Replacement Parts<br />

4.7.1 No Password Installed<br />

1. If there is no password installed, select MAIN MENU 3<br />

2. Press DIAG soft key and scroll down to the SRVICE PASSWORD screen.<br />

3. Type in a password (example: 123) and press ENTER<br />

4. Re-enter the password and press ENTER<br />

5. Select MAIN MENU 3<br />

6. Select PROT scroll, press PROT<br />

7. Press NONE<br />

8. Enter the password 7832500 and press ENTER. The protection level should<br />

be RAMSEY.<br />

9. Press TOTAL; scroll up or down if needed to reach the MASTER TOTAL<br />

screen.<br />

10. Press RESET and select YES to “Reset Master Total?”<br />

11. Select MAIN MENU 3. Press DIAG and scroll to SERVICE<br />

PASSWORD.<br />

12. Press ENTER twice, erasing the password installed in Step 3.<br />

13. Press RUN to return to normal operation.<br />

4.7.2 Active Password<br />

1. Select MAIN MENU 3<br />

2. Select PROT scroll, press PROT<br />

3. Press NONE<br />

4. Enter the password 7832500 and press ENTER. The protection level should<br />

be RAMSEY.<br />

5. Press TOTAL; scroll up or down if needed to reach the MASTER TOTAL<br />

screen.<br />

6. Press RESET and select YES to “Reset Master Total?”<br />

7. Select MAIN MENU 3<br />

8. Press PROT and choose the password level desired.<br />

4.8 Removing a Forgotten Password<br />

Use the following steps to remove a forgotten password from Integrator<br />

memory.<br />

1. Select MAIN MENU 3<br />

2. Select the PROTECT scroll and press PROT<br />

3. Press NONE<br />

4. Enter the password 7832500 and press ENTER. The protection level should<br />

be RAMSEY.<br />

5. Press NONE<br />

6. Select MAIN MENU 3<br />

7. Press DIAG and scroll to SERVICE PASSWORD<br />

<strong>Thermo</strong> Fisher Scientific Replacement Parts<br />