Menus<br />

A.3.7. Updating the Span Constant<br />

After the amount of material has been entered, the following screen displays:<br />

MAT’L CAL. COMPLETE<br />

Error 000.00 %<br />

change span?<br />

YES NO ADV<br />

Complete flashes<br />

YES – moves to the following screen<br />

ADV changes from Error % to Actual Difference of Total<br />

NO moves to the following screen:<br />

MAT’L CALIBRATION<br />

Add reference<br />

weight to totals?<br />

YES NO<br />

YES – the reference weight is added to the totals and the Integrator returns<br />

to MAIN MENU 1<br />

NO – returns to MAIN MENU 1<br />

A.3.8. Acquiring the Material Factors<br />

If yes was selected at the Updating the Span Constant screen, the following<br />

screen displays confirming the new span constant was installed.<br />

SPAN # CHANGED<br />

New span # 000000<br />

Old span # 000000<br />

RUN MENU FACTOR<br />

At this point, the scale is calibrated to the actual material test.<br />

RUN – returns to the RUN main menu<br />

MENU – returns to MAIN MENU 1<br />

FACTOR – Of the three simulated load calibration methods, only the ones that<br />

have been already used are shown. It is not possible to calculate a material<br />

factor if a simulated test was not run before the material test. The following<br />

screen displays:<br />

MAT’L CALIBRATION<br />

Automatic correction<br />

to Material Factors<br />

R-CAL WTS CHAIN<br />

If none of the three was performed, FACTOR is not displayed.<br />

A-14 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B