<strong>RETEC</strong> <strong>Electrolytic</strong> <strong>Cells</strong><br />
Application field<br />
The <strong>RETEC</strong> <strong>Electrolytic</strong> cells have been used<br />
for metal recovery since more than 20 years.<br />
<strong>RETEC</strong> – cells are ideally suited for the<br />
recovery of gold, silver, copper, cadmium and<br />
nickel. The systems are simply designed,<br />
inexpensive and highly efficient.<br />
<strong>RETEC</strong> – cells can be installed for example<br />
next to a rinsing bath in order to reduce<br />
continuously the content of metal ions.<br />
Process Characteristics<br />
The metal ions present in the solution are<br />
reduced and deposited as metal on the<br />
surface of foamed cathodes which are made<br />
either of copper or of nickel.<br />
The cathode offers a very large effective<br />
surface. It enables an effective elimination of<br />
dissolved metal ions, even at a very low<br />
concentration (a few ppms).<br />
When one of the cell cathodes is fully charged<br />
with metal, the metallised cathode may either<br />
be sold for the metal value or used as an<br />
anode in a recycling unit.<br />
The Anodes are available in different qualities<br />
and consist of a titanium mesh covered with a<br />
noble-metal catalyst.
<strong>RETEC</strong> <strong>Electrolytic</strong> <strong>Cells</strong><br />
<strong>RETEC</strong><br />
Type<br />
02 07 6 15 25 50 CP3 CP6 CP9<br />
Useful<br />
volume [l]<br />
7 12 80 145 217 360 70 90 120<br />
Length x<br />
width [cm]<br />
27 x 32 54 x 26 55 x 55 82 x 58<br />
111 x<br />
58<br />
183 x<br />
58<br />
95 x 70 120 x 70 145 x 70<br />
Height [cm] 34 36 140 140 140 140 150 150 150<br />
Cathodes<br />
number<br />
2 7 6 15 25 50 4 7 10<br />
Cathode<br />
type<br />
Over all<br />
Type 1 Type 1 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2<br />
cathode<br />
surface [dm²]<br />
8,2 28,7 105 262,5 437,5 875 70 122,5 175<br />
Anode<br />
number<br />
3 8 7 16 26 51 3 6 9<br />
Max. current<br />
per cell [A]<br />
10 20 100 250 500 1000 180 360 540<br />
Max. voltage<br />
per cell [V]<br />
10 10 10 10 10 10 10 10 10<br />
Flow rate<br />
pump max.<br />
[l/h]<br />
600 600 1600 1600 1600 1600<br />
1340<br />
2000<br />
1340<br />
2000<br />
1340<br />
2000<br />
Special<br />
Divided Divided Divided<br />
construction<br />
chambers<br />
with<br />
chambers<br />
with<br />
chambers<br />
with<br />
membrane membrane membrane<br />
Description of plant<br />
<strong>RETEC</strong> – cells are available in different sizes and can contain from 2 up to 50 cathodes. The systems<br />
are delivered fully equipped with rectifier and easy to install.<br />
The electrolyte is introduced at one end of the cell, passes through the cell and is evacuated through an<br />
overflow at the other end. The dissolved metal in the electrolyte is deposited on the surface of the<br />
cathodes.<br />
Cathodes are available from stock in two different sizes.<br />
Type 1: 18 x 23 cm, Type 2: 46 x 38 cm, each in Cu and Ni version<br />
For pilot testing, <strong>Gütling</strong> provides the customers with rental units which allow checking of system<br />
functionality and efficiency.<br />
<strong>Gütling</strong> <strong>Wassertechnologie</strong><br />
Merowingerstraße 7<br />
D - 70736 Fellbach<br />
Tel.: + 49 (0) 711/518550 – 0<br />
Fax: + 49 (0) 711/518550 – 220<br />
www.guetling.com<br />
guetling@veoliawater.com<br />
Advantages<br />
OVERFLOW<br />
ANODE SPACER<br />
AIR DISTRIBUTOR <br />
POWER SUPPLY<br />
CATHODE<br />
• Compact design<br />
• Low invest costs<br />
• High efficiency<br />
• Reduction of water consumption and labour costs by means<br />
of extension of rinse baths life time<br />
• Reduction of chemical consumption<br />
• Reduction of sludge amount<br />
• Little floor space requirements<br />
• Pilot cells available<br />
FILTER<br />
INLET AIR<br />
INLET ELECTROLYT<br />
12/2008