Menus A.12.4. Define Print Format By selecting YES in the following screen, the system is instructed to print one line each time a new alarm condition occurs. The alarm is printed as follows: xx-xx-xxxx yy:yyz kkkkkkkkkkkkkkkkkkkk Where: xx-xx-xxxx Day, Month, Year, printed according to the local format as defined in Main Menu 2 - Display Scroll, Section 4.2 of this Appendix. yy:yyz Hour, Minutes, am/pm printed according to the local format as defined in Main Menu 2 - Display Scroll, Section 4.3 of this Appendix. kkkkkkkkkkkkkkkkkkkk For example: 01-22-1998 8:14a Clock Fail Alarm message, same message appearing on the screen - PRINTER SCROLL 7 - Print alarms > No < CHOICE ENTER Default: NO Selections: YES, NO Password: Operator A-72 Weighbridge Physical Parameters Thermo Fisher Scientific REC 4175 Rev B
Menus There are three ways for defining the printing format. The first two are predefined formats, which are as follows: Appendix Table A-9: Predefined Print Format 1 DEFAULT 1 TOTALS REPORT DATE: 01-22-1998 TIME: 8:12a MASTER TOTAL: 0.00 Tons RESET TOTAL: 0.00 Tons OPERATOR TOTAL: 0.00 Tons RATE: 0.00 Tph Appendix Table A-10: Predefined Print Format 2 DEFAULT 2 DATE: 01-22-1998 TIME: 8:12a MASTER START TOTAL: 0.00 Tons MASTER STOP TOTAL: 0.00 Tons QUANTITY: 0.00 Tons Thermo Fisher Scientific Weighbridge Physical Parameters A-73 REC 4175 Rev B
- Page 155 and 156: Menus -- SC DATA SCROLL 3 -- Belt s
- Page 157 and 158: Menus Only if # of weigh idlers ≥
- Page 159 and 160: Menus Carry Roll to Carriage Height
- Page 161 and 162: Menus A.6.6.3 Load Cell Resistance
- Page 163 and 164: Menus A.7.1.1 Defining the R-Cal Pa
- Page 165 and 166: Menus The scroll displays the date
- Page 167 and 168: Menus When START is pressed, the sy
- Page 169 and 170: Menus When test duration is finishe
- Page 171 and 172: Menus The following scrolls are onl
- Page 173 and 174: Menus A SERVICE password is require
- Page 175 and 176: Menus Default: 3497 Min: 0 Max: 300
- Page 177 and 178: Menus A.9.5. Display Software Versi
- Page 179 and 180: Menus A.9.8. Force Cold Start This
- Page 181 and 182: Menus WARNING IF THE USER PRESSES C
- Page 183 and 184: Menus A.9.18. Test BCD Output Board
- Page 185 and 186: Menus Default: (1st) 0 sec, (2nd) 0
- Page 187 and 188: Menus A.10.4. Setup Inclination Com
- Page 189 and 190: Menus Appendix Table A-4: Mother Bo
- Page 191 and 192: Menus Appendix Table A-6: Available
- Page 193 and 194: Menus WARNING CHANGING THE DEFINITI
- Page 195 and 196: Menus - I/O DEF SCROLL 9A- BCD inpu
- Page 197 and 198: Menus A.11.1. Define Rate Alarm Use
- Page 199 and 200: Menus - ALARM SCROLL 3A - Low speed
- Page 201 and 202: Menus - COMM. A SCROLL 4 - Wordleng
- Page 203 and 204: Menus Default: 8 BITS Selections: 7
- Page 205: Menus A form feed character can be
- Page 209 and 210: Menus Once you have defined the str
- Page 211 and 212: Menus The Reset Total: - PRINTER SC
- Page 213 and 214: Menus A.12.5. The PRINT Key The PRI
- Page 215 and 216: Menus A.13. MAIN MENU 6 Main Menu 6
- Page 217 and 218: Appendix B Weighbridge Physical Par
- Page 219 and 220: Digital Input/Output Appendix Figur
- Page 221 and 222: Digital Input/Output # MODEL BELT W
- Page 223 and 224: Digital Input/Output # MODEL BELT W
- Page 225 and 226: Appendix C Linearization Request RE
- Page 227 and 228: Appendix D Digital Input/Output The
- Page 229 and 230: Digital Input/Output D.2. Digital I
- Page 231 and 232: Digital Input/Output Thermo Fisher
- Page 233 and 234: Digital Input/Output Appendix Figur
- Page 235 and 236: Digital Input/Output D.4. Analog I/
- Page 237 and 238: Digital Input/Output Appendix Figur
- Page 239 and 240: Digital Input/Output Appendix Figur
- Page 241 and 242: Appendix E Multi-Point Calibration
- Page 243 and 244: Multi-Point Calibration E.2.2. Digi
- Page 245 and 246: Appendix F Minor Calibration Notes:
- Page 247 and 248: Appendix G Optional Documentation T
- Page 249 and 250: Appendix H Engineering Drawings Fi
Menus<br />
There are three ways for defining the printing format. The first two are<br />
predefined formats, which are as follows:<br />
Appendix Table A-9: Predefined Print Format 1<br />
DEFAULT 1<br />
TOTALS REPORT<br />
DATE: 01-22-1998<br />
TIME: 8:12a<br />
MASTER TOTAL: 0.00 Tons<br />
RESET TOTAL: 0.00 Tons<br />
OPERATOR TOTAL: 0.00 Tons<br />
RATE: 0.00 Tph<br />
Appendix Table A-10: Predefined Print Format 2<br />
DEFAULT 2<br />
DATE: 01-22-1998<br />
TIME: 8:12a<br />
MASTER START TOTAL: 0.00 Tons<br />
MASTER STOP TOTAL: 0.00 Tons<br />
QUANTITY: 0.00 Tons<br />
<strong>Thermo</strong> Fisher Scientific Weighbridge Physical Parameters A-73<br />
REC 4175 Rev B