Operation<br />

2-32<br />

• Only if # of weigh idlers > = 4:<br />

-- SC DATA SCROLL 3F--<br />

Pivot to 4 th idler<br />

distance 000.00 IN<br />

ENTER<br />

If English Default: 0.00 in<br />

or Mixed: Min: 0.00 in<br />

Max: 100.00 in<br />

If Metric Default: 0 mm<br />

Min: 0 mm<br />

Max: 2500mm<br />

• Only if # of weigh idlers > = 5:<br />

-- SC DATA SCROLL 3G--<br />

Pivot to 5 th idler<br />

distance 000.00 IN<br />

ENTER<br />

If English Default: 0.00 in<br />

or Mixed: Min: 0.00 in<br />

Max: 100.00 in<br />

If Metric Default: 0 mm<br />

Min: 0 mm<br />

Max: 2500mm<br />

• Only if # of weigh idlers = 6:<br />

-- SC DATA SCROLL 3H--<br />

Pivot to 6 th idler<br />

distance 000.00 IN<br />

ENTER<br />

If English Default: 0.00 in<br />

or Mixed: Min: 0.00 in<br />

Max: 100.00 in<br />

If Metric Default: 0 mm<br />

Min: 0 mm<br />

Max: 2500mm<br />

Note: All measurements must be (within 0.032 inch or 1 mm) recorded in<br />

Section 2.5.1. Enter the distance with the numeric keys and press ENTER.<br />