Menus<br />
WARNING<br />
CHANGING THE DEFINITION OF THE DIGITAL INPUTS<br />
MAY CAUSE MACHINERY TO START. AFTER THE USER<br />
TRIES TO CHANGE A DEFINITION, THE FOLLOWING<br />
MESSAGE IS DISPLAYED.<br />
WARNING<br />
EQUIPMENT MAY START<br />
CONTINUE ABORT<br />
IF THE USER PRESSES CONTINUE, BE AWARE THE<br />
ACTION MAY CAUSE DAMAGE OR INJURY. IF THE<br />
USER PRESSES ABORT, THE SYSTEM WILL RETURN<br />
TO THE PREVIOUS SCROLL.<br />
A.10.6. Define Digital Outputs<br />
Digital outputs can be programmed. The following screen shows one logical<br />
function per time, and allows the user to assign it to a physical output. The<br />
NEXT key scrolls between the logical functions. The NC/NO key selects the<br />
Normally Open (NO) or Normally Closed (NC) status of the output. Normally<br />
Open means the output is not energized in normal conditions. To program a<br />
function, scroll with NEXT until the function is displayed, then enter the<br />
number of the physical output and confirm with ENTER; finally scroll with<br />
NC/NO until the desired mode is displayed. By assigning a function to 0, the<br />
function is disabled.<br />
- I/O DEF SCROLL 5 -<br />
Dig. Output def.<br />
Alarm: 0 NC<br />
ENTER NC/NO NEXT<br />
The following table shows the available logical selections that can be assigned<br />
to any available physical output. Typical field wiring drawings and customer<br />
specific field wiring drawings show Ready defaulted to #1 NC, Alarm defaulted<br />
to #2 NC and Totalizer (remote counter) defaulted to #3 NO. Default selections<br />
can be reassigned to any physical output if desired.<br />
Logical selections should not be reassigned after the physical outputs have been<br />
wired.<br />
CAUTION<br />
LOGICAL SELECTIONS RETURN TO THE DEFAULT IF THE<br />
INTEGRATOR IS COLD STARTED.<br />
Password: Service<br />
A-56 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />
REC 4175 Rev B