25.04.2013 Views

Thermo Ramsey - Hoferick Engineering GmbH

Thermo Ramsey - Hoferick Engineering GmbH

Thermo Ramsey - Hoferick Engineering GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Menus<br />

-- SC DATA SCROLL 3 --<br />

Belt scale code #<br />

>1<<br />

CHOICE DETAIL<br />

Default: 1<br />

Min: 0<br />

Max: 500<br />

Press ENTER to accept the displayed selection (refer Appendix B, <strong>Thermo</strong><br />

Scientific Weighbridge Physical Parameters.).<br />

Note: If the default is used, the scrolls from 3A to 3J are not displayed.<br />

Press DETAIL if you want to force the following scrolls to be displayed even if<br />

the default was chosen.<br />

• 3A – 30<br />

Enter 0 if you want to define the weighbridge not using the database. This<br />

should only be done for special weighbridges that are not part of the standard set<br />

of <strong>Thermo</strong> Scientific scales. Entering 0 forces the following menus to be<br />

displayed:<br />

A.6.4. Detailing the Mechanical Parameters of the Frame<br />

These menus only display if OTHER or DETAIL was selected in Section A.4.23.<br />

Pivot to Load Cell Distance (Parameter LA)<br />

The distance from the pivot to load cell should be measured to within 0.032 inch<br />

(1/32”) (1mm). Using the numeric keys enter the distance recorded in Section<br />

2.6.1.3.1 and press ENTER.<br />

For weighbridges, which do not have a pivot, enter zero (0).<br />

-- SC DATA SCROLL 3A --<br />

Pivot to load cell<br />

distance: IN<br />

ENTER<br />

English/Mixed Metric<br />

Default: 32 in Default: 1000 mm<br />

Min: 0.00 in Min: 0 mm<br />

Max: 150.00 in Max: 3800 mm<br />

<strong>Thermo</strong> Fisher Scientific Weighbridge Physical Parameters A-21<br />

REC 4175 Rev B