<strong>CONTACTRON</strong><br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> <strong>and</strong><br />
<strong>motor</strong> management
<strong>CONTACTRON</strong> –<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> <strong>and</strong><br />
<strong>motor</strong> management<br />
Maximum availability <strong>and</strong> optimal productivity<br />
are preconditions for the competitiveness of<br />
an industrial system. The short cycle times<br />
required for this <strong>and</strong> optimal maintenance<br />
cycles can often no longer be realized by<br />
conventional <strong>motor</strong> control systems with<br />
mechanical <strong>contactors</strong>.<br />
<strong>CONTACTRON</strong> solid-<strong>state</strong> <strong>contactors</strong> from<br />
<strong>Phoenix</strong> <strong>Contact</strong> are the durable <strong>and</strong> costsaving<br />
alternative to contactor technology.<br />
<strong>CONTACTRON</strong> power electronics are used<br />
everywhere where frequent, reliable <strong>and</strong><br />
wear-free switching is dem<strong>and</strong>ed.<br />
<strong>CONTACTRON</strong> –<br />
Added value for your system<br />
1. <strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> switch quickly <strong>and</strong><br />
wear-free – that lowers maintenance costs<br />
<strong>and</strong> increases productivity.<br />
2. The <strong>motor</strong> manager has overload <strong>and</strong><br />
underload detection in one device. That not<br />
only protects the <strong>motor</strong>, but also the system<br />
– without complex sensor systems.<br />
3. Motor managers <strong>and</strong> solid-<strong>state</strong> <strong>contactors</strong><br />
can be ideally combined to form fast, costsaving<br />
<strong>and</strong> durable <strong>motor</strong> controls – if<br />
necessary, also with a fieldbus connection.<br />
2 PHOENIX CONTACT
Fast <strong>and</strong> wear-free<br />
switching<br />
The advantages of the <strong>CONTACTRON</strong><br />
ELR 1 <strong>and</strong> ELR 3 solid-<strong>state</strong> contactor<br />
series are ruggedness, long-term<br />
stable switching times <strong>and</strong> a practically<br />
unlimited service life, otherwise not<br />
achieved by mechanical <strong>contactors</strong>.<br />
This makes it ideal for applications with<br />
high switching frequencies, such as heating<br />
controls, lighting systems <strong>and</strong> controlling of<br />
1- <strong>and</strong> 3-phase <strong>motor</strong>s up to 18.5 kW.<br />
Lighting control system<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> provide the high switching<br />
frequencies <strong>and</strong> highly precise switching times<br />
required for professional lighting systems.<br />
4 PHOENIX CONTACT<br />
Plastic injection molding systems<br />
High production quality for plastic injection<br />
molding requires a constant temperature in the<br />
heating zones <strong>and</strong> exact regulation by means<br />
of frequent switching on <strong>and</strong> off. <strong>Solid</strong>-<strong>state</strong><br />
<strong>contactors</strong> can fulfill this switching task reliably<br />
<strong>and</strong> long-term.
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> offer many<br />
advantages<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> switch wear-free –<br />
that lowers maintenance costs.<br />
Productivity increased by short <strong>and</strong> stable switching<br />
times.<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> are suitable<br />
for use in harsh environments.<br />
Long service life <strong>and</strong> built-in<br />
protective circuit prevent<br />
downtime.<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> can be<br />
directly controlled by the PLC.<br />
Machine tools<br />
The space-saving “4 in 1” solid-<strong>state</strong> reversing<br />
<strong>contactors</strong> are excellently suited for <strong>motor</strong>s<br />
in auxiliary drives, e.g. coolant pumps or chip<br />
conveyors. They are fast, durable <strong>and</strong> offer<br />
<strong>motor</strong> protection with an added safety function.<br />
Switching, reversing<br />
<strong>and</strong> protecting <strong>motor</strong>s<br />
<strong>CONTACTRON</strong> solid-<strong>state</strong> reversing<br />
<strong>contactors</strong> ELR W are a superior alternative<br />
to mechanical <strong>contactors</strong> due to their<br />
speed, durability <strong>and</strong> cost efficiency.<br />
The devices switch <strong>and</strong> reverse <strong>motor</strong>s up<br />
to 18.5 kW. The space-saving solid-<strong>state</strong><br />
“4 in 1” reversing contactor for <strong>motor</strong>s up<br />
to 4 kW provides added <strong>motor</strong> protection<br />
<strong>and</strong> an emergency stop function.<br />
All ELR Ws can be excellently combined<br />
with the EMM <strong>motor</strong> manager, which also<br />
protects the valuable system, in addition<br />
to the <strong>motor</strong>.<br />
Fan<br />
Motors in industrial air-conditioning <strong>and</strong> ventilation<br />
systems can be switched very well using solid<strong>state</strong><br />
<strong>contactors</strong>. An additional <strong>motor</strong> manager<br />
protects the <strong>motor</strong> <strong>and</strong> system, e.g. in the event<br />
of blockages or a drive belt breakage.
Monitoring <strong>and</strong><br />
protecting systems<br />
<strong>and</strong> <strong>motor</strong>s<br />
Electric <strong>motor</strong>s often serve as a drive for<br />
valuable system parts, e.g. for actuating<br />
drives or pumps. The <strong>CONTACTRON</strong><br />
<strong>motor</strong> manager EMM uses the drive <strong>motor</strong><br />
as a sensor. It constantly monitors its<br />
effective power <strong>and</strong> all important operating<br />
data. This way, it detects overloads <strong>and</strong><br />
underloads, wear or contamination<br />
<strong>and</strong> reacts by immediately switching off the<br />
<strong>motor</strong> in the event of malfunctions. Thus, it<br />
ensures indispensable <strong>motor</strong> protection,<br />
optimizes maintenance intervals <strong>and</strong> also<br />
protects the system without complex<br />
sensor systems.<br />
Actuating drives<br />
The <strong>motor</strong> manager reliably protects actuating<br />
<strong>and</strong> regulating drives from reset failures, <strong>and</strong><br />
therefore from mechanical damage.<br />
The adjustable switching <strong>and</strong> signaling thresholds<br />
optimize the protective function.<br />
Pumps<br />
Dangerous dry running or blockage due to foreign<br />
objects: The <strong>motor</strong> manager switches the <strong>motor</strong><br />
off immediately, reliably protecting the pump<br />
<strong>and</strong> <strong>motor</strong> from the consequences of such<br />
malfunctions.<br />
Motor management –<br />
Added value for every system<br />
Motor management not only protects the <strong>motor</strong>,<br />
but also the system – without complex sensor systems.<br />
The <strong>motor</strong> manager has overload <strong>and</strong> underload<br />
detection in one device – if required, also with a<br />
fieldbus connection.<br />
Wear <strong>and</strong> contamination are detected quickly –<br />
this optimizes the maintenance intervals.<br />
Energy consumption, operating hours <strong>and</strong> many other<br />
parameters are detected „along<br />
the way“ <strong>and</strong> are immediately<br />
available.<br />
The <strong>motor</strong> manager supports<br />
the system documentation <strong>and</strong><br />
commissioning by storing data.
