Menus<br />

A.6.6.3 Load Cell Resistance<br />

Load cell resistance is entered on this screen. The resistance for the load cell<br />

has been recorded on the System Data Sheet in the front of your belt scale<br />

manual. (It is also stamped on the load cell cable.) Enter the ohms for the load<br />

cell. The number of scrolls depends on the number of load cells specified in<br />

scroll 3O.<br />

-- SC DATA SCROLL 8X --<br />

Load cell #N res<br />

3.00 Ohms<br />

ENTER<br />

X = A, B, C, D, E, or F<br />

n = 1, 2, 3, 4, 5, or 6<br />

Default: 350 Ohms<br />

Min: 10 Ohms<br />

Max: 2000 Ohms<br />

Note: One screen displays for each load cell.<br />

A.6.7. Defining the Speed Input<br />

The speed input screen allows the operator to select the single speed sensor<br />

input (default value) or a simulated value using an internal timer.<br />

Simulation allows operation without a speed sensor. When simulated speed is<br />

selected, a conveyor running input is required (refer to the field wiring diagram).<br />

Note: If speed is selected as the third line display in the RUN screen, the line<br />

will be blank in RUN mode when simulated speed is selected.<br />

-- SC DATA SCROLL 9 --<br />

Speed input<br />

>single<<br />

CHOICE ENTER<br />

Default: SINGLE<br />

Choices: SINGLE, SIMULATED<br />