<strong>Problems</strong> <strong>during</strong> <strong>the</strong> <strong>application</strong><br />

<strong>1.</strong>10 Discharges<br />

Detection Possible cause Remedy<br />

Spark formation Insufficiently conductive hose<br />

material<br />

Objects insufficiently grounded<br />

Electric shock to humans Insufficient grounding of manual gun<br />

Use hoses recommended by<br />

coating unit supplier<br />

Clean suspension hooks<br />

Remove paint from suspension<br />

gear regularly<br />

Grounding cable<br />

Observe cross section<br />

Use of metallic powder Use suitable gun attachment<br />

Wear conductive protective<br />

clothing (shoes)