A.6. Scale Data<br />

Refer to Section 2.6 and Appendix B Weighbridge Physical Parameters.<br />

A.6.1. Scale Capacity<br />

Scale capacity is the maximum rate at which the scale is allowed to work. This<br />

entry also defines the default number of decimal places used for displaying rate.<br />

Use the NUMERIC keys for entering the number. Confirm with ENTER; scroll<br />

DOWN.<br />

-- SC DATA SCROLL 1 --<br />

Max. scale capacity<br />

500.0 TPH<br />

CHOICE ENTER<br />

Default: 500.0<br />

Min: 1<br />

Max: 200000<br />

A.6.2. Scale Divisions<br />

When the SCALE CAPACITY is entered, the number of decimal places is also<br />

defined. For example, the user enters 500.0; this sets the SCALE DIVISIONS<br />

parameter to 0.1.<br />

At the SCALE DIVISIONS menu, the displayed SCALE DIVISION<br />

corresponds to the just entered SCALE CAPACITY. The user can change the<br />

pre-set SCALE DIVISIONS by pressing CHOICES.<br />

-- SC DATA SCROLL 2 --<br />

Scale divisions<br />

>0.1<<br />

CHOICE ENTER<br />

Default: 0.1<br />

Choices: 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 0.01, 0.02, 0.05, 0.001, 0.002,<br />

0.005<br />

Make your choice and press ENTER to save the choice.<br />

A.6.3. Selecting the Weighbridge Model<br />

By entering the code number of your <strong>Thermo</strong> Scientific scale, the Integrator<br />

automatically calculates parameters of the system such as number of load cells<br />

and number of weigh idlers. (Refer to Appendix B for further information<br />

regarding specific weighbridges.)<br />

This menu items is also used for internal calibration calculations. The default<br />

model number is 1, which corresponds to belt scale model 10-20-1.<br />

A-20 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />