Thermo Ramsey - Hoferick Engineering GmbH

Thermo Ramsey - Hoferick Engineering GmbH Thermo Ramsey - Hoferick Engineering GmbH

25.04.2013 Views

Menus A.10.8. Define BCD Output Data If an optional load out board is installed, the user can select the related variable. - I/O DEF SCROLL 8 - BCD Output variable > Rate < CHOICES ENTER Default: OFF Selections: OFF, RATE, LOAD, SPEED If a selection other than OFF is made, the following screens allow the user to define the polarity and the parity check of the BCD output. The polarity selection reverses the signals from NO to NC and vice versa. If a parity criterion is selected, the most significant bit of the BCD output is used for parity check. - I/O DEF SCROLL 8A- BCD Output polarity > Positive < CHOICES ENTER Default: NEGATIVE Selections: POSITIVE, NEGATIVE - I/O DEF SCROLL 8B- BCD Output parity > Yes < CHOICES ENTER Default: NO Selections: NO, YES A.10.9. Define BCD Input Data If an optional load out input board is installed, the following screens allow the user to define the related variable and the polarity of the signals. I/O DEF SCROLL 9 - BCD Input variable > Load out setpoint Default: OFF Selections: OFF, BATCH PRE-ACT, BATCH SETPOINT Only if BCD input is not set to OFF: Password: Service Password: Service Password: Service Password: Service A-60 Weighbridge Physical Parameters Thermo Fisher Scientific REC 4175 Rev B

Menus - I/O DEF SCROLL 9A- BCD input polarity > Positive < CHOICES ENTER Default: OFF Selections: OFF, BATCH PRE-ACT, BATCH SETPOINT Only if BCD input is not set to OFF: - I/O DEF SCROLL 9A- BCD input polarity > Positive < CHOICES ENTER Default: NEGATIVE Selections: NEGATIVE, POSITIVE A.10.10. Clip Detector Option The clip detector option reduces flow rate errors on light loaded belts caused by conveyor belt weight variances. Turning on Auto Zero Tracking in the Cal Data Scroll enables the clip detector. The clip detector is normally a proximity switch that senses a metal target attached to the belt. In manual mode, the clip detector freezes the flow rate when the clip is detected and maintains it frozen for the programmed length. Totalization is not affected. In automatic, the Integrator automatically detects tare variations and compensates for them. If the clip detector is assigned to one digital I/O input, the following screens appear. - I/O DEF SCROLL 10- Clip detector mode MANUAL CHOICE ENTER Password: Service Password: Service Password: Service Default: MANUAL Choices: MANUAL, AUTO In the MANUAL mode, the user must enter the length of belt, which is affected, by the belt splice. The system freezes the belt loading when the clip is detected and maintains it frozen until the specified belt length has passed. Thermo Fisher Scientific Weighbridge Physical Parameters A-61 REC 4175 Rev B

Menus<br />

A.10.8. Define BCD Output Data<br />

If an optional load out board is installed, the user can select the related variable.<br />

- I/O DEF SCROLL 8 -<br />

BCD Output variable<br />

> Rate <<br />

CHOICES ENTER<br />

Default: OFF<br />

Selections: OFF, RATE, LOAD, SPEED<br />

If a selection other than OFF is made, the following screens allow the user to<br />

define the polarity and the parity check of the BCD output. The polarity<br />

selection reverses the signals from NO to NC and vice versa. If a parity<br />

criterion is selected, the most significant bit of the BCD output is used for parity<br />

check.<br />

- I/O DEF SCROLL 8A-<br />

BCD Output polarity<br />

> Positive <<br />

CHOICES ENTER<br />

Default: NEGATIVE<br />

Selections: POSITIVE, NEGATIVE<br />

- I/O DEF SCROLL 8B-<br />

BCD Output parity<br />

> Yes <<br />

CHOICES ENTER<br />

Default: NO<br />

Selections: NO, YES<br />

A.10.9. Define BCD Input Data<br />

If an optional load out input board is installed, the following screens allow the<br />

user to define the related variable and the polarity of the signals.<br />

I/O DEF SCROLL 9 -<br />

BCD Input variable<br />

> Load out setpoint<br />

Default: OFF<br />

Selections: OFF, BATCH PRE-ACT, BATCH SETPOINT<br />

Only if BCD input is not set to OFF:<br />

Password: Service<br />

Password: Service<br />

Password: Service<br />

Password: Service<br />

A-60 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B