Default: 3497<br />

Min: 0<br />

Max: 30000<br />

A.9.3. Change Prescaler<br />

The prescaler is a number, which is used to divide the incoming frequency of the<br />

speed sensor(s) to achieve a usable input frequency of approximately 30 Hz.<br />

The prescaler is automatically calculated and should never be altered by the<br />

user. However, a direct entry has been made possible for quick replacement of<br />

the Integrator.<br />

Default: 10<br />

Min: 1<br />

Max: 100<br />

If CALIB is pressed, the following screens appear.<br />

Default: 900<br />

Min: 1<br />

Max: 100000<br />

-DIAGNOST. SCROLL 2B<br />

Loadcell output span<br />

0000000<br />

ENTER<br />

-DIAGNOST. SCROLL 3-<br />

Prescale 00000<br />

00000.0 pls/min<br />

ENTER CALIB<br />

-DIAGNOST. SCROLL 3A<br />

Test duration total<br />

pulses 0000000<br />

ENTER<br />

-DIAGNOST. SCROLL 3B<br />

Test duration total<br />

length 00000.0 ft<br />

ENTER<br />

English/Mixed Metric<br />

Default: 200 feet Default: 200 m<br />

Min: 1 foot Min: 1 m<br />

Max: 100000 feet Max: 100000 m<br />

Password: Service<br />

Password: Service<br />

Password: Service<br />

Password: Service<br />

<strong>Thermo</strong> Fisher Scientific Weighbridge Physical Parameters A-41<br />