TOLYLTRIAZOLE PROCEDURE 1. Press and hold ON button until colorimeter turns on. 2. Press ENTER to start. 3. Press ENTER to select Testing Menu. 4. Select ALL TESTS (or another sequence containing 97 T triazole from TESTING MENU. 5. Scroll to and select 97 T triazole from menu. 6. Rinse a tube (0290) with sample water. Fill to 10 mL with sample. 7. Insert the tube into chamber, close lid and select SCAN BLANK. 8. Remove the tube from colorimeter. Discard the sample. 9. Adjust the sample water temperature to between 20 and 25C if necessary. 10. Fill the graduated cylinder (0417) to the 25 mL line with sample water. Transfer to the Erlenmeyer Flask (2-2109). 11. Use the pH Test Paper (9259) to check the pH of the sample. If the pH is not between 4 and 6, add one drop of *Sulfuric Acid, 1.0N (6139). Swirl to mix. Continue adding *Sulfuric Acid, 1.0N (6139) one drop at a time, swirling to mix and checking the pH after each drop, until the pH is between 4 and 6. 12. Add 10 drops of NaK Tartrate (7841). 13. Use the 0.25 g spoon (0695) to add one measure of *Benzotriazole Reagent (3818). Swirl to mix until the powder has dissolved. 14. Replace the flask in the slot in the case. Insert the Penray Lamp (31041-1) into the flask. Plug in the Penray Power Source (31041-2) and turn the lamp on for exactly 5 minutes. Remove the lamp from the flask. Rinse and wipe the lamp dry. 15. Fill a test tube (0290) to the 10 mL line with the digested sample. Cap tube. 16. Insert tube into chamber, close lid and select SCAN SAMPLE. Record result in ppm Tolyltriazole. 17. Press OFF button to turn the colorimeter off or press EXIT button to exit to a previous menu or make another menu selection. NOTE: For best possible results, a reagent blank should be determined to account for any contribution to the test result by the reagent system. To determine the reagent blank, follow the above test procedure to scan a distilled or deionized water blank. Then follow the above procedure to perform the test on a distilled or deionized water sample. This test result is the reagent blank. Subtract the reagent blank from all subsequent test results of unknown samples. It is necessary to determine the reagent blank only when a new lot number of reagents is obtained. Benzotriazole/Tolyltriazole 4/4 Smart2 TEST PROCEDURES 7.06

BIGUANIDE COLORIMETRIC METHOD CODE 4044 QUANTITY CONTENTS CODE 2 X 60 mL Biguanide Indicator 3994-H 1 Pipet, plastic, 1.0 mL 0354 Biguanide is a non-chlorine, non-bromine chemical sanitizer. It is more stable than chlorine or bromine and has little chemical odor. Biquanide is an effective bacteriacide but, unlike chlorine and bromine, it does not destroy organic contaminants. Therefore, hydrogen peroxide is added to biguanide pools on a regular basis to eliminate organic contaminants. The optimum recommended level of biguanide is 30 to 50 ppm. APPLICATION: Swimming pools RANGE: 0–70 ppm METHOD: Biguanide complexes with the proprietary indicator to produce a colored solution. The color ranges from yellow through green to blue depending on the biguanide concentration. SAMPLE Samples should be analyzed as soon as possible. HANDLING & PRESERVATION: INTERFERENCES: The only interfering substances that are likely to be encountered in pool water are oxidized manganese and oxidizing agents, such as chlorine, bromine and ozone. Smart2 TEST PROCEDURES 2.04 Biguanide 1/2

TOLYLTRIAZOLE PROCEDURE<br />

1. Press and hold ON button until colorimeter turns on.<br />

2. Press ENTER to start.<br />

3. Press ENTER to select Testing Menu.<br />

4. Select ALL <strong>TEST</strong>S (or another sequence containing 97 T triazole<br />

from <strong>TEST</strong>ING MENU.<br />

5. Scroll to and select 97 T triazole from menu.<br />

6. Rinse a tube (0290) with sample water. Fill to 10 mL with sample.<br />

7. Insert the tube into chamber, close lid and select SCAN BLANK.<br />

8. Remove the tube from colorimeter. Discard the sample.<br />

9. Adjust the sample water temperature to between 20 and 25C if necessary.<br />

10. Fill the graduated cylinder (0417) to the 25 mL line with sample water.<br />

Transfer to the Erlenmeyer Flask (2-2109).<br />

11. Use the pH Test Paper (9259) to check the pH of the sample. If the pH is<br />

not between 4 and 6, add one drop of *Sulfuric Acid, 1.0N (6139). Swirl<br />

to mix. Continue adding *Sulfuric Acid, 1.0N (6139) one drop at a time,<br />

swirling to mix and checking the pH after each drop, until the pH is<br />

between 4 and 6.<br />

12. Add 10 drops of NaK Tartrate (7841).<br />

13. Use the 0.25 g spoon (0695) to add one measure of *Benzotriazole<br />

Reagent (3818). Swirl to mix until the powder has dissolved.<br />

14. Replace the flask in the slot in the case. Insert the Penray Lamp (31041-1)<br />

into the flask. Plug in the Penray Power Source (31041-2) and turn the<br />

lamp on for exactly 5 minutes. Remove the lamp from the flask. Rinse and<br />

wipe the lamp dry.<br />

15. Fill a test tube (0290) to the 10 mL line with the digested sample. Cap<br />

tube.<br />

16. Insert tube into chamber, close lid and select SCAN SAMPLE. Record<br />

result in ppm Tolyltriazole.<br />

17. Press OFF button to turn the colorimeter off or press EXIT button to exit<br />

to a previous menu or make another menu selection.<br />

NOTE: For best possible results, a reagent blank should be determined to<br />

account for any contribution to the test result by the reagent system. To<br />

determine the reagent blank, follow the above test procedure to scan a distilled<br />

or deionized water blank. Then follow the above procedure to perform the test<br />

on a distilled or deionized water sample. This test result is the reagent blank.<br />

Subtract the reagent blank from all subsequent test results of unknown samples.<br />

It is necessary to determine the reagent blank only when a new lot number of<br />

reagents is obtained.<br />

Benzotriazole/Tolyltriazole 4/4 Smart2 <strong>TEST</strong> PROCEDURES 7.06