Automobile production<br />
System protection <strong>and</strong> avoidance of downtime<br />
have the highest priority inautomobile production<br />
<strong>and</strong> make <strong>motor</strong> management with fieldbus<br />
connections indispensable. St<strong>and</strong>ardized FDT/<br />
DTM software makes the <strong>motor</strong> manager easy to<br />
configure <strong>and</strong> use.<br />
Manage <strong>motor</strong>s with<br />
fieldbus connection<br />
In fieldbus environments, too, the<br />
<strong>CONTACTRON</strong> <strong>motor</strong> manager EMM<br />
makes intelligent <strong>motor</strong> management<br />
possible in combination with the PROFIBUS<br />
gateway EM-PB. The configuration,<br />
diagnostics <strong>and</strong> operating data acquisition<br />
of all connected <strong>motor</strong> managers are done<br />
via the user-friendly FDT/DTM software.<br />
Every gateway compactly couples up to<br />
32 <strong>motor</strong> managers to the fieldbus,<br />
providing a cost-efficient <strong>and</strong> easy-toinstall<br />
solution, especially when there is<br />
more than one monitored <strong>motor</strong>.<br />
Conveyors<br />
Fast, reliable logistics require the high availability<br />
of all system parts. The <strong>motor</strong> manager with<br />
PROFIBUS connection not only detects<br />
dangerous blockages, but also wear <strong>and</strong><br />
contamination, <strong>and</strong> therefore ensures optimum<br />
maintenance intervals.<br />
PHOENIX CONTACT 7
Functions<br />
The <strong>CONTACTRON</strong> range<br />
Motor manager – protection for <strong>motor</strong> <strong>and</strong> system<br />
new<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> – wear-free switching<br />
Left rotation Right rotation Motor<br />
protection<br />
Motor manager <strong>and</strong> PROFIBUS gateway<br />
The <strong>motor</strong> manager monitors the <strong>motor</strong> <strong>and</strong> system<br />
for overloads/underloads. A PROFIBUS gateway<br />
(available as an additional device) provides a fieldbus<br />
connection for up to 32 <strong>motor</strong> managers.<br />
An ordering overview can be found on pages 12-15<br />
“4 in 1” solid-<strong>state</strong> reversing contactor<br />
The three-phase “4 in 1” reversing contactor unifies four<br />
functions in one device for <strong>motor</strong> powers up to 4 kW.<br />
Right contactor, left contactor, <strong>motor</strong> protection relay<br />
<strong>and</strong> emergency stop up to category 3.<br />
An ordering overview can be found on pages 18-19<br />
Three-phase solid-<strong>state</strong> reversing <strong>contactors</strong><br />
The three-phase solid-<strong>state</strong> reversing <strong>contactors</strong> are<br />
suitable for the fully electronic, wear-free switching of<br />
<strong>motor</strong>s with powers up to 18.5 kW. They also have a<br />
reversing function to change the direction of rotation.<br />
An ordering overview can be found on pages 22-25<br />
1- <strong>and</strong> 3-phase solid-<strong>state</strong> <strong>contactors</strong><br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> are used in 1- <strong>and</strong> 3-phase<br />
alternating current networks which involve the quick,<br />
wear-free switching of Ohmic <strong>and</strong> inductive loads<br />
up to 18.5 kW.<br />
An ordering overview can be found on pages 26-27<br />
Emergency stop<br />
contactor<br />
Monitoring Bus<br />
connection<br />
PHOENIX CONTACT 3
The <strong>CONTACTRON</strong> <strong>motor</strong> manager –<br />
System protection needs power<br />
measurement<br />
The most important electric parameter for<br />
your system is the effective <strong>motor</strong> power.<br />
The <strong>CONTACTRON</strong> <strong>motor</strong> manager<br />
constantly monitors it <strong>and</strong> immediately<br />
detecs overload <strong>and</strong> underload <strong>state</strong>s of<br />
the <strong>motor</strong> <strong>and</strong> the system mechanics.<br />
It gives you an early warning of failures,<br />
reports maintenance requirement <strong>and</strong> thus<br />
protecting your system.<br />
How does the the <strong>CONTACTRON</strong><br />
<strong>motor</strong> manager protect your system?<br />
A cos guard monitors only the underload<br />
statuses. A <strong>motor</strong> protection relay monitors<br />
only overload statuses. With the <strong>motor</strong><br />
manager you detect all critical load statuses<br />
by measuring the effective <strong>motor</strong> power.<br />
If necessary it turns off the drive <strong>and</strong> thus<br />
protects the <strong>motor</strong> <strong>and</strong> your valuable system.<br />
cos<br />
8 PHOENIX CONTACT<br />
P mot<br />
I<br />
load<br />
Monitoring<br />
Use the <strong>motor</strong> as a sensor for<br />
the monitoring of wear <strong>and</strong><br />
malfunctions. The <strong>motor</strong> manager<br />
software thereby serves as your<br />
convenient tool for configuration,<br />
diagnose <strong>and</strong> operating data<br />
acquisition.<br />
Motor protection<br />
Thermistor evaluation, electronic<br />
<strong>motor</strong> protection relay, adjustable<br />
triggering curves:The <strong>motor</strong><br />
manager offers you full <strong>motor</strong><br />
protection in one device.
PROFIBUS Interface<br />
Save space <strong>and</strong> costs with the additionally available<br />
PROFIBUS-gateway. It connects up to 32 <strong>motor</strong><br />
managers to the fieldbus by T-Connector.<br />
The advantages:<br />
Integrated full <strong>motor</strong> protection<br />
Protection of valuable system parts<br />
Complex sensor systems not required<br />
Simple configuration <strong>and</strong> diagnostics<br />
High system availability<br />
PHOENIX CONTACT 9
The <strong>CONTACTRON</strong> <strong>motor</strong> manager –<br />
Uses the <strong>motor</strong> as a sensor <strong>and</strong> protects<br />
the system<br />
Electric <strong>motor</strong>s often serve as a drive for<br />
valuable system parts, e.g. for pumps or<br />
actuating drives. In addition to the classical<br />
<strong>motor</strong> protection, there is therefore usually<br />
a considerable amount of effort put into<br />
protecting the system, e.g. with sensors for<br />
the flow rate, torque, etc.<br />
The <strong>CONTACTRON</strong> <strong>motor</strong> manager is<br />
the efficient alternative to the complex,<br />
separate <strong>motor</strong> <strong>and</strong> system protection.<br />
It uses the drive <strong>motor</strong> as a sensor by<br />
constantly monitoring the effective power,<br />
thereby providing <strong>motor</strong> protection, system<br />
protection <strong>and</strong> operating data acquisition<br />
in one device.<br />
10 PHOENIX CONTACT<br />
Pumps<br />
Pumps can be reliably protected from dangerous dry running<br />
(<strong>motor</strong> underload) or blockages due to foreign objects<br />
(<strong>motor</strong> overload) by monitoring the effective power of the<br />
driven <strong>motor</strong>. The undesirable switch-off of the drive due to<br />
temporary malfunctions (e.g. air bubbles) can be prevented,<br />
however, via adjustable delay times. It is also possible to hide<br />
the <strong>motor</strong> start-up phase with the high inrush current from<br />
the monitor. Fans can also be monitored, e.g. for drive belt<br />
breakage, in the same manner.<br />
Effective power (P)<br />
Temporary<br />
dry run<br />
Inrush<br />
suppression<br />
Continuous dry run<br />
with forced switch-off<br />
Top performance<br />
threshold<br />
Signaling threshold for<br />
filter contamination<br />
Performance<br />
Bottom performance<br />
threshold<br />
Performance<br />
Time (t)<br />
Delay time<br />
Bottom performance<br />
threshold<br />
Time (t)
The characteristic curves of the<br />
classical <strong>motor</strong> protection <strong>and</strong> of<br />
a cos-phi monitor are not linear,<br />
especially in the important overload/<br />
underload areas, <strong>and</strong> are hard to use<br />
for system protection due to the<br />
frequent practical overdimensioning<br />
of <strong>motor</strong>s.<br />
cos phi<br />
Intelligent <strong>motor</strong> management with effective power measurement<br />
Typical<br />
load range<br />
cos phi measurement<br />
(underload detection)<br />
Actuating drives<br />
The danger of reset failures, which exists for actuating<br />
<strong>and</strong> regulating drives, can be reliably avoided by the quick<br />
detection of overloads by the <strong>motor</strong> manager. When the<br />
overload threshold is exceeded, it ensures an emergency<br />
shutdown of the drive, <strong>and</strong> can also trigger a reversing pulse,<br />
depending on the settings, which reduces the kinetic energy<br />
of the <strong>motor</strong> (coasting). This protects the <strong>motor</strong> <strong>and</strong><br />
control valves from serious consequential damage.<br />
