3.1 Overview<br />

Chapter 3<br />

Operation<br />

3.2 Operator Interface<br />

Your <strong>Thermo</strong> Scientific Belt Scale System is capable of accurate weighing,<br />

provided it is installed, calibrated, operated, and maintained in complete<br />

accordance with the instructions contained in this manual, along with our scale<br />

frame installation manual.<br />

Micro-Tech 3101 Integrator is a microcomputer-based instrument that accepts<br />

and conditions speed and weight signals and provides visual and electrical<br />

outputs for total weight and rate of flow. The Integrator produces a stable 10volt<br />

DC excitation voltage capable of exciting up to six strain gauge load cells.<br />

Sense lead terminations are also provided for six wire load cell cables.<br />

Auto Zero Track enables the belt scale system to automatically zero itself during<br />

extended periods when the conveyor belt is running empty. Auto Zero Track is<br />

menu selectable because some installations may not desire this option. A “Z”<br />

displays on the second line of the display to indicate the selection of this option.<br />

Life expectancy of the RAM support battery is approximately ten years, if<br />

power is not applied. Under normal operation where power is on continuously,<br />

life expectancy is much longer.<br />

Errors may occur during initial calibration and their reason must be corrected<br />

during initial calibration. During normal operation, an error would most likely<br />

indicate a failure in system or improper operation.<br />

This section provides information about setting up and operating the Micro-Tech<br />

3101. All operations are performed from the front panel of the electronic<br />

enclosure.<br />

• The operator interface, including all keys, indicators, and displays.<br />

• Procedures for initial setup and calibration are provided. .<br />

• Detailed operating procedures are also included. All operations are<br />

performed from the front panel of the electronic enclosure.<br />

The Micro-Tech 3101 has been adjusted, configured, and inspected at the<br />

factory per the supplied customer data. Additional internal adjustments should<br />

not be necessary for satisfactory performance. If adjustments become necessary,<br />

refer to Chapter 4 Micro-Tech 3101 Maintenance.<br />

<strong>Thermo</strong> Fisher Scientific Maintenance<br />

REC 4175 Rev B<br />

3-1