A.11.1. Define Rate Alarm<br />

Use the CHOICE key to turn on or off the rate alarm. Confirm with ENTER.<br />

Default: NO<br />

Selections: YES, NO<br />

If the selection in the previous screen was YES, enter the low and high set points<br />

for the alarm. Also, enter the desired delay time before the alarm is monitored.<br />

The UNITS key allows the user to specify the set points in engineering units.<br />

The % key selects set points in percent. The SET/DLY switches between the set<br />

point and the delay time.<br />

Default: 10% 10 sec<br />

Min: 0 % 0 sec<br />

Max: 105 % 90 sec<br />

Default: 10 % 10 sec<br />

Min: 0 % 0 sec<br />

Max: 150 % 90 sec<br />

A.11.2. Define Load Alarm<br />

Use the CHOICE key to turn on or off the belt loading alarm. Confirm with<br />

ENTER.<br />

Default: NO<br />

Selections: YES, NO<br />

- ALARM SCROLL 1 -<br />

Rate alarm<br />

YES NO<br />

- ALARM SCROLL 1A -<br />

Low rate set<br />

10 % 105 sec<br />

ENTER SET/DELAY UNITS/%<br />

- ALARM SCROLL 1B -<br />

High rate set<br />

100 % 10 sec<br />

ENTER SET/DELAY UNITS/%<br />

- ALARM SCROLL 2 -<br />

Load Alarm<br />

> NO <<br />

CHOICE ENTER<br />