Operation<br />

2-36<br />

2.9.3 Defining the Load Cell(s)<br />

Enter the load cell capacity as it appears on the label placed on the load cell.<br />

-- SC DATA SCROLL -6-<br />

Load cell capacity<br />

250 Lbs<br />

ENTER<br />

If English Default: 250.0 Lbs<br />

or Mixed: Min: 1 Lb<br />

Max: 15000 Lbs<br />

If Metric Default: 100 kg<br />

Min: 1 kg<br />

Max: 5000 kg<br />

The sensitivity was entered when the belt scale code was entered. If other (0)<br />

was selected, enter the load cell sensitivity in mV/V as marked on the label of<br />

the load cell. <strong>Thermo</strong> Scientific load cells are normally 1.800 or 3.000 mV/V.<br />

-- SC DATA SCROLL -7-<br />

Load cell sens.<br />

3.000 mV/V<br />

ENTER<br />

Default: 3.000 mV/V<br />

Min: 0.500 mV/V<br />

Max: 3.500 mV/V<br />

Load cell resistance is entered on this screen. The resistance for the load cell<br />

has been recorded on the System Data Sheet in the front of your belt scale<br />

manual. (It is also stamped on the load cell cable.) Enter the ohms for the load<br />

cell. The number of scrolls depends on the number of load cells specified in<br />

scroll 3O.<br />

-- SC DATA SCROLL –8A-<br />

Load cell #1 res<br />

350.000 Ohms<br />

ENTER<br />

Default: 350 Ohms<br />

Min: 10 Ohms<br />

Max: 2000 Ohms<br />

• If # of Load Cells is more than 2:<br />

Operation <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B