Maintenance<br />

Press START to initiate R-Cal span calibration. There is not totalization for<br />

three seconds until the weight signal has stabilized. Go to Section 3.10.3.1.4<br />

3.10.3.1.2 Starting a Chain Calibration<br />

Use the following steps to begin a Chain Calibration:<br />

1. Stop the conveyor belt<br />

2. Apply chains on conveyor belt<br />

3. Press SPAN CAL<br />

The following screen displays:<br />

AUTO SPAN CHAIN<br />

Press START to begin<br />

chain calibration.<br />

START EXIT MANUAL<br />

4. Press START to disengage the Master Tons counter.<br />

The following screen displays:<br />

AUTO SPAN CHAIN<br />

Apply chain, then<br />

press START<br />

START EXIT MANUAL<br />

Pressing EXIT or MENU returns the screen to MAIN MENU 1.<br />

5. Press START<br />

The following screen displays:<br />

AUTO SPAN CHAIN<br />

Run belt, then<br />

press START<br />

START EXIT<br />

Password: Operator<br />

Password: Operator<br />

6. Restart conveyor belt and insure chain placement is proper.<br />

7. Press START<br />

8. Continue to Section 3.10.3.1.4<br />

<strong>Thermo</strong> Fisher Scientific Maintenance 3-13<br />