />

INTERFACE Relay<br />

<strong>CONTACTRON</strong> – Power electronics<br />

D<br />

H W<br />

R<br />

T<br />

L<br />

T<br />

ELR W 2+1-.../500AC-37<br />

<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />

for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 37 A<br />

1/L1 3/L2 5/L3<br />

2/T1 4/T2 6/T3<br />

Type Order No.<br />

ELR W3- 24DC/500AC- 9 2297316 1 ELR W3- 24DC/500AC-16 2297332 1 ELR W2+1- 24DC/500AC-37 2297374 1<br />

ELR W3-230AC/500AC- 9 2297329 1 ELR W3-230AC/500AC-16 2297345 1 ELR W2+1-230AC/500AC-37 2297387 1<br />

ELR W3- 24DC/500AC- 9 ELR W3-230AC/500AC- 9 ELR W3- 24DC/500AC-16 ELR W3-230AC/500AC-16 ELR W2+1- 24DC/500AC-37 ELR W2+1-230AC/500AC-37<br />

24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC<br />

0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />

12.7 mA 11.2 mA 12.7 mA 11.2 mA 12.7 mA 11.2 mA<br />

Polarity protection ,<br />

Surge protection Polarity protection ,<br />

Surge protection Polarity protection ,<br />

Surge protection<br />

Surge protection<br />

Surge protection<br />

Surge protection<br />

- / Yellow LED / LED red - / Yellow LED / LED red - / Yellow LED / LED red<br />

48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />

1200 V 1200 V 1200 V 1200 V 1200 V 1200 V<br />

Max. 9 A (see derating curve) Max. 9 A (see derating curve) Max. 16 A (see derating curve) Max. 16 A (see derating curve) Max. 37 A (see derating curve) Max. 37 A (see derating curve)<br />

300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 1300 A (t = 10 ms) 1300 A (t = 10 ms)<br />

100 mA 100 mA 100 mA 100 mA 200 mA 200 mA<br />

< 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V<br />

6 mA 6 mA 6 mA 6 mA 6 mA 6 mA<br />

580 A 2s 580 A 2s 580 A 2s 580 A 2s 9000 A 2s 9000 A 2s<br />

RCV circuit RCV circuit RCV circuit<br />

500 V 500 V 500 V<br />

6 kV 6 kV 6 kV 6 kV 6 kV 6 kV<br />

Max. 10 Hz Max. 2 Hz Max. 10 Hz Max. 2 Hz Max. 10 Hz Max. 2 Hz<br />

Max. 5 Hz Max. 1 Hz Max. 5 Hz Max. 1 Hz Max. 5 Hz Max. 1 Hz<br />

-25 °C ... 70 °C -25 °C ... 70 °C -25 °C ... 70 °C<br />

DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947<br />

DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />

IP20 IP20 IP20<br />

Horizontal (observe derating) Horizontal (observe derating) Horizontal (observe derating)<br />

Can be aligned with spacing = 20 mm Can be aligned with spacing = 40 mm Can be aligned with spacing = 40 mm<br />

67.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm<br />

Pcs. /<br />

Pkt.<br />

PHOENIX CONTACT 27


Further information on the products<br />

introduced here <strong>and</strong> on the world of solutions<br />

from <strong>Phoenix</strong> <strong>Contact</strong> can be found at<br />

www.phoenixcontact.net/catalog<br />

Or contact us directly!<br />

PHOENIX CONTACT GmbH & Co. KG<br />

32823 Blomberg, Germany<br />

Phone: +49/52 35/3-00<br />

Fax: +49/52 35/3-1 07 99<br />

www.phoenixcontact.com<br />

Components <strong>and</strong> Systems<br />

AUTOMATION<br />

Industrial Connection Systems,<br />

Marking <strong>and</strong> Mounting Material<br />

CLIPLINE<br />

Connection Technology<br />

for Field Devices <strong>and</strong> Field Cabling<br />

PLUSCON<br />

Device Connection Technology<br />

<strong>and</strong> Electronic Housing<br />

COMBICON<br />

Surge Protection<br />

TRABTECH<br />

Signal Converters, Switching Devices<br />

<strong>and</strong> Power Supplies<br />

INTERFACE<br />

MNR 52003803/11.03.2009-02 Printed in Germany © PHOENIX CONTACT 2009