Operation 1.4 Micro-Tech 3101 Standard Features The Model 3101 Integrator has many hardware and software features necessary for continuous weighting and outputting totalized weight and rate information. The main features are listed below. Other features are listed in specific sections of this manual. • Menu driven scroll entries on a four line display • Five LED status indicators • Visible and electrical outputs representing rate or load of the material movement • Visible and electrical output representing total amount of material that has passed the weighbridge • Audit trail (option) • Automatic zero and span calibration • Auto zero tracking • Several software options that may be turned on by keyboard entry or by installing optional plug-in PC boards • Optically coupled digital inputs and outputs • Alarms and failure detection • Communication standards: RS232C, RS485 networking multidrop, 20 mA current loop passive • Allen-Bradley DF1, Modbus RTU Figure 1-1: Micro-Tech 3101 Field Mount Integrator 1-2 Installation Thermo Fisher Scientific REC 4175 Rev B
Figure 1-2: Micro-Tech 3101 Panel Mount Integrator 1.5 Configuration Thermo Fisher Scientific Installation REC 4175 Rev B Installation The standard configuration of the Integrator includes the following: • Single channel loadcell input to a max of 6 loadcells • Single current output • 5 programmable digital inputs • 4 programmable outputs • 1 fault output • Serial communications • Solid state output • 3 circuit board expansion slots that can accommodate the following boards if needed. 1. Single channel current output board 2. Dual channel current output, analog input board (2 analog in and 2 analog out. 3. 16 digital inputs/4 digital outputs 4. 4 digital inputs/16 digital outputs 5. Serial communication board 6. Allen-Bradley remote I/O 7. Profibus-DP board 8. DeviceNet 1-3
- Page 1 and 2: Micro-Tech 3000 Model 3101 Integrat
- Page 3 and 4: ©2004Thermo Fisher Scientific. All
- Page 5 and 6: Thermo Scientific Warranty The sell
- Page 7 and 8: Contents Contents..................
- Page 9 and 10: About this Manual 2.9.1 Idler Spaci
- Page 11 and 12: About this Manual A.3.3.8 Ending an
- Page 13 and 14: About this Manual A.11.2. Define Lo
- Page 15 and 16: List of Figures Figure 1-1: Micro-T
- Page 17 and 18: List of Tables Table 1-1: Symbol Id
- Page 19 and 20: About this Manual This manual provi
- Page 21 and 22: General Precaution Thermo Fisher Sc
- Page 23: Chapter 1 Introduction This instruc
- Page 27 and 28: Thermo Fisher Scientific Installati
- Page 29 and 30: Thermo Fisher Scientific Installati
- Page 31 and 32: Maximum Non-Destructive Input Volta
- Page 33 and 34: Chapter 2 Installation 2.1 Safety P
- Page 35 and 36: 2.2 Incoming Power WARNING THIS EQU
- Page 37 and 38: Thermo Fisher Scientific Operation
- Page 39 and 40: Thermo Fisher Scientific Operation
- Page 41 and 42: Figure 2-6: Micro-Tech Motherboard
- Page 43 and 44: OP 13 OP 11 OP 10 OP 5 Table 2-3: L
- Page 45 and 46: Table 2-7: Relay Output Board Integ
- Page 47 and 48: Table 2-11: Motherboard Wiring Conf
- Page 49 and 50: Figure 2-8: Belt Scale Weighbridge
- Page 51 and 52: Thermo Fisher Scientific Operation
- Page 53 and 54: Thermo Fisher Scientific Operation
- Page 55 and 56: Figure 2-17: Measure of Incline A90
- Page 57 and 58: Press key under HELP for more infor
- Page 59 and 60: Thermo Fisher Scientific Operation
- Page 61 and 62: 2.8 Selecting the Weighbridge Model
- Page 63 and 64: -- SC DATA SCROLL 3C-- Pivot to 1 s
- Page 65 and 66: Thermo Fisher Scientific Operation
- Page 67 and 68: 2.9 Defining Dimensional Parameters
- Page 69 and 70: Default: 350 Ohms Min: 10 Ohms Max:
- Page 71 and 72: Thermo Fisher Scientific Operation
- Page 73 and 74: Thermo Fisher Scientific Operation
Figure 1-2: Micro-Tech 3101 Panel Mount Integrator<br />
1.5 Configuration<br />
<strong>Thermo</strong> Fisher Scientific Installation<br />
REC 4175 Rev B<br />
Installation<br />
The standard configuration of the Integrator includes the following:<br />
• Single channel loadcell input to a max of 6 loadcells<br />
• Single current output<br />
• 5 programmable digital inputs<br />
• 4 programmable outputs<br />
• 1 fault output<br />
• Serial communications<br />
• Solid state output<br />
• 3 circuit board expansion slots that can accommodate the following boards<br />
if needed.<br />
1. Single channel current output board<br />
2. Dual channel current output, analog input board (2 analog in and 2<br />
analog out.<br />
3. 16 digital inputs/4 digital outputs<br />
4. 4 digital inputs/16 digital outputs<br />
5. Serial communication board<br />
6. Allen-Bradley remote I/O<br />
7. Profibus-DP board<br />
8. DeviceNet<br />
1-3