Effective power (P)<br />
I<br />
Typical<br />
load range<br />
load load<br />
Current measurement<br />
(overload detection)<br />
Inrush suppression<br />
Drive<br />
start-up Performance<br />
Switching threshold,<br />
reset failure<br />
The <strong>motor</strong> manager, on the other<br />
h<strong>and</strong>, uses the <strong>motor</strong> as a sensor. The<br />
constantly measured effective power<br />
allows inferences to be made about its<br />
torque <strong>and</strong> therefore the mechanical<br />
loading of the drive. This way, overloads<br />
<strong>and</strong> underloads are quickly detected <strong>and</strong><br />
the <strong>motor</strong> <strong>and</strong> system can be protected<br />
by switching them off in time. Wear <strong>and</strong><br />
contamination also change the effective<br />
power, however. These processes can be<br />
monitored by means of freely definable<br />
switching <strong>and</strong> signaling thresholds <strong>and</strong><br />
maintenance requirements can be<br />
signalized in time.<br />
In addition to maintenance optimization,<br />
the <strong>motor</strong> manager also allows for<br />
extensive operating data acquisition,<br />
Switch-off by<br />
torque switch<br />
Spring element<br />
compression Reset operation<br />
Time<br />
(t)<br />
such as energy consumption,<br />
operating hours <strong>and</strong> operating cycle<br />
counting <strong>and</strong> saving complete “curves”<br />
for system documentation.<br />
P mot<br />
Machine tools<br />
The <strong>motor</strong> manager can also protect the <strong>motor</strong> <strong>and</strong><br />
expensive system parts of machine tools. By means of<br />
correspondingly parameterized power thresholds, a feed<br />
which has been set too high, for example, can be detected<br />
<strong>and</strong> the drive switched off before the tool breaks.<br />
Signaling thresholds ensure a timely warning when tool wear<br />
increases. The <strong>motor</strong> manager equally protects auxiliary<br />
drives (e.g. chip conveyors or coolant pumps) <strong>and</strong> their<br />
<strong>motor</strong>s.<br />
Effective power (P)<br />
cos<br />
Motor startup<br />
Tool positioning<br />
Inrush suppression Delay time<br />
Excess performance<br />
due to possible tool<br />
breakage<br />
Increase in performance<br />
due to tool wear<br />
Milling process<br />
I<br />
Drive switch-off<br />
load<br />
Performance threshold<br />
due to tool breakage<br />
Signaling threshold,<br />
tool wear<br />
No-load power<br />
Time<br />
(t)<br />
PHOENIX CONTACT 11
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
Electronic <strong>motor</strong> management<br />
The <strong>motor</strong> management EMM<br />
(with/without current transformers) for all<br />
performance classes monitors <strong>and</strong> protects<br />
3-phase loads such as electrical drives.<br />
Freely parameterizable message <strong>and</strong><br />
switching thresholds can be constantly<br />
monitored for overload <strong>and</strong> underload by<br />
means of active power measurement.<br />
Digital outputs enable the controlling of<br />
external switching elements. Optional link<br />
to INTERFACE system <strong>and</strong> PROFIBUS-<br />
GATEWAY-IFS via T-BUS.<br />
solid str<strong>and</strong>ed I U<br />
[mm 2 ] AWG [A] [V]<br />
Screw connection 0.14-2.5 0.14-2.5 26-12<br />
D<br />
H W<br />
U S<br />
IN1<br />
IN2<br />
IN3<br />
IN4<br />
O1<br />
O2<br />
O3<br />
O4<br />
U S O<br />
O<br />
24 VDC<br />
Digital<br />
IN<br />
Digital<br />
OUT<br />
24 VDC<br />
Logic<br />
µP<br />
T-BUS<br />
DAT<br />
ERR<br />
L<br />
R<br />
P<br />
Thermistor<br />
Description Type Order No.<br />
IFS-<br />
Port<br />
Reset<br />
1/L1<br />
3/L2<br />
5/L3<br />
2/T1<br />
4/T2<br />
6/T3<br />
Th1<br />
Th2<br />
Pcs. /<br />
Pkt.<br />
U S<br />
IN1<br />
IN2<br />
IN3<br />
IN4<br />
O1<br />
O2<br />
O3<br />
O4<br />
U S O<br />
O<br />
Digital<br />
IN<br />
Digital<br />
OUT<br />
IFS-<br />
Port<br />
Logic<br />
µP<br />
T-BUS<br />
Reset<br />
DAT<br />
ERR<br />
P<br />
Thermistor<br />
Type Order No.<br />
Electronic <strong>motor</strong> management<br />
EMM 3- 24DC/500AC-IFS 2297497 1 EMM 3- 24DC/500AC-16-IFS 2297523 1<br />
EMM 3-230AC/500AC-IFS 2297507 1 EMM 3-230AC/500AC-16-IFS 2297536 1<br />
Programming adapter with USB interface, for programming with<br />
the IFS-CONF software<br />
IFS-USB-PROG-ADAPTER 2811271 1 IFS-USB-PROG-ADAPTER 2811271 1<br />
DIN rail connector T-BUS<br />
ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2707437 50 ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2707437 50<br />
Mini COMBICON connectors<br />
- Female contact IMC 1,5/ 5-G-3,81 1862603 50 IMC 1,5/ 5-G-3,81 1862603 50<br />
- Male contact<br />
Technical data<br />
IMC 1,5/ 5-ST-3,81 1857919 50 IMC 1,5/ 5-ST-3,81 1857919<br />
Input data EMM 3- 24DC/500AC-IFS EMM 3-230AC/500AC-IFS EMM 3- 24DC/500AC-16-IFS EMM 3-230AC/500AC-16-IFS<br />
Rated control supply voltage US 24 V DC 230 V AC 24 V DC 230 V AC<br />
Rated control supply voltage range with reference to US 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />
Rated control supply current I S at U S 25 mA 10 mA 25 mA 10 mA<br />
Operating voltage / status / error indicator LED green / LED yellow right rotation (R), LED yellow left rotation<br />
(L), LED green data communication / LED red<br />
L<br />
R<br />
V1<br />
V2<br />
V3<br />
I11<br />
I21<br />
I31<br />
I12<br />
I22<br />
I32<br />
Th1<br />
Th2<br />
Pcs. /<br />
Pkt.<br />
LED green / LED yellow right rotation (R), LED yellow left rotation<br />
(L), LED green data communication / LED red<br />
Thermistor input 1 - 6 thermistors in series 1 - 6 thermistors in series<br />
Input data of digital inputs EMM 3- 24DC/500AC-IFS EMM 3-230AC/500AC-IFS EMM 3- 24DC/500AC-16-IFS EMM 3-230AC/500AC-16-IFS<br />
Number of inputs 4 (IN1 - IN4) 4 (IN1 - IN4) 4 (IN1 - IN4) 4 (IN1 - IN4)<br />
Rated actuating voltage U C 24 V DC 230 V AC 24 V DC 230 V AC<br />
Rated actuating current I C 3.3 mA 3.5 mA 3.3 mA 3.5 mA<br />
Power measurement<br />
Voltage measuring input 42 V AC ... 575 V AC 42 V AC ... 575 V AC 42 V AC ... 575 V AC 42 V AC ... 575 V AC<br />
Nominal current, voltage measuring input < 0.5 mA < 0.5 mA - -<br />
Current measuring input 5 A Secondary external converter 5 A Secondary external converter Max. 16 A Max. 16 A<br />
Output power of the converter > 1.25 VA > 1.25 VA - -<br />
Internal resistance EMM 0.02 Ω 0.02 Ω - -<br />
Output data for confirmation contacts<br />
O1 - O4 in the case of 1 signal 24 V DC (Short-circuit-proof<br />
semiconductor output) / 500 mA<br />
EMM 3-.../500AC<br />
Electronic <strong>motor</strong> management<br />
for use of external current transformers<br />
230 V AC (Relay output; Ag<br />
alloy, hard gold-plated) / 500 mA<br />
D<br />
H W<br />
EMM 3-.../500AC-16<br />
Electronic <strong>motor</strong> management,<br />
with integrated current transformers<br />
24 V DC (Short-circuit-proof<br />
semiconductor output) / 500 mA<br />
General data<br />
Rated insulation voltage 500 V 500 V<br />
Rated surge voltage 8 kV 8 kV 8 kV 8 kV<br />
Ambient temperature range -25 °C ... 70 °C -25 °C ... 70 °C<br />
St<strong>and</strong>ards/regulations EN 60947 / EN 60947-4-2 EN 60947 / EN 60947-4-2<br />
Power station requirements DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />
EMC regulations EN 61000-6-2 / EN 61000-6-3 / EN 61000-6-4 EN 61000-6-2 / EN 61000-6-3 / EN 61000-6-4<br />
Degree of protection in acc. with IEC 60529/ EN 60529 IP20 IP20<br />
Mounting position Panel mounting on horizontal DIN rail Panel mounting on horizontal DIN rail<br />
Assembly In rows with zero spacing In rows with zero spacing<br />
Dimensions W / H / D 22.5 mm / 114.5 mm / 99 mm 22.5 mm / 114.5 mm / 99 mm<br />
12 PHOENIX CONTACT<br />
230 V AC (Relay output; Ag<br />
alloy, hard gold-plated) / 500 mA
Electronic <strong>motor</strong> management<br />
Module<br />
power supply<br />
US IN1 IN2 IN3 IN4<br />
IN1 IN2 IN3 IN4<br />
EMM 3-.../500AC-16-IFS<br />
L1<br />
L2<br />
L3<br />
EMM 3-.../500AC-IFS<br />
O UO O1 O2 O3 O4 O UO O1 O2 O3 O4<br />
Th1<br />
S<br />
Power supply<br />
Digital<br />
outputs<br />
Digital<br />
inputs<br />
Digital<br />
outputs<br />
Th1<br />
Th2<br />
Thermistor<br />
input<br />
1/L1<br />
2/T1<br />
3/L2<br />
4/T2<br />
5/L3<br />
Current measurement<br />
Current measurement<br />
The electronic <strong>motor</strong> management<br />
modules offer all the advantages of modern<br />
effective power monitoring. Every 6.6 ms,<br />
the effective power of a drive system or of<br />
any other 3-phase consumer is calculated<br />
from three currents, voltages <strong>and</strong> the phase<br />
angle. Currents of up to 16 A can be directly<br />
acquired <strong>and</strong> currents >16 A are supplied<br />
via external converters. Digital outputs can<br />
be used to control separate mechanical or<br />
electronic switching elements that adopt<br />
