2.9 Defining Dimensional Parameters of the Application<br />

<strong>Thermo</strong> Fisher Scientific Operation<br />

REC 4175 Rev B<br />

Operation<br />

2.9.1 Idler Spacing in Scale Area<br />

Parameter LD: Idler Spacing in Scale Area. For better accuracy, average the<br />

distance between the idlers across the scale on both sides. Measure to within<br />

0.032 inch or 1 mm with the numeric keys and press ENTER.<br />

-- SC DATA SCROLL 4--<br />

Idler spacing<br />

36 In<br />

ENTER<br />

If English Default: 36.00 in<br />

or Mixed: Min: 2.00 in<br />

Max: 120.00 in<br />

If Metric Default: 1000 mm<br />

Min: 50 mm<br />

Max: 2500 mm<br />

2.9.2 Angle of Inclination<br />

Enter the angle of inclination. If an inclination compensator is connected to the<br />

scale, after this preliminary set up has been completed, enable the automatic<br />

angle detection in I/O definition (Main Menu 4) and calibrate the incline<br />

compensator.<br />

-- SC DATA SCROLL -5-<br />

Conveyor’s angle<br />

0.0 Degrees<br />

ENTER +/-<br />

Default: 0.0<br />

Min: -25.00<br />

Max: +25.00<br />

Note: Incline angles greater than 16° are not recommended and generally<br />

restrict the system accuracy. Consult the factory on angles with installation<br />

greater than 16°.<br />