Appendix B<br />
Weighbridge Physical Parameters<br />
This appendix contains a listing of all weighbridges manufactured by <strong>Thermo</strong> Scientific.<br />
Each weighbridge is assigned a code number to be entered during initial programming of the<br />
Integrator. This code number defines the selected weighbridge’s default parameters and<br />
enables the Integrator to calculate span calibration constants (Cal-Con) for simulated<br />
calibration modes selected.<br />
Pressing the DETAIL soft key in SCALE DATA SCROLL 3 allows you to alter the<br />
physical parameters of the weighbridge. Scroll down to the desired parameter and enter in<br />
the correct factor, Cal-Con’s are calculated.<br />
Weighbridges not manufactured by <strong>Thermo</strong> Scientific can be defined by entering code<br />
number 0 and pressing DETAIL in SCALE DATA SCROLL 3. Scroll down and enter the<br />
weighbridge parameters in scroll positions 3A through 8F.<br />
Physical parameters and typical scale models are listed in Appendix Table B-1.<br />
Appendix Table B-1: Weighbridge Physical Parameters<br />
SCALE DATA<br />
SCROLL POSITIONS<br />
PARAMETER<br />
3<br />
3A<br />
3B<br />
3C<br />
3D<br />
3E<br />
3F<br />
3G<br />
3H<br />
3I<br />
3L<br />
3M<br />
3N<br />
3O<br />
4<br />
5<br />
6<br />
7<br />
8A<br />
8B<br />
8C<br />
8D<br />
8E<br />
8F<br />
Belt Scale Code #<br />
(LA) Pivot to Load Cell Distance<br />
(IDL) No. of Weigh Idlers<br />
(LB1) Pivot to 1st Idler Distance<br />
(LB2) Pivot to 2nd Idler Distance<br />
(LB3) Pivot to 3rd Idler Distance<br />
(LB4) Pivot to 4th Idler Distance<br />
(LB5) Pivot to 5th Idler Distance<br />
(LB6) Pivot to 6th Idler Distance<br />
(LE) Pivot to Test Weight Height<br />
(LC) Pivot to Test Weight Length<br />
(LF) Pivot to Carriage Height<br />
(LG) Carry Roll to Carriage Height<br />
No. of Load Cells<br />
(LD) Idler Spacing<br />
Conveyor's Angle Degrees<br />
Load Cell Capacity<br />
Load Cell Sensitivity mV/V<br />
Load Cell No.1 Resistance ohms<br />
Load Cell No.2 Resistance ohms<br />
Load Cell No.3 Resistance ohms<br />
Load Cell No.4 Resistance ohms<br />
Load Cell No.5 Resistance ohms<br />
Load Cell No.6 Resistance ohms<br />
<strong>Thermo</strong> Fisher Scientifc Linearization<br />
REC 4175 Rev B<br />