the actual switching of the load. In this<br />
configuration, the EMM reliably protects<br />
connected loads – irrespective of their<br />
power consumption – against overload <strong>and</strong><br />
underload, <strong>and</strong> provides permanent status<br />
monitoring.<br />
Up to 8 freely parameterizable switching,<br />
message thresholds <strong>and</strong> up to four freely<br />
configurable inputs <strong>and</strong> outputs enable the<br />
protection of electrical drives <strong>and</strong> the<br />
system.<br />
6/T3<br />
U S<br />
S<br />
Reverse running<br />
1/L1 3/L2 5/L3<br />
Reverse running<br />
1/L1 3/L2 5/L3<br />
Separate switching module<br />
Separate switching module<br />
Forward running<br />
GND<br />
2/T1 4/T2 6/T3<br />
Forward running<br />
GND<br />
2/T1 4/T2 6/T3<br />
M<br />
Module<br />
power supply<br />
Power supply<br />
Digital<br />
outputs<br />
Digital<br />
inputs<br />
Digital<br />
outputs<br />
The EMM modules can record the<br />
following data:<br />
– Apparent, effective <strong>and</strong> reactive power,<br />
– Currents <strong>and</strong> voltages,<br />
– Phase angle,<br />
– Switching-cycle <strong>and</strong> operating-hours,<br />
–Power meter.<br />
Additional Functions:<br />
– Adjustable bimetal function class 5-30<br />
– Thermistor monitor<br />
– Recording measured values<br />
– Profibus connection via TBUS<br />
– Pre-configured <strong>motor</strong> exits such as<br />
reversing starters, star delta starters, etc.<br />
The EMM modules can be used to record<br />
complete "curves" that can be used for<br />
system documentation.<br />
The operating modes right <strong>and</strong> left<br />
rotation, reverse <strong>and</strong> limit switch operation<br />
(with integrated restart inhibit) switch<br />
actuating <strong>and</strong> regulating drives, pumps etc.<br />
<strong>and</strong> also check for wear.<br />
V1<br />
V2<br />
V3<br />
Voltage<br />
measurement<br />
Th2<br />
Thermistor<br />
input<br />
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
I11<br />
I12<br />
I21<br />
I22<br />
M<br />
I31<br />
Current<br />
measurement<br />
Current<br />
measurement<br />
I32<br />
S1/k<br />
S2/l<br />
P1<br />
P2<br />
S1/k<br />
S2/l<br />
P1<br />
P2<br />
S1/k<br />
Current transformer<br />
The external converters should be<br />
selected with a secondary nominal current<br />
of 5 A. The primary current is determined<br />
by the current consumption of the<br />
consumer (refer to connection diagram).<br />
For suitable current transformers, see<br />
catalog INTERFACE.<br />
DIN rail connector T-BUS<br />
The T-BUS (Order No. 2707437 ) can be<br />
used to supply several EMMs with 24 V DC<br />
or to connect up to 32 EMMs to the<br />
PROFIBUS-gateway.<br />
Switching element<br />
Depending on the particular requirement<br />
of the application, either an electromechanical<br />
contactor or reversing<br />
contactor combination, or a solid-<strong>state</strong><br />
contactor or a solid-<strong>state</strong> reversing<br />
contactor is to be used for the actual task of<br />
switching the load. These switching<br />
elements are controlled via the digital<br />
outputs of the EMM modules.<br />
S2/l<br />
P1<br />
P2<br />
PHOENIX CONTACT 13
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
PROFIBUS gateway for the electronic<br />
<strong>motor</strong> management modules<br />
The EM-PB-GATEWAY-IFS is a module<br />
that enables a connection of the EMM...IFS<br />
modules to the PROFIBUS-DP.<br />
The module is certified in acc. with the<br />
DPV 1 specification (EN 50170).<br />
The EM-PB-GATEWAY-IFS can<br />
communicate with up to 32 EMM...IFS<br />
modules via the T-BUS. 8 digital inputs <strong>and</strong><br />
4 outputs can be freely parameterized.<br />
Moreover, the EM-PB-GATEWAY-IFS<br />
supports Fail Safe: The switching behavior in<br />
the event of PROFIBUS errors can be<br />
influenced by the parameterization. Digital<br />
switching outputs enable direct connection<br />
of the EMM...IFS (forward running/reverse<br />
running).<br />
The GSD file (with the communication<br />
characteristics of a PROFIBUS-DP device)<br />
can be found on the Internet under<br />
www.phoenixcontact.net/download.<br />
14 PHOENIX CONTACT<br />
Connection data solid str<strong>and</strong>ed<br />
[mm 2 ] AWG<br />
0.2-2.5 0.2-2.5 24-12<br />
B-Line 3<br />
RTS 4<br />
GND PB 5<br />
5V PB 6<br />
A-Line 8<br />
US GND<br />
24V IFS-<br />
DC Port<br />
PB<br />
Reset<br />
µController<br />
EPROM<br />
IN<br />
TO<br />
USO OUT<br />
Description Type Order No.<br />
PROFIBUS Master gateway for the INTERFACE system<br />
With screw connection<br />
Programming adapter with USB interface, for programming with<br />
the IFS-CONF software<br />
EM-PB-GATEWAY-IFS 2297620 1<br />
DIN rail connector T-BUS<br />
IFS-USB-PROG-ADAPTER 2811271 1<br />
Mini COMBICON connectors<br />
ME 22,5 TBUS 1,5/ 5-ST-3,81 GN 2707437 50<br />
- Female contact IMC 1,5/ 5-G-3,81 1862603 50<br />
- Male contact<br />
Technical data<br />
Input data<br />
IMC 1,5/ 5-ST-3,81 1857919 50<br />
Operating voltage UB 24 V DC -20 % ... +25 %<br />
Nominal input current at UIN 85 mA<br />
Input circuit<br />
Digital inputs<br />
Polarity protection, surge protection<br />
Input voltage 24 V DC ±20 %<br />
Nominal input current at UIN 3 mA<br />
Input circuit<br />
Digital outputs<br />
Polarity protection, surge protection<br />
Maximum switching voltage 23 V DC (UB - Uresid. of the output)<br />
Max. switching current 500 mA<br />
Residual voltage 1 V<br />
Output protection<br />
IFS interface<br />
Parallel protection against polarity reversal, pay attention to the fuse<br />
Type of connection<br />
PROFIBUS interface<br />
T-BUS<br />
Data rate 12 MBit/s<br />
Type of connection<br />
General data<br />
D-SUB-9<br />
Test voltage data interface/power supply 1.5 kV<br />
Ambient temperature (operation) -35 °C ... 50 °C<br />
Rated operating mode 100% operating factor<br />
St<strong>and</strong>ards/regulations EN 50178<br />
Degree of protection IP20<br />
Assembly position/mounting Any / -<br />
Dimensions W / H / D 22.5 mm / 114.5 mm / 99 mm<br />
D<br />
H W<br />
Width 22.5 mm<br />
EM-PB-GATEWAY-IFS<br />
PROFIBUS gateway<br />
Status<br />
IFS<br />
IN1<br />
IN2<br />
IN3<br />
IN4<br />
IN5<br />
IN6<br />
IN7<br />
IN8<br />
O1<br />
O2<br />
O3<br />
O4<br />
TBUS<br />
Pcs. /<br />
Pkt.
PROFIBUS gateway for the electronic<br />
<strong>motor</strong> management modules<br />
EM-PB gateway<br />
+ EMM ... IFS<br />
Startup<br />
(DPM2)<br />
Device Type Manager (DTM) for<br />
<strong>motor</strong> management modules<br />
EMM...IFS<br />
– <strong>CONTACTRON</strong>-DTM-IFS, programming<br />
adapter, manual <strong>and</strong> Quick Start Guide<br />
for the EMM..IFS system as configuration<br />
package available<br />
– Also available as USB programming<br />
adapter even individually<br />
– <strong>CONTACTRON</strong>-DTM-IFS available even<br />
for free download as an individual unit<br />
under www.phoenixcontact.com<br />
Diagnostics/maintenance<br />
(DPM2)<br />
....<br />
EM-PB gateway + EMM ... IFS 1<br />
up to EMM ... IFS 31, EMM ... IFS 32<br />
Control (PLC)<br />
(DPM1)<br />
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
MM-CONF-SET<br />
Description Type Order No.<br />
Configuration packet for the EMM...IFS, consisting of<br />
<strong>CONTACTRON</strong>-DTM-IFS, USB programming adapter, manual<br />
<strong>and</strong> Quick Start Guide<br />
Programming adapter with USB interface, for programming with<br />
the IFS-CONF software<br />
Pcs. /<br />
Pkt.<br />
MM-CONF-SET 2297992 1<br />
IFS-USB-PROG-ADAPTER 2811271 1<br />
PHOENIX CONTACT 15
The “4 in 1” reversing contactor –<br />
No wider than your thumb!<br />
A traditional reversing circuit comprises a<br />
reversing contactor combination <strong>and</strong> a <strong>motor</strong><br />
protection relay. An additional emergency<br />
stop contactor arrangement is also often<br />
necessary to meet mechanical engineering<br />
safety requirements.<br />
All of these functions have been integrated<br />
for <strong>motor</strong>s with an engine power of up<br />
to 4 kW in the new “4 in 1” 22.5 mm<br />
solid-<strong>state</strong> reversing contactor from the<br />
<strong>CONTACTRON</strong> product range. Installation<br />
is simplified considerably <strong>and</strong> a significant<br />
amount of space is saved on the DIN rail.<br />
System availability is maximized by the nearly<br />
wear-free switching ability of the <strong>contactors</strong>.<br />
22.5 mm<br />
16 PHOENIX CONTACT<br />
No wider than your<br />
thumb! Try it!<br />
1. Left rotation<br />
Easy control via a 24 V DC or a<br />
230 V AC signal. Locking circuit<br />
<strong>and</strong> load wiring included.<br />
3. Motor protection<br />
Easy protection using the<br />
electronic <strong>motor</strong> protection<br />
relay with an automatic <strong>and</strong><br />
remote reset function.
