Your <strong>Thermo</strong> Scientific Belt Scale System is capable of accurate weighing,<br />
provided it is installed, calibrated, operated, and maintained in complete<br />
accordance with the instructions contained in this manual, along with our scale<br />
frame installation manual.<br />
Micro-Tech 3101 Integrator is a microcomputer-based instrument that accepts<br />
and conditions speed and weight signals and provides visual and electrical<br />
outputs for total weight and rate of flow. The Integrator produces a stable 10volt<br />
DC excitation voltage capable of exciting up to six strain gauge load cells.<br />
Sense lead terminations are also provided for six wire load cell cables.<br />
Auto Zero Track enables the belt scale system to automatically zero itself during<br />
extended periods when the conveyor belt is running empty. Auto Zero Track is<br />
menu selectable because some installations may not desire this option. A “Z”<br />
displays on the second line of the display to indicate the selection of this option.<br />
Life expectancy of the RAM support battery is approximately ten years, if<br />
power is not applied. Under normal operation where power is on continuously,<br />
life expectancy is much longer.<br />
Errors may occur during initial calibration and their reason must be corrected<br />
during initial calibration. During normal operation, an error would most likely<br />
indicate a failure in system or improper operation.<br />
This section provides information about setting up and operating the Micro-Tech<br />
3101. All operations are performed from the front panel of the electronic<br />
enclosure.<br />
• The operator interface, including all keys, indicators, and displays.<br />
• Procedures for initial setup and calibration are provided. .<br />
• Detailed operating procedures are also included. All operations are<br />
performed from the front panel of the electronic enclosure.<br />
The Micro-Tech 3101 has been adjusted, configured, and inspected at the<br />
factory per the supplied customer data. Additional internal adjustments should<br />
not be necessary for satisfactory performance. If adjustments become necessary,<br />
refer to Chapter 4 Micro-Tech 3101 Maintenance.<br />