About this Manual xvi WARNING KEEP HANDS AND CLOTHING AWAY FROM ALL MOVING OR ROTATING PARTS. WARNING DO NOT PLACE OR STORE OBJECTS OF ANY KIND ON THE MACHINE. WARNING THIS MACHINE SHOULD NOT BE OPERATED AT MORE THAN THE PRODUCTION RATE STATED ON YOUR EQUIPMENT SPECIFICATION SHEET OR USED IN APPLICATIONS OTHER THAN THOSE STATED IN THE ORIGINAL ORDER. Introduction Thermo Fisher Scientific REC 4175 Rev B

Chapter 1 Introduction This instruction manual contains information on the installation, operation, calibration, and maintenance of the Micro-Tech 3000 Model 3101 Field Mount and Panel Mount Integrator. 1.1 Unpacking and Inspection 1.2 Storage 1.3 Application The Micro-Tech 3101 Integrator has been properly packaged for shipment and storage, when necessary. Refer to the appropriate manual in the appendix section for unpacking procedures for optional equipment. Inspect all packages for damage before opening; sometimes the carrier may be responsible for shipping damage. Refer to the appropriate manual in the appendix for inspection procedures for optional equipment. The Micro-Tech 3101 Integrator can be safely stored, with cover, latches secured and hole plugs installed, between -40° to +158° F (-40° to +70° C). The units should be protected against moisture. • The Micro-Tech 3101 Filed Mount Integrator (Figure 1-1) or Panel Mount Integrator (Figure 1-2) is a microcomputer driven instrument used for deriving rate and quantity of flowing material from signals representing the weight of a segment of moving material and its velocity. By processing, these two input signals, the Integrator delivers visible and electrical output representing the rate of material movement and visible and electrical output representing total amount of material, which has passed the weighbridge. For remote indicating, four options are available: Remote Totalization Remote flow rate, belt loading or belt speed Communications Field Bus • The Integrator has provisions for 5 programmable logical inputs, 4 programmable outputs, and 1 fault output. • Optional I/O boards can be added. • Many automatic and check functions are available to the operator for calibration and maintenance. Thermo Fisher Scientific Installation 1-1

Chapter 1<br />

Introduction<br />

This instruction manual contains information on the installation, operation,<br />

calibration, and maintenance of the Micro-Tech 3000 Model 3101 Field<br />

Mount and Panel Mount Integrator.<br />

1.1 Unpacking and Inspection<br />

1.2 Storage<br />

1.3 Application<br />

The Micro-Tech 3101 Integrator has been properly packaged for shipment and<br />

storage, when necessary. Refer to the appropriate manual in the appendix<br />

section for unpacking procedures for optional equipment.<br />

Inspect all packages for damage before opening; sometimes the carrier may be<br />

responsible for shipping damage. Refer to the appropriate manual in the<br />

appendix for inspection procedures for optional equipment.<br />

The Micro-Tech 3101 Integrator can be safely stored, with cover, latches<br />

secured and hole plugs installed, between -40° to +158° F (-40° to +70° C). The<br />

units should be protected against moisture.<br />

• The Micro-Tech 3101 Filed Mount Integrator (Figure 1-1) or Panel Mount<br />

Integrator (Figure 1-2) is a microcomputer driven instrument used for<br />

deriving rate and quantity of flowing material from signals representing the<br />

weight of a segment of moving material and its velocity.<br />

By processing, these two input signals, the Integrator delivers visible and<br />

electrical output representing the rate of material movement and visible and<br />

electrical output representing total amount of material, which has passed the<br />

weighbridge.<br />

For remote indicating, four options are available:<br />

Remote Totalization<br />

Remote flow rate, belt loading or belt speed<br />

Communications<br />

Field Bus<br />

• The Integrator has provisions for 5 programmable logical inputs, 4<br />

programmable outputs, and 1 fault output.<br />

• Optional I/O boards can be added.<br />

• Many automatic and check functions are available to the operator for<br />

calibration and maintenance.<br />

<strong>Thermo</strong> Fisher Scientific Installation 1-1