The advantages:<br />
75% less space required<br />
75% less wiring time<br />
Service life ten times longer<br />
Integrated safety function<br />
2. Right rotation<br />
Easy control via a 24 V DC or a<br />
230 V AC signal. Locking circuit<br />
<strong>and</strong> load wiring included.<br />
SIL 3<br />
IEC 61508<br />
PL e<br />
ISO 13849-1<br />
Kat.3<br />
EN 954-1<br />
4. Emergency stop<br />
Integrated safety function for<br />
use in safety applications.<br />
PHOENIX CONTACT 17
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
Three-phase "4 in 1" solid-<strong>state</strong><br />
reversing <strong>contactors</strong><br />
The 22.5 mm wide three-phase "4 in 1"<br />
solid-<strong>state</strong> reversing <strong>contactors</strong> with<br />
current monitoring combine four functions<br />
into one: Right contactor, left contactor,<br />
<strong>motor</strong> protection relay <strong>and</strong> EMERGENCY<br />
STOP up to category 3.<br />
The devices have the following<br />
advantages:<br />
– They save wiring<br />
– Bi-metal function settable up to 9 A<br />
– Long service life<br />
Safety level as per<br />
– IEC 61508-1 :SIL3<br />
– ISO 13849:PL e<br />
– EN 954-1:Category 3<br />
Notes:<br />
Type of housing:<br />
Polyamide PA non-reinforced, color: green.<br />
solid str<strong>and</strong>ed I U<br />
[mm 2 ] AWG [A] [V]<br />
Screw connection 0.14-2.5 0.14-2.5 26-12<br />
D<br />
H W<br />
MAN<br />
RES<br />
AUTO<br />
Us Us GND<br />
GNDE<br />
R<br />
L<br />
ELR W 3-.../500AC-2I<br />
"4 in 1" <strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />
for reversing 3~ AC <strong>motor</strong>s up to 550 V AC/3 x 2 A<br />
RES<br />
U j x v<br />
Ex: X p // Applied for: UL-EX LIS / CUL-EX LIS / GL / NV<br />
Logik<br />
µP<br />
& Error<br />
97 96 95<br />
Description Type Order No.<br />
1/L1<br />
3/L2<br />
5/L3<br />
2/T1<br />
4/T2<br />
6/T3<br />
Pcs. /<br />
Pkt.<br />
D<br />
H W<br />
MAN<br />
RES<br />
AUTO<br />
Us Us GND<br />
GNDE<br />
R<br />
L<br />
ELR W 3-.../500AC-9I<br />
"4 in 1" <strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />
for reversing 3~ AC <strong>motor</strong>s up to 550 V AC/3 x 9 A<br />
RES<br />
Logik<br />
µP<br />
& Error<br />
97 96 95<br />
Type Order No.<br />
"4 in 1" <strong>Solid</strong>-<strong>state</strong> reversing contactor<br />
ELR W3- 24DC/500AC- 2I 2297031 1 ELR W3- 24DC/500AC- 9I 2297057 1<br />
ELR W3-230AC/500AC- 2I 2297044 1 ELR W3-230AC/500AC- 9I 2297060 1<br />
Technical data<br />
Input data ELR W3- 24DC/500AC- 2I ELR W3-230AC/500AC- 2I ELR W3- 24DC/500AC- 9I ELR W3-230AC/500AC- 9I<br />
Rated control supply voltage US 24 V DC 230 V AC 24 V DC 230 V AC<br />
Rated control supply voltage range with reference to US 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />
Rated control supply current I S at U S 35 mA 3.5 mA 35 mA 3.5 mA<br />
Rated actuation voltage U C R/L 24 V DC 230 V AC 24 V DC 230 V AC<br />
Rated actuating voltage range with reference to U C 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />
U j x v<br />
Ex: X p // Applied for: UL-EX LIS / CUL-EX LIS / GL / NV<br />
Rated actuating current IC at UC 3 mA 7 mA 3 mA 7 mA<br />
Input circuit Polarity protection ,<br />
Surge protection Polarity protection ,<br />
Surge protection<br />
Surge protection<br />
Surge protection<br />
Operating voltage / status / error indicator<br />
Output data load side<br />
LED green / Yellow LED / LED red LED green / Yellow LED / LED red<br />
Output voltage range 48 V AC ... 550 V AC 48 V AC ... 550 V AC 48 V AC ... 550 V AC 48 V AC ... 550 V AC<br />
Load current Max. 2.4 A (see derating curve) Max. 2.4 A (see derating curve) Max. 9 A (see derating curve) Max. 9 A (see derating curve)<br />
Surge current 100 A (t = 10 ms) 100 A (t = 10 ms) 100 A (t = 10 ms) 100 A (t = 10 ms)<br />
Min. load current 180 mA 180 mA 1.2 A 1.2 A<br />
Residual voltage < 0.3 V < 0.3 V < 0.5 V < 0.5 V<br />
Leakage current 0 mA 0 mA 0 mA 0 mA<br />
Output protection<br />
General data<br />
Surge protection Surge protection<br />
Rated insulation voltage 500 V 500 V<br />
Rated surge voltage 6 kV 4 kV 6 kV 4 kV<br />
Reversing frequency Max. 2 Hz Max. 2 Hz Max. 2 Hz Max. 2 Hz<br />
Ambient temperature range -25 °C ... 70 °C -25 °C ... 70 °C<br />
Electrical service life 3 x 107 cycles 3 x 107 cycles<br />
St<strong>and</strong>ards/regulations DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947<br />
Power station requirements DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />
Degree of protection in acc. with IEC 60529/ EN 60529 IP20 IP20<br />
Mounting position optional (Observe derating) optional (Observe derating)<br />
Assembly Can be aligned with spacing = 20 mm Can be aligned with spacing = 20 mm<br />
Dimensions W / H / D 22.5 mm / 114.5 mm / 99 mm 22.5 mm / 114.5 mm / 99 mm<br />
Safety data<br />
EU type-examination certificate in acc. with ATEX X II (2) GD<br />
X II (2) GD<br />
X II (2) GD<br />
X II (2) GD<br />
PTB 07 ATEX 3145<br />
PTB 07 ATEX 3145<br />
PTB 07 ATEX 3145<br />
PTB 07 ATEX 3145<br />
Category in acc. with EN 954-1 3 3 3 3<br />
18 PHOENIX CONTACT<br />
1/L1<br />
3/L2<br />
5/L3<br />
2/T1<br />
4/T2<br />
6/T3<br />
Pcs. /<br />
Pkt.
