About this Manual xvi WARNING KEEP HANDS AND CLOTHING AWAY FROM ALL MOVING OR ROTATING PARTS. WARNING DO NOT PLACE OR STORE OBJECTS OF ANY KIND ON THE MACHINE. WARNING THIS MACHINE SHOULD NOT BE OPERATED AT MORE THAN THE PRODUCTION RATE STATED ON YOUR EQUIPMENT SPECIFICATION SHEET OR USED IN APPLICATIONS OTHER THAN THOSE STATED IN THE ORIGINAL ORDER. Introduction Thermo Fisher Scientific REC 4175 Rev B
Chapter 1 Introduction This instruction manual contains information on the installation, operation, calibration, and maintenance of the Micro-Tech 3000 Model 3101 Field Mount and Panel Mount Integrator. 1.1 Unpacking and Inspection 1.2 Storage 1.3 Application The Micro-Tech 3101 Integrator has been properly packaged for shipment and storage, when necessary. Refer to the appropriate manual in the appendix section for unpacking procedures for optional equipment. Inspect all packages for damage before opening; sometimes the carrier may be responsible for shipping damage. Refer to the appropriate manual in the appendix for inspection procedures for optional equipment. The Micro-Tech 3101 Integrator can be safely stored, with cover, latches secured and hole plugs installed, between -40° to +158° F (-40° to +70° C). The units should be protected against moisture. • The Micro-Tech 3101 Filed Mount Integrator (Figure 1-1) or Panel Mount Integrator (Figure 1-2) is a microcomputer driven instrument used for deriving rate and quantity of flowing material from signals representing the weight of a segment of moving material and its velocity. By processing, these two input signals, the Integrator delivers visible and electrical output representing the rate of material movement and visible and electrical output representing total amount of material, which has passed the weighbridge. For remote indicating, four options are available: Remote Totalization Remote flow rate, belt loading or belt speed Communications Field Bus • The Integrator has provisions for 5 programmable logical inputs, 4 programmable outputs, and 1 fault output. • Optional I/O boards can be added. • Many automatic and check functions are available to the operator for calibration and maintenance. Thermo Fisher Scientific Installation 1-1
- Page 1 and 2: Micro-Tech 3000 Model 3101 Integrat
- Page 3 and 4: ©2004Thermo Fisher Scientific. All
- Page 5 and 6: Thermo Scientific Warranty The sell
- Page 7 and 8: Contents Contents..................
- Page 9 and 10: About this Manual 2.9.1 Idler Spaci
- Page 11 and 12: About this Manual A.3.3.8 Ending an
- Page 13 and 14: About this Manual A.11.2. Define Lo
- Page 15 and 16: List of Figures Figure 1-1: Micro-T
- Page 17 and 18: List of Tables Table 1-1: Symbol Id
- Page 19 and 20: About this Manual This manual provi
- Page 21: General Precaution Thermo Fisher Sc
- Page 25 and 26: Figure 1-2: Micro-Tech 3101 Panel M
- Page 27 and 28: Thermo Fisher Scientific Installati
- Page 29 and 30: Thermo Fisher Scientific Installati
- Page 31 and 32: Maximum Non-Destructive Input Volta
- Page 33 and 34: Chapter 2 Installation 2.1 Safety P
- Page 35 and 36: 2.2 Incoming Power WARNING THIS EQU
- Page 37 and 38: Thermo Fisher Scientific Operation
- Page 39 and 40: Thermo Fisher Scientific Operation
- Page 41 and 42: Figure 2-6: Micro-Tech Motherboard
- Page 43 and 44: OP 13 OP 11 OP 10 OP 5 Table 2-3: L
- Page 45 and 46: Table 2-7: Relay Output Board Integ
- Page 47 and 48: Table 2-11: Motherboard Wiring Conf
- Page 49 and 50: Figure 2-8: Belt Scale Weighbridge
- Page 51 and 52: Thermo Fisher Scientific Operation
- Page 53 and 54: Thermo Fisher Scientific Operation
- Page 55 and 56: Figure 2-17: Measure of Incline A90
- Page 57 and 58: Press key under HELP for more infor
- Page 59 and 60: Thermo Fisher Scientific Operation
- Page 61 and 62: 2.8 Selecting the Weighbridge Model
- Page 63 and 64: -- SC DATA SCROLL 3C-- Pivot to 1 s
- Page 65 and 66: Thermo Fisher Scientific Operation
- Page 67 and 68: 2.9 Defining Dimensional Parameters
- Page 69 and 70: Default: 350 Ohms Min: 10 Ohms Max:
- Page 71 and 72: Thermo Fisher Scientific Operation
Chapter 1<br />
Introduction<br />
This instruction manual contains information on the installation, operation,<br />
calibration, and maintenance of the Micro-Tech 3000 Model 3101 Field<br />
Mount and Panel Mount Integrator.<br />
1.1 Unpacking and Inspection<br />
1.2 Storage<br />
1.3 Application<br />
The Micro-Tech 3101 Integrator has been properly packaged for shipment and<br />
storage, when necessary. Refer to the appropriate manual in the appendix<br />
section for unpacking procedures for optional equipment.<br />
Inspect all packages for damage before opening; sometimes the carrier may be<br />
responsible for shipping damage. Refer to the appropriate manual in the<br />
appendix for inspection procedures for optional equipment.<br />
The Micro-Tech 3101 Integrator can be safely stored, with cover, latches<br />
secured and hole plugs installed, between -40° to +158° F (-40° to +70° C). The<br />
units should be protected against moisture.<br />
• The Micro-Tech 3101 Filed Mount Integrator (Figure 1-1) or Panel Mount<br />
Integrator (Figure 1-2) is a microcomputer driven instrument used for<br />
deriving rate and quantity of flowing material from signals representing the<br />
weight of a segment of moving material and its velocity.<br />
By processing, these two input signals, the Integrator delivers visible and<br />
electrical output representing the rate of material movement and visible and<br />
electrical output representing total amount of material, which has passed the<br />
weighbridge.<br />
For remote indicating, four options are available:<br />
Remote Totalization<br />
Remote flow rate, belt loading or belt speed<br />
Communications<br />
Field Bus<br />
• The Integrator has provisions for 5 programmable logical inputs, 4<br />
programmable outputs, and 1 fault output.<br />
• Optional I/O boards can be added.<br />
• Many automatic and check functions are available to the operator for<br />
calibration and maintenance.<br />
<strong>Thermo</strong> Fisher Scientific Installation 1-1