Menus<br />

A.6.5.2 Angle of Inclination<br />

Enter the angle of inclination. If an inclination meter is connected to the scale,<br />

after this preliminary set up has been completed, enable the automatic angle<br />

detection in I/O DEFINITION (MENU 4) and calibrate the angle meter.<br />

Default: 0.0<br />

Min: -25.00°<br />

Max: +25.00°<br />

A.6.6. Defining the Load Cell(s)<br />

A.6.6.1 Load Cell Capacity<br />

Enter the load cell capacity as it appears on the label placed on the load cell.<br />

English/Mixed Metric<br />

Default: 250.0 Lbs Default: 100 kg<br />

Min: 1 Lbs Min: 1 kg<br />

Max: 15000 Lbs Max: 5000 kg<br />

A.6.6.2 Load Cell Sensitivity<br />

The sensitivity was entered when the belt scale code was entered. If other (0)<br />

was selected, enter the load cell sensitivity in mV/V as marked on the label of<br />

the load cell. <strong>Thermo</strong> Scientific load cells are normally 2.000 or 3.000 mV/V.<br />

Default: 3.0 mV/V<br />

Min: 0.500 mV/V<br />

Max: 3.500 mV/V<br />

-- SC DATA SCROLL 5 --<br />

Conveyor’s angle<br />

0 0 Degrees<br />

ENTER +/-<br />

-- SC DATA SCROLL 6 --<br />

Load cell capacity<br />

250 Lbs<br />

ENTER<br />

-- SC DATA SCROLL 7 --<br />

Load cell sens.<br />

3.00 mV/V<br />

ENTER<br />

Password:<br />

Service<br />

Password:<br />

Service<br />

Password:<br />

Service<br />

A-26 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B