Menus<br />

A.3.3.6 Recording New Span<br />

The Integrator calculates the new span based on the result of the test performed<br />

with the simulated method.<br />

AUTO SPAN COMPLETE<br />

Error +/-00.00 %<br />

Change span?<br />

YES NO ADV<br />

Complete is flashing<br />

ADV – advances to Accumulated Weight, Cal Con, Material Factor, and back to<br />

Error %.<br />

YES – if the operator selects YES, the following screen displays:<br />

Note: If the Material Factor is invalid (never acquired before), it is not<br />

displayed.<br />

SPAN # CHANGED<br />

Old span #: 00000<br />

New span #: 00000<br />

RUN REPEAT ADV<br />

RUN – returns to the RUN main menu<br />

REPEAT – moves back to Section 3.10.3.1.4 and calibration restarts<br />

ADV – changes from Error % to Accumulated Weight, Calcon, Old Span,<br />

and Material Factor (if not invalid).<br />

NO – If the operator selects NO, the following screen displays:<br />

SPAN UNCHANGED<br />

Old span #: 00000<br />

New span #: 00000<br />

RUN REPEAT ADV<br />

RUN – returns to the RUN main menu<br />

REPEAT – moves back to Section 3.10.3.1.4 and calibration restarts.<br />

ADV – changes from Error % to Accumulated Weight, Calcon, Old Span,<br />

and Material Factor (if not invalid).<br />

Note: The Old Span and New Span are equal because no change has been made<br />

to the span.<br />

A-10 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B