Conventional structure<br />
Control current path for reversing contactor as per category 3<br />
+24V DC F5<br />
GND<br />
F 4<br />
T 1<br />
T 2<br />
K 3<br />
K 4<br />
K 4<br />
K 3<br />
K 5<br />
S 2<br />
K1 + K2 = EMERGENCY STOP contactor<br />
K3 = Left contactor<br />
K4 = Right contactor<br />
K5 = PSR SCP-24DC.../safety relay<br />
T1 = Left, T2 = Right, T3 = Reset<br />
S2 = EMERGENCY STOP<br />
F4 = Motor protection relay<br />
T 3<br />
K 5<br />
K 5<br />
K 1<br />
K 2<br />
K 5<br />
K 5<br />
K 5<br />
K 5<br />
K 5<br />
K 1<br />
K 5<br />
K 2<br />
Output current [O]<br />
Conventional structure<br />
Main current path for reversing contactor as per category 3<br />
L1<br />
L2<br />
L3<br />
F1<br />
F2<br />
F3<br />
K 1<br />
K 2<br />
K 3<br />
F 4<br />
M<br />
3~<br />
M1 K 4<br />
PE<br />
K1 + K2 = EMERGENCY STOP contactor<br />
K3 = Left contactor<br />
K4 = Right contactor<br />
F4 = Motor protection relay<br />
4<br />
3,5<br />
3<br />
2,5<br />
2<br />
1,5<br />
1<br />
0,5<br />
0,18<br />
0<br />
10 20 30 40 50 60 70<br />
Ambient temperature [°C]<br />
Derating curve ELR W 3-24DC/500AC-2I<br />
Operating time 100%<br />
Output current [O]<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0,18<br />
0<br />
2<br />
2<br />
1<br />
10 20 30 40 50 60 70<br />
Ambient temperature [°C]<br />
Derating curve ELR W 3-24DC/500AC-9I<br />
Operating time 100%<br />
1 aligned with > 20 mm spacing<br />
2 aligned without spacing<br />
1<br />
Structure with <strong>CONTACTRON</strong><br />
Main <strong>and</strong> control current path for "4 in 1" reversing contactor as<br />
per category 3<br />
F1<br />
L1<br />
F2<br />
L2<br />
F3<br />
L3<br />
+24V DC<br />
GND<br />
4<br />
3,5<br />
3<br />
2,5<br />
2<br />
1,5<br />
1<br />
0,5<br />
0,18<br />
0<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0,18<br />
0<br />
L1 L2 L3<br />
K1 T1 T2 T3<br />
T1 T2<br />
M<br />
3~<br />
M1 K1 +US R L<br />
K5 E<br />
PE<br />
K 5<br />
K1 = "4 in 1" solid-<strong>state</strong> reversing contactor<br />
K5 = PSR SCP-24DC.../safety relay<br />
T1 = Left, T2 = Right, T3 = Reset<br />
S2 = EMERGENCY STOP<br />
Output current [O]<br />
Output current [O]<br />
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
2<br />
S 2<br />
T 3<br />
K 5<br />
K 5<br />
1<br />
K 5<br />
K 5<br />
10 20 30 40 50 60 70<br />
Ambient temperature [°C]<br />
Derating curve ELR W 3-230AC/500AC-2I<br />
Operating time 100%<br />
2<br />
1<br />
10 20 30 40 50 60 70<br />
Ambient temperature [°C]<br />
Derating curve ELR W 3-230AC/500AC-9I<br />
Operating time 100%<br />
K 5<br />
K 5<br />
PHOENIX CONTACT 19
<strong>CONTACTRON</strong> –<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> <strong>and</strong><br />
reversing <strong>contactors</strong><br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> are greatly superior<br />
to mechanical <strong>contactors</strong> with regard<br />
to switching speed, service life <strong>and</strong><br />
ruggedness. Even in dusty or chemically<br />
aggressive atmospheres, they work reliably<br />
with stable switching times. They switch<br />
Ohmic <strong>and</strong> inductive loads, e.g. in conveying<br />
equipment, lighting systems, temperature<br />
control systems or production machines,<br />
noiselessly <strong>and</strong> wear-free.<br />
The solid-<strong>state</strong> <strong>contactors</strong> from the<br />
<strong>CONTACTRON</strong> series are available for<br />
1- <strong>and</strong> 3-phase networks <strong>and</strong> also offer a<br />
reversing function, depending on the type.<br />
ELR 1…<br />
Fully electronic, wearfree<br />
switching of currents<br />
up to 50 A for 1-phase<br />
loads.<br />
20 PHOENIX CONTACT<br />
Left rotation<br />
Easy control via a 24 V DC or a<br />
230 V AC signal. Locking circuit<br />
<strong>and</strong> load wiring included.<br />
<strong>Solid</strong>-<strong>state</strong> <strong>contactors</strong> offer real advantages:<br />
1. Fast:<br />
High switching frequencies make short cycle<br />
times, <strong>and</strong> therefore high productivity, possible.<br />
2. Durable:<br />
Wear-free <strong>and</strong> reliable switching with no contact<br />
bounce prevents system failures.<br />
3. Robust:<br />
Immunity to shocks, vibrations <strong>and</strong> aggressive<br />
ambient conditions allows them to be used in<br />
harsh environments.
ELR 3/ELR W 3...<br />
Fully electronic, wear-free<br />
switching for 3-phase loads<br />
up to 18.5 kW with reversing<br />
function, depending on the type.<br />
The advantages:<br />
Fast<br />
Durable<br />
Robust<br />
Right rotation<br />
Easy control via a 24 V DC or a<br />
230 V AC signal. Locking circuit<br />
<strong>and</strong> load wiring included.<br />
PHOENIX CONTACT 21
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
Single-phase solid-<strong>state</strong> <strong>contactors</strong><br />
Single-phase solid-<strong>state</strong> <strong>contactors</strong> are<br />
used in AC voltage networks wherever<br />
silent switching, high switching frequencies<br />
<strong>and</strong> a practically unlimited service life are<br />
required.<br />
The sturdy power semi-conductors<br />
switch in zero voltage crossing <strong>and</strong> thus<br />
produce no additional high frequency<br />
interferences. The modules are insensitive<br />
to shock loads <strong>and</strong> vibrations – even use in<br />
aggressive, polluted environments is<br />
unproblematic.<br />
They offer the following advantages:<br />
– High switching frequency<br />
– wear-free <strong>and</strong> output-free,<br />
– Input voltage versions 24 V DC <strong>and</strong><br />
230 V AC.<br />
Common areas of application are:<br />
–Production machines,<br />
– Temperature controllers,<br />
– Conveyor equipment <strong>and</strong><br />
– Lighting systems.<br />
Output current[A]<br />
50<br />
40<br />
30<br />
20<br />
10 11<br />
28,5<br />
16<br />
10<br />
20<br />
Ambient temperature [°C]<br />
Load current as a function of the ambient temperature<br />
Operating time: 100% operating factor<br />
40<br />
22 PHOENIX CONTACT<br />
60<br />
Notes:<br />
Type of housing:<br />
Polycarbonate PC, color: green.<br />
For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />
H W<br />
ELR 1-.../600AC-20<br />
Single-phase solid-<strong>state</strong> contactor<br />
Description Type Order No.<br />
Single-phase solid-<strong>state</strong> contactor<br />
ELR 1- 24DC/600AC-20 2297138 1<br />
ELR 1-230AC/600AC-20 2297141 1<br />
Technical data<br />
Input data ELR 1- 24DC/600AC-20 ELR 1-230AC/600AC-20<br />
Input voltage range 4 V DC ... 32 V DC 24 V AC ... 275 V AC<br />
Typ. input current at UN Approx. 12 mA Approx. 17 mA<br />
Switching level 1 signal ("H") ≥ 4 V DC ≥ 22 V AC<br />
0 signal ("L") ≤ 1 V DC ≤ 6 V AC<br />
Transmission frequency flimit 25 Hz 6 Hz<br />
Operating voltage / status / error indicator<br />
Output data load side<br />
LED green / - / -<br />
Output voltage range 42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz)<br />
Periodic peak reverse voltage 1200 V 1200 V<br />
Load current 20 A (see derating curve) 20 A (see derating curve)<br />
Surge current 250 A (t = 10 ms) 250 A (t = 10 ms)<br />
Min. load current 350 mA 350 mA<br />
Residual voltage < 1.6 V < 1.6 V<br />
Leakage current < 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>)<br />
Phase angle (cos ϕ) 0.5 0.5<br />
Max. load value I 2 x t (t = 10 ms) 525 A 2 s 525 A 2 s<br />
Output protection RCV circuit<br />
General data<br />
Test voltage input/output 4 kV rms<br />
Ambient temperature range -30 °C ... 70 °C<br />
St<strong>and</strong>ards/regulations EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN<br />
61000-4-6 / EN 55011<br />
Mounting position Vertical (horizontal DIN rail)<br />
Assembly Can be aligned with ≥ 22.5 mm spacing<br />
Dimensions W / H / D 22.5 mm / 103 mm / 103 mm<br />
A1<br />
+<br />
A2<br />
-<br />
D<br />
Zero voltage<br />
switch<br />
u<br />
1/L1<br />
2/T1<br />
Pcs. /<br />
Pkt.
