Menus<br />

Hint: The percentage of error is related to full-scale capacity.<br />

ZERO # CHANGED<br />

New zero #00000<br />

Old zero #00000<br />

RUN MENU ADV<br />

ADV changes from OLD ZERO to RATE to ACCUMULATED WEIGHT<br />

and to ERROR %<br />

MENU repeats Auto Zero calibration.<br />

RUN returns to the RUN menu<br />

A.3.2. Manual Zero<br />

The Manual Zero procedure shows the zero constant and allows direct entry if<br />

known. Press ENTER to confirm the new number.<br />

-- MANUAL ZERO --<br />

Rate 000.0 Tph<br />

Zero #00000<br />

ENTER EXIT ADV<br />

Password: Operator<br />

Default: 40000<br />

Min: 0<br />

Max: 120000<br />

• ADV displays only if Auto Zero Tracking is enabled. The ZST function<br />

accurately tracks the zero of the scale by calculating an additional zero<br />

constant. The portion of zero due to AZT is not incorporated in the zero<br />

constant, but is shown separately.<br />

A-4 Weighbridge Physical Parameters <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B