Thermo Ramsey - Hoferick Engineering GmbH
Thermo Ramsey - Hoferick Engineering GmbH
Thermo Ramsey - Hoferick Engineering GmbH
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Menus<br />
A.6. Scale Data<br />
Refer to Section 2.6 and Appendix B Weighbridge Physical Parameters.<br />
A.6.1. Scale Capacity<br />
Scale capacity is the maximum rate at which the scale is allowed to work. This<br />
entry also defines the default number of decimal places used for displaying rate.<br />
Use the NUMERIC keys for entering the number. Confirm with ENTER; scroll<br />
DOWN.<br />
-- SC DATA SCROLL 1 --<br />
Max. scale capacity<br />
500.0 TPH<br />
CHOICE ENTER<br />
Default: 500.0<br />
Min: 1<br />
Max: 200000<br />
A.6.2. Scale Divisions<br />
When the SCALE CAPACITY is entered, the number of decimal places is also<br />
defined. For example, the user enters 500.0; this sets the SCALE DIVISIONS<br />
parameter to 0.1.<br />
At the SCALE DIVISIONS menu, the displayed SCALE DIVISION<br />
corresponds to the just entered SCALE CAPACITY. The user can change the<br />
pre-set SCALE DIVISIONS by pressing CHOICES.<br />
-- SC DATA SCROLL 2 --<br />
Scale divisions<br />
>0.1<<br />
CHOICE ENTER<br />
Default: 0.1<br />
Choices: 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 0.01, 0.02, 0.05, 0.001, 0.002,<br />
0.005<br />
Make your choice and press ENTER to save the choice.<br />
A.6.3. Selecting the Weighbridge Model<br />
By entering the code number of your <strong>Thermo</strong> Scientific scale, the Integrator<br />
automatically calculates parameters of the system such as number of load cells<br />
and number of weigh idlers. (Refer to Appendix B for further information<br />
regarding specific weighbridges.)<br />
This menu items is also used for internal calibration calculations. The default<br />
model number is 1, which corresponds to belt scale model 10-20-1.<br />
A-20 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />
REC 4175 Rev B