Maintenance<br />

3-22<br />

At this point, the scale is calibrated to the actual material test.<br />

Run: returns to the RUN main menu<br />

Menu: returns to MAIN MENU 1<br />

Factor: Of the three simulated load calibration methods, only the ones that<br />

have been already used are shown. It is not possible to calculate a material<br />

factor if a simulated test was not run before the material test. The following<br />

screen displays:<br />

MAT’L CALIBRATION<br />

Automatic correction<br />

to Material Factors<br />

R-CAL WTS CHAIN<br />

If none of the three was performed, FACTOR is not displayed.<br />

• If R-CAL, WEIGHTS, or CHAINS is pressed, the following screen displays:<br />

XXXX MAT’L FACTOR<br />

New factor 000.00 %<br />

Change factor?<br />

ADV YES NO<br />

ADV: advances to the Old Factor and again to the New Factor<br />

NO: select NO if the acquired material factor is not desired. This selection<br />

returns to Section 8<br />

Yes: select YES if this specific simulated method of calibration has already<br />

been used and the related material factor will be recorded. This selection<br />

advances to the next scroll.<br />

The system is able to execute accurate calibrations in the future with this<br />

simulated method. The following screen displays:<br />

XXXX MAT’L FACTOR<br />

Old factor 000.00 %<br />

New factor 000.00 %<br />

RUN MENU FACTOR<br />

XXXX = R-CAL,<br />

WEIGHTS, or CHAINS<br />

FACTOR: repeats for all simulated tests previously run.<br />

RUN OR MENU: if RUN or MENU is selected, the following screen displays:<br />

9. Adding the Reference Weight to Total<br />

MAT’L CALIBRATION<br />

Add reference<br />

weight to totals<br />

YES NO<br />

XXXX = R-CAL,<br />

WEIGHTS, or CHAINS<br />

Maintenance <strong>Thermo</strong> Fisher Scientific<br />

REC 4175 Rev B