3.6 Normal Power On<br />

Maintenance<br />

When the Integrator is powered on after initial programming, the Run menu is<br />

displayed unless the hardware configuration has been changed.<br />

00000000 TONS<br />

Z 000000 Tph<br />

3.6.1 Hardware Configuration<br />

If the hardware configuration detected at power on differs from the one recorded<br />

in memory, the following screen displays. This only happens if a circuit board<br />

has been added or removed during power off, or a board has failed.<br />

--SLOT # n CHANGED<br />

Acquire new<br />

configuration?<br />

YES NO<br />

This screen disappears after 10 seconds if the question is not answered. The<br />

Integrator assumes the answer is NO. “HW CONFIG. CHANGED” alarm is on<br />

and cannot be reset. The above screen appears each time power is cycled. If a<br />

board is removed or added, and this is a permanent change in configuration,<br />

answer YES.<br />

1. A board is removed and is not replaced:<br />

The Integrator cancels from memory the setup data of the board that is<br />

removed. If the board is added again, the setup data for the board has to be<br />

entered again.<br />

2. A board is added:<br />

The Integrator acquires the new hardware configuration. Setup data for the<br />

new board must be entered.<br />

Note: Check the setup configuration in the I/O DEFINITION SCROLL if an<br />

I/O board is removed or added. I/O assignments change when the number of<br />

I/O boards change.<br />

<strong>Thermo</strong> Fisher Scientific Maintenance<br />

REC 4175 Rev B<br />

3-5