A1<br />
+<br />
A2<br />
-<br />
D<br />
H W<br />
ELR 1-.../600AC-30<br />
Single-phase solid-<strong>state</strong> contactor<br />
Zero voltage<br />
switch<br />
Type Order No.<br />
1/L1<br />
2/T1<br />
Pcs. /<br />
Pkt.<br />
D<br />
H W<br />
A1<br />
+<br />
A2<br />
-<br />
ELR 1-.../600AC-50<br />
Single-phase solid-<strong>state</strong> contactor<br />
u u<br />
Type Order No.<br />
ELR 1- 24DC/600AC-30 2297154 1 ELR 1- 24DC/600AC-50 2297170 1<br />
ELR 1-230AC/600AC-30 2297167 1 ELR 1-230AC/600AC-50 2297183 1<br />
ELR 1- 24DC/600AC-30 ELR 1-230AC/600AC-30 ELR 1- 24DC/600AC-50 ELR 1-230AC/600AC-50<br />
4 V DC ... 32 V DC 24 V AC ... 275 V AC 4 V DC ... 32 V DC 24 V AC ... 275 V AC<br />
Approx. 12 mA Approx. 17 mA Approx. 12 mA Approx. 17 mA<br />
≥ 4 V DC ≥ 22 V AC ≥ 4 V DC ≥ 22 V AC<br />
≤ 1 V DC ≤ 6 V AC ≤ 1 V DC ≤ 6 V AC<br />
25 Hz 6 Hz 25 Hz 6 Hz<br />
LED green / - / - LED green / - / -<br />
42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz) 42 V AC ... 660 V AC (45/65 Hz)<br />
1200 V 1200 V 1200 V 1200 V<br />
30 A (see derating curve) 30 A (see derating curve) 50 A (see derating curve) 50 A (see derating curve)<br />
400 A (t = 10 ms) 400 A (t = 10 ms) 1900 A (t = 10 ms) 1900 A (t = 10 ms)<br />
150 mA 150 mA 150 mA 150 mA<br />
< 1.6 V < 1.6 V < 1.6 V < 1.6 V<br />
< 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>) < 3 mA (In off <strong>state</strong>)<br />
0.5 0.5 0.5 0.5<br />
1800 A 2 s 1800 A 2 s 18000 A 2 s 18000 A 2 s<br />
RCV circuit RCV circuit<br />
4 kVrms 4 kVrms -30 °C ... 70 °C -30 °C ... 70 °C<br />
EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN EN 61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN<br />
61000-4-6 / EN 55011<br />
61000-4-6 / EN 55011<br />
Vertical (horizontal DIN rail) Vertical (horizontal DIN rail)<br />
Can be aligned with ≥ 22.5 mm spacing Can be aligned with ≥ 22.5 mm spacing<br />
22.5 mm / 103 mm / 103 mm 45 mm / 103 mm / 103 mm<br />
Zero voltage<br />
switch<br />
1/L1<br />
2/T1<br />
Pcs. /<br />
Pkt.<br />
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
PHOENIX CONTACT 23
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
Three-phase solid-<strong>state</strong> contactor<br />
Motors of mixers, machine tools,<br />
conveying systems, pumps <strong>and</strong> fans up to<br />
575 V AC/3x37 A (equivalent to 1 kW to<br />
18.5 kW) can be controlled using the<br />
<strong>CONTACTRON</strong> three-phase solid-<strong>state</strong><br />
<strong>contactors</strong>.<br />
Advantages of three-phase solid-<strong>state</strong><br />
<strong>contactors</strong>:<br />
– Noise-free <strong>and</strong> wear-free switching<br />
– Integrated protective circuit<br />
– Stable <strong>and</strong> short switching times<br />
– Long service life<br />
– High switching frequency<br />
– Thermal fuse optional (on request)<br />
Output current[A]<br />
Output current[A]<br />
10<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
45<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
10<br />
10<br />
ELR ...-9<br />
ELR ...-2<br />
20<br />
ELR ...-37<br />
ELR ...-16<br />
20<br />
40<br />
40<br />
60<br />
Ambient temperature [°C]<br />
Load current as a function of the ambient temperature<br />
Operating time: 100% operating factor<br />
60<br />
Ambient temperature [°C]<br />
Load current as a function of the ambient temperature<br />
Operating time: 100% operating factor<br />
24 PHOENIX CONTACT<br />
Notes:<br />
Type of insulation housing:<br />
ELR 3...2, ELR 3...9<br />
Polyamide PA non-reinforced, color:Green<br />
ELR 3...16, ELR 3...37<br />
Polyester PBT non-reinforced, color:Green<br />
For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />
solid str<strong>and</strong>ed I U<br />
[mm 2 ] AWG [A] [V]<br />
Screw connection 0.14-2.5 0.14-2.5 26-12<br />
D<br />
H W<br />
ON<br />
T<br />
ELR 3-.../500AC-2<br />
Three-phase solid-<strong>state</strong> contactor,<br />
for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 2 A<br />
Applied for:<br />
UL / CUL / UL-EX LIS / CUL-EX LIS<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Description Type Order No.<br />
Three-phase semiconductor contactor<br />
ELR 3- 24DC/500AC- 2 2297196 1<br />
ELR 3-230AC/500AC- 2 2297206 1<br />
Technical data<br />
Input data ELR 3- 24DC/500AC- 2 ELR 3-230AC/500AC- 2<br />
Rated actuation voltage UC ON 24 V DC 230 V AC<br />
Rated actuating voltage range with reference to UC 0.8 ... 1.25 0.4 ... 1.1<br />
Rated actuating current IC at UC 8.3 mA 12.5 mA<br />
Input circuit Polarity protection ,<br />
Surge protection<br />
Surge protection<br />
Operating voltage / status / error indicator<br />
Output data load side<br />
- / Yellow LED / LED red<br />
Output voltage range 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />
Periodic peak reverse voltage 1200 V 1200 V<br />
Load current Max. 2 A (see derating curve) Max. 2 A (see derating curve)<br />
Surge current 200 A (t = 10 ms) 200 A (t = 10 ms)<br />
Min. load current 100 mA 100 mA<br />
Residual voltage < 1.5 V < 1.5 V<br />
Leakage current 6 mA 6 mA<br />
Max. load value I 2 x t (t = 10 ms) 250 A 2s 250 A 2s<br />
Output protection RCV circuit<br />
General data<br />
Rated insulation voltage 500 V<br />
Rated surge voltage 6 kV 6 kV<br />
Switching frequency Max. 10 Hz Max. 1 Hz<br />
Ambient temperature range -25 °C ... 70 °C<br />
St<strong>and</strong>ards/regulations DIN EN 50178 / EN 60947<br />
Power station requirements DWR 1300 / ZXX01/DD/7080.8d<br />
Degree of protection in acc. with IEC 60529/ EN 60529 IP20<br />
Mounting position Horizontal (observe derating)<br />
Assembly Can be aligned with spacing = 20 mm<br />
Dimensions W / H / D 40 mm / 114.5 mm / 99 mm<br />
Pcs. /<br />
Pkt.
D<br />
H W<br />
ON<br />
T<br />
ELR 3-.../500AC-9<br />
Three-phase solid-<strong>state</strong> contactor,<br />
for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3x9 A<br />
Applied for:<br />
UL / CUL / UL-EX LIS / CUL-EX LIS<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Type Order No.<br />
Pcs. /<br />
Pkt.<br />
D<br />
H W<br />
ON<br />
T<br />
ELR 3-.../500AC-16<br />
Three-phase solid-<strong>state</strong> contactor,<br />
for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 16 A<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Type Order No.<br />
Pcs. /<br />
Pkt.<br />
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
D<br />
H W<br />
ON<br />
T<br />
ELR 2+1-.../500AC-37<br />
Three-phase solid-<strong>state</strong> contactor,<br />
for switching 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 37 A<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Type Order No.<br />
ELR 3- 24DC/500AC- 9 2297219 1 ELR 3- 24DC/500AC-16 2297235 1 ELR 2+1- 24DC/500AC-37 2297277 1<br />
ELR 3-230AC/500AC- 9 2297222 1 ELR 3-230AC/500AC-16 2297248 1 ELR 2+1-230AC/500AC-37 2297280 1<br />
ELR 3- 24DC/500AC- 9 ELR 3-230AC/500AC- 9 ELR 3- 24DC/500AC-16 ELR 3-230AC/500AC-16 ELR 2+1- 24DC/500AC-37 ELR 2+1-230AC/500AC-37<br />
24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC<br />
0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />
8.3 mA 12.5 mA 8.3 mA 12.5 mA 8.3 mA 12.5 mA<br />
Polarity protection ,<br />
Surge protection Polarity protection ,<br />
Surge protection Polarity protection ,<br />
Surge protection<br />
Surge protection<br />
Surge protection<br />
Surge protection<br />
- / Yellow LED / LED red - / Yellow LED / LED red - / Yellow LED / LED red<br />
48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />
1200 V 1200 V 1200 V 1200 V 1200 V 1200 V<br />
Max. 9 A (see derating curve) Max. 9 A (see derating curve) Max. 16 A (see derating curve) Max. 16 A (see derating curve) Max. 37 A (see derating curve) Max. 37 A (see derating curve)<br />
300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 1300 A (t = 10 ms) 1300 A (t = 10 ms)<br />
100 mA 100 mA 100 mA 100 mA 200 mA 200 mA<br />
< 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V<br />
6 mA 6 mA 6 mA 6 mA 6 mA 6 mA<br />
580 A 2s 580 A 2s 580 A 2s 580 A 2s 9000 A 2s 9000 A 2s<br />
RCV circuit RCV circuit RCV circuit<br />
500 V 500 V 500 V<br />
6 kV 6 kV 6 kV 6 kV 6 kV 6 kV<br />
Max. 10 Hz Max. 1 Hz Max. 10 Hz Max. 1 Hz Max. 10 Hz Max. 1 Hz<br />
-25 °C ... 70 °C -25 °C ... 70 °C -25 °C ... 70 °C<br />
DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947<br />
DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />
IP20 IP20 IP20<br />
Horizontal (observe derating) Horizontal (observe derating) Horizontal (observe derating)<br />
Can be aligned with spacing = 20 mm Can be aligned with spacing = 40 mm Can be aligned with spacing = 40 mm<br />
67.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm<br />
Pcs. /<br />
Pkt.<br />
PHOENIX CONTACT 25
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
Three-phase solid-<strong>state</strong> reversing<br />
<strong>contactors</strong><br />
The three-phase solid-<strong>state</strong> reversing<br />
<strong>contactors</strong> with an integrated locking circuit<br />
<strong>and</strong> load wiring are intended for applications<br />
such as control valves, slides, separating<br />
filters, ship steering gears, etc. The scope of<br />
performance ranges from 575 V AC/3 x 2 A<br />
to 575 V AC/3 x 37 A.<br />
Advantages of three-phase solid-<strong>state</strong><br />
reversing <strong>contactors</strong>:<br />
– Noise-free <strong>and</strong> wear-free switching<br />
– Integrated protective circuit<br />
– Stable <strong>and</strong> short switching times<br />
– Long service life<br />
– High switching frequency<br />
– Integrated locking <strong>and</strong> load wiring<br />
– Thermal fuse optional (on request)<br />
Output current[A]<br />
Output current[A]<br />
10<br />
9<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
45<br />
40<br />
35<br />
30<br />
25<br />
20<br />
15<br />
10<br />
5<br />
10<br />
10<br />
ELR ...-9<br />
ELR ...-2<br />
20<br />
ELR ...-37<br />
ELR ...-16<br />
20<br />
40<br />
40<br />
60<br />
Ambient temperature [°C]<br />
Load current as a function of the ambient temperature<br />
Operating time: 100% operating factor<br />
60<br />
Ambient temperature [°C]<br />
Load current as a function of the ambient temperature<br />
Operating time: 100% operating factor<br />
26 PHOENIX CONTACT<br />
Notes:<br />
Type of insulation housing:<br />
ELR W 3...2, ELR W 3...9<br />
Polyamide PA non-reinforced, color:Green<br />
ELR W 3...16, ELR W 3...37<br />
Polyester PBT non-reinforced, color:Green<br />
For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />
solid str<strong>and</strong>ed I U<br />
[mm 2 ] AWG [A] [V]<br />
Screw connection 0.14-2.5 0.14-2.5 26-12<br />
D<br />
H W<br />
R<br />
T<br />
L<br />
T<br />
ELR W 3-.../500AC-2<br />
<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />
for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 2 A<br />
Applied for:<br />
UL / CUL / UL-EX LIS / CUL-EX LIS<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Description Type Order No.<br />
<strong>Solid</strong>-<strong>state</strong> reversing contactor<br />
ELR W3- 24DC/500AC- 2 2297293 1<br />
ELR W3-230AC/500AC- 2 2297303 1<br />
Technical data<br />
Input data ELR W3- 24DC/500AC- 2 ELR W3-230AC/500AC- 2<br />
Rated actuation voltage UC R/L 24 V DC 230 V AC<br />
Rated actuating voltage range with reference to UC 0.8 ... 1.25 0.4 ... 1.1<br />
Rated actuating current IC at UC 12.7 mA 11.2 mA<br />
Input circuit Polarity protection ,<br />
Surge protection<br />
Surge protection<br />
Operating voltage / status / error indicator<br />
Output data load side<br />
- / Yellow LED / LED red<br />
Output voltage range 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />
Periodic peak reverse voltage 1200 V 1200 V<br />
Load current Max. 2 A (see derating curve) Max. 2 A (see derating curve)<br />
Surge current 200 A (t = 10 ms) 200 A (t = 10 ms)<br />
Min. load current 100 mA 100 mA<br />
Residual voltage < 1.5 V < 1.5 V<br />
Leakage current 6 mA 6 mA<br />
Max. load value I 2 x t (t = 10 ms) 250 A 2s 250 A 2s<br />
Output protection RCV circuit<br />
General data<br />
Rated insulation voltage 500 V<br />
Rated surge voltage 6 kV 6 kV<br />
Reversing frequency Max. 10 Hz Max. 2 Hz<br />
Switching frequency Max. 5 Hz Max. 1 Hz<br />
Ambient temperature range -25 °C ... 70 °C<br />
St<strong>and</strong>ards/regulations DIN EN 50178 / EN 60947<br />
Power station requirements DWR 1300 / ZXX01/DD/7080.8d<br />
Degree of protection in acc. with IEC 60529/ EN 60529 IP20<br />
Mounting position Horizontal (observe derating)<br />
Assembly Can be aligned with spacing = 20 mm<br />
Dimensions W / H / D 40 mm / 114.5 mm / 99 mm<br />
Pcs. /<br />
Pkt.
D<br />
H W<br />
R<br />
T<br />
L<br />
T<br />
ELR W 3-.../500AC-9<br />
<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />
for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3x9 A<br />
Applied for:<br />
UL / CUL / UL-EX LIS / CUL-EX LIS<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Type Order No.<br />
Pcs. /<br />
Pkt.<br />
D<br />
H W<br />
R<br />
T<br />
L<br />
T<br />
ELR W 3-.../500AC-16<br />
<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />
for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 16 A<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Type Order No.<br />
Pcs. /<br />
Pkt.<br />
INTERFACE Relay<br />
<strong>CONTACTRON</strong> – Power electronics<br />
D<br />
H W<br />
R<br />
T<br />
L<br />
T<br />
ELR W 2+1-.../500AC-37<br />
<strong>Solid</strong>-<strong>state</strong> reversing contactor,<br />
for reversing 3~ AC <strong>motor</strong>s up to 575 V AC/3 x 37 A<br />
1/L1 3/L2 5/L3<br />
2/T1 4/T2 6/T3<br />
Type Order No.<br />
ELR W3- 24DC/500AC- 9 2297316 1 ELR W3- 24DC/500AC-16 2297332 1 ELR W2+1- 24DC/500AC-37 2297374 1<br />
ELR W3-230AC/500AC- 9 2297329 1 ELR W3-230AC/500AC-16 2297345 1 ELR W2+1-230AC/500AC-37 2297387 1<br />
ELR W3- 24DC/500AC- 9 ELR W3-230AC/500AC- 9 ELR W3- 24DC/500AC-16 ELR W3-230AC/500AC-16 ELR W2+1- 24DC/500AC-37 ELR W2+1-230AC/500AC-37<br />
24 V DC 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC<br />
0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1 0.8 ... 1.25 0.4 ... 1.1<br />
12.7 mA 11.2 mA 12.7 mA 11.2 mA 12.7 mA 11.2 mA<br />
Polarity protection ,<br />
Surge protection Polarity protection ,<br />
Surge protection Polarity protection ,<br />
Surge protection<br />
Surge protection<br />
Surge protection<br />
Surge protection<br />
- / Yellow LED / LED red - / Yellow LED / LED red - / Yellow LED / LED red<br />
48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC 48 V AC ... 575 V AC<br />
1200 V 1200 V 1200 V 1200 V 1200 V 1200 V<br />
Max. 9 A (see derating curve) Max. 9 A (see derating curve) Max. 16 A (see derating curve) Max. 16 A (see derating curve) Max. 37 A (see derating curve) Max. 37 A (see derating curve)<br />
300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 300 A (t = 10 ms) 1300 A (t = 10 ms) 1300 A (t = 10 ms)<br />
100 mA 100 mA 100 mA 100 mA 200 mA 200 mA<br />
< 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V < 1.5 V<br />
6 mA 6 mA 6 mA 6 mA 6 mA 6 mA<br />
580 A 2s 580 A 2s 580 A 2s 580 A 2s 9000 A 2s 9000 A 2s<br />
RCV circuit RCV circuit RCV circuit<br />
500 V 500 V 500 V<br />
6 kV 6 kV 6 kV 6 kV 6 kV 6 kV<br />
Max. 10 Hz Max. 2 Hz Max. 10 Hz Max. 2 Hz Max. 10 Hz Max. 2 Hz<br />
Max. 5 Hz Max. 1 Hz Max. 5 Hz Max. 1 Hz Max. 5 Hz Max. 1 Hz<br />
-25 °C ... 70 °C -25 °C ... 70 °C -25 °C ... 70 °C<br />
DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947 DIN EN 50178 / EN 60947<br />
DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d DWR 1300 / ZXX01/DD/7080.8d<br />
IP20 IP20 IP20<br />
Horizontal (observe derating) Horizontal (observe derating) Horizontal (observe derating)<br />
Can be aligned with spacing = 20 mm Can be aligned with spacing = 40 mm Can be aligned with spacing = 40 mm<br />
67.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm 147.5 mm / 114.5 mm / 99 mm<br />
Pcs. /<br />
Pkt.<br />
PHOENIX CONTACT 27
Further information on the products<br />
introduced here <strong>and</strong> on the world of solutions<br />
from <strong>Phoenix</strong> <strong>Contact</strong> can be found at<br />
www.phoenixcontact.net/catalog<br />
Or contact us directly!<br />
PHOENIX CONTACT GmbH & Co. KG<br />
32823 Blomberg, Germany<br />
Phone: +49/52 35/3-00<br />
Fax: +49/52 35/3-1 07 99<br />
www.phoenixcontact.com<br />
Components <strong>and</strong> Systems<br />
AUTOMATION<br />
Industrial Connection Systems,<br />
Marking <strong>and</strong> Mounting Material<br />
CLIPLINE<br />
Connection Technology<br />
for Field Devices <strong>and</strong> Field Cabling<br />
PLUSCON<br />
Device Connection Technology<br />
<strong>and</strong> Electronic Housing<br />
COMBICON<br />
Surge Protection<br />
TRABTECH<br />
Signal Converters, Switching Devices<br />
<strong>and</strong> Power Supplies<br />
INTERFACE<br />
MNR 52003803/11.03.2009-02 Printed in Germany © PHOENIX CONTACT 2009