Dock-Leveller<br />

DIN EN ISO 9001


Leveller in rest position - truck arrives<br />

Leveller in rest position - doors open Leveller rising (lip still down)<br />

Leveller raised - lip extends automatically Leveller raised- lip extended


Close-up of extended lift cylinder<br />

with power pack behind<br />

Close-up of extended lip cylinder<br />

Leveller lowering with lip extended Leveller floating on truck - ready<br />

for un-loading by fork-lift truck


Leveller rising (lip falls automatically) Leveller fully lowered<br />

Leveller fully lowered in rest position - lip in "keepers"


Standard power pack - Roquet Nº 9034030<br />

Main deck lift cylinder - Roquet Nº 9988<br />

Lip cylinder - Roquet Nº 9349


Pedro Roquet, S.A.<br />

A brief introduction to<br />

standard Pedro Roquet<br />

components for hydraulic<br />

dock levellers.<br />

May 2004


Pedro Roquet, S.A.<br />

Roquet power packs for<br />

folding-lip dock levellers<br />

Standard power pack - Roquet Nº 9034030<br />

(metal tank)<br />

Standard power pack - Roquet Nº 2432030<br />

(suitable for single and double lift cylinders)


Pedro Roquet, S.A.<br />

Roquet cylinders for<br />

folding-lip dock levellers<br />

Folding-lip cylinder - Roquet Nº 9349<br />

Single lift cylinder - Roquet Nº 2132<br />

Double lift cylinder - Roquet Nº 2281


Pedro Roquet, S.A.<br />

Roquet components for<br />

extending-lip levellers<br />

Extending / telescopic lip power pack - Roquet Nº 9928020<br />

Extending / telescopic lip cylinder - Roquet Nº 9518<br />

(this version 500mm stroke - also available 1000mm)<br />

Lift cylinders are standard, as previous page


<strong>DOCK</strong> <strong>LEVELLER</strong> <strong>CIRCUIT</strong> FUNCTION<br />

Explanation of function (numbers refer to circuit on page 2):<br />

A. Motor turned on<br />

Page 1 of 2<br />

Pump flow passes through check valve 1 to port A (main deck cylinder).<br />

Pressure rises to that required to lift the deck (let’s assume 80 bar). Pressure maintains pilotoperated<br />

check valve 3 closed. At this stage there is no pressure on the pilot (upper side) of<br />

pilot operated check valve 2 so the lip cylinder is connected directly to tank via the sequence<br />

valve 5 and the p/o check valve 2.<br />

At end of deck cylinder stroke the pressure increases until it reaches the pressure setting of<br />

the lip sequence valve 5 (set 115 bar). This valve then swiches and the lip cylinder raises the<br />

lip. When the lip is completely raised the pressure then increases until it reaches the<br />

pressure setting of the main relief valve 4 (set 140 bar).<br />

B. Motor now turned off<br />

Pressure on the pump-side of check valve 1 falls to zero, allowing p/o check valve 3 to open<br />

which allows fluid to pass from the main deck cylinder to the adjustable lowering valve 7 and<br />

to tank via the energised safety valve 6. The pressure drop created by the returning flow<br />

through the lowering valve 7 also holds shut the p/o check valve 2 so the lip cylinder remains<br />

“up”.<br />

The deck lowers until the lip (still “up”) contacts the truck, which then supports the leveller. At<br />

this stage the p/o check valves 2 and 3 are both open so both cylinders are “floating”.<br />

C. Motor turned on again<br />

Repeat “Motor turned on” section above. Provided motor then turned off again before<br />

reaching end of stroke of main deck cylinder then the lip will not raise and the leveller will<br />

lower into it’s parked position.


<strong>DOCK</strong> <strong>LEVELLER</strong> <strong>POWER</strong>-<strong>PACK</strong> <strong>CIRCUIT</strong><br />

PEDRO ROQUET, S.A.<br />

Antonio Figueras, 91<br />