Menus<br />

Appendix Table A-4: Mother Board Inputs<br />

PHYSICAL<br />

INPUT<br />

NUMBER<br />

ASSIGNED<br />

FUNCTION<br />

1 BELT SPEED INPUT TB1-2 TB1-3<br />

2 TB2-12 TB2-13<br />

3 TB2-14 TB2-15<br />

4 TB2-16 TB2-17<br />

5 TB2-18 TB2-19<br />

Additional assignable logical inputs from the above table can be selected by<br />

adding optional I/O boards. Available options are 4in/16out, 16in/4out or<br />

20in/20out by adding both boards.<br />

Appendix Table A-5: Digital Input/Output Board Inputs<br />

INSTALLED OPTIONS<br />

PHYSICAL<br />

INPUT<br />

NUMBER<br />

ASSIGNED<br />

FUNCTION<br />

4IN/16OUT<br />

ONLY<br />

16IN/4OUT<br />

ONLY<br />

4IN/16OUT<br />

AND<br />

16IN/4OUT<br />

6 J15 - 2 J16 - 17 J15 - 2<br />

7 J15 - 15 J16 - 5 J15 - 15<br />

8 J15 - 3 J16 - 18 J15 - 3<br />

9 J15 - 16 J16 - 6 J15 - 16<br />

10 J16 - 19 J16 - 17<br />

11 J16 - 7 J16 - 5<br />

12 J16 - 20 J16 - 18<br />

13 J16 - 8 J16 - 6<br />

14 J16 - 21 J16 - 19<br />

15 J16 - 9 J16 - 7<br />

16 J16 - 22 J16 - 20<br />

17 J16 - 10 J16 - 8<br />

18 J16 - 23 J16 - 21<br />

19 J16 - 11 J16 - 9<br />

20 J16 - 24 J16 - 22<br />

21 J16 - 12 J16 - 10<br />

22 J16 - 23<br />

23 J16 - 11<br />

24 J16 - 24<br />

25 J16 - 12<br />

<strong>Thermo</strong> Fisher Scientific Weighbridge Physical Parameters A-55<br />

REC 4